Analysis of a Partial Discharge Defects in GIS Support Insulator
- 15 December 2021
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
The support insulator is one of the components with high probability of failure in GIS equipment, and the along-surface flashover and air gap defects are serious threats to the safe operation of GIS equipment. The paper proposes a method of GIS internal defect diagnosis and location based on UHF signal. Combined with the online monitoring system, the paper introduces its application process in the detection and locating of the air gap discharge of the GIS support insulator in operation. The partial discharge type is distinguished by the phase resolved partial discharge pattern recognition, and the locating of partial discharge is based on the time difference method. The disassembly analysis of GIS equipment verifies the effectiveness of the above method used by the GIS online monitoring system and avoids further development of partial discharge leading to unplanned busbar outages or serious accident. The application characteristics of partial discharge technology are analyzed in conjunction with the case study to provide reference for insulation monitoring of GIS equipment.Keywords
Funding Information
- Science and Technology Project of State Grid
This publication has 13 references indexed in Scilit:
- Quantitative comparison of partial discharge localization algorithms using time difference of arrival measurement in substationInternational Journal of Electrical Power & Energy Systems, 2019
- A Novel PD Detection Technique for Use in GIS Based on a Combination of UHF and Optical SensorsIEEE Transactions on Instrumentation and Measurement, 2018
- Effect of disconnector and high‐voltage conductor on propagation characteristics of PD‐induced UHF signalsHigh Voltage, 2018
- A Novel GIS Partial Discharge Detection Sensor With Integrated Optical and UHF MethodsIEEE Transactions on Power Delivery, 2016
- Propogation characteristics of PD‐induced UHF signal in 126 kV GIS with three‐phase construction based on time–frequency analysisIET Science, Measurement & Technology, 2016
- New aspects of UHF PD diagnostics on gas-insulated systemsIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Performance Comparison of Typical Built-In UHF Sensors Used for GIS PD DetectionApplied Mechanics and Materials, 2014
- Investigation on the placement effect of UHF sensor and propagation characteristics of PD-induced electromagnetic wave in GIS based on FDTD methodIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Partial discharge measurement and pattern recognition in gas insulated switchgear2011
- Research on the Typical Partial Discharge Using the UHF Detection Method for GISIEEE Transactions on Power Delivery, 2011