Tianxin Zhuang
Tianxin Zhuang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Ming Dong
3 shared publications- Ming Ren
Xi’an Jiaotong University
3 shared publications Chongxing Zhang
2 shared publications- Ming Dong
Xi’an Jiaotong University
2 shared publications Ming Ren
Xi'an Jiaotong University, State Key Laboratory of Electrical Insulation for Power Equipment, Xi'an, 710049, China
2 shared publications- Bin Wang
State Key Laboratory of Electrical Insulation for Power Equipment Xi'an Jiaotong University Xianning Road 28th Xi'an People's Republic of China
1 shared publication
Latest Publications
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of a Partial Discharge Defects in GIS Support Insulator
The support insulator is one of the components with high probability of failure in GIS equipment, and the along-surface flashover and air gap defects are serious threats to the safe operation of GIS equipment. The paper proposes a method of GIS internal defect diagnosis and location based on UHF signal. Combined with the online monitoring system, the paper introduces its application process in the detection and locating of the air gap discharge of the GIS support insulator in operation. The partial discharge type is distinguished by the phase resolved partial discharge pattern recognition, and the locating of partial discharge is based on the time difference method. The disassembly analysis of GIS equipment verifies the effectiveness of the above method used by the GIS online monitoring system and avoids further development of partial discharge leading to unplanned busbar outages or serious accident. The application characteristics of partial discharge technology are analyzed in conjunction with the case study to provide reference for insulation monitoring of GIS equipment.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of a Partial Discharge Defects in GIS Support Insulator
The support insulator is one of the components with high probability of failure in GIS equipment, and the along-surface flashover and air gap defects are serious threats to the safe operation of GIS equipment. The paper proposes a method of GIS internal defect diagnosis and location based on UHF signal. Combined with the online monitoring system, the paper introduces its application process in the detection and locating of the air gap discharge of the GIS support insulator in operation. The partial discharge type is distinguished by the phase resolved partial discharge pattern recognition, and the locating of partial discharge is based on the time difference method. The disassembly analysis of GIS equipment verifies the effectiveness of the above method used by the GIS online monitoring system and avoids further development of partial discharge leading to unplanned busbar outages or serious accident. The application characteristics of partial discharge technology are analyzed in conjunction with the case study to provide reference for insulation monitoring of GIS equipment.
- 4 September 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (48) , 485302
Excess conduction induced by partial discharge in polymer
The classical dipole model of partial discharge (PD) explains the relationship between the internal pulse charge and detected charge on the terminal, which is essential to assess the PD severity. However, the subsequent behavior (such as transport and dissipation) of the deposited charges generated during the PD process is still uncertain, which is likely to be an inducement in the degradation of the dielectrics. Some earlier studies tried to separate the movement of the deposited charge from the PD-induced current, but its kinetics still remain unclear. In this work, a measurement is designed to acquire the charge deposited during PDs under an alternating-electric field at low temperatures, giving insight into the subsequent behavior of PDs on epoxy films. Then, a charge transport model is established to explain the observed charge movement, according to which the dissipation of the deposited charges is explained as an excess conduction phenomenon during PDs and is affected by temperature. This excess conduction releases a part of the space charge accumulated in the polymers, but causes an excess conduction loss beyond bulk dielectric loss, which is regarded as an abnormal aging inducement. While at low temperature, excess conduction is suppressed, and trapped charges become a critical factor for degradation.
- 4 September 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (48) , 485302
Excess conduction induced by partial discharge in polymer
The classical dipole model of partial discharge (PD) explains the relationship between the internal pulse charge and detected charge on the terminal, which is essential to assess the PD severity. However, the subsequent behavior (such as transport and dissipation) of the deposited charges generated during the PD process is still uncertain, which is likely to be an inducement in the degradation of the dielectrics. Some earlier studies tried to separate the movement of the deposited charge from the PD-induced current, but its kinetics still remain unclear. In this work, a measurement is designed to acquire the charge deposited during PDs under an alternating-electric field at low temperatures, giving insight into the subsequent behavior of PDs on epoxy films. Then, a charge transport model is established to explain the observed charge movement, according to which the dissipation of the deposited charges is explained as an excess conduction phenomenon during PDs and is affected by temperature. This excess conduction releases a part of the space charge accumulated in the polymers, but causes an excess conduction loss beyond bulk dielectric loss, which is regarded as an abnormal aging inducement. While at low temperature, excess conduction is suppressed, and trapped charges become a critical factor for degradation.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (8) , 5345-5355
Automatic Fault Diagnosis of Infrared Insulator Images Based on Image Instance Segmentation and Temperature Analysis
As an onsite condition monitoring method, infrared inspection can help to discover and analyze abnormal temperature increases in power equipment. To improve the efficiency of onsite diagnosis of insulators in substations, this paper proposes an automatic diagnosis method using instance segmentation and temperature analysis of infrared insulator images. To develop this method, thousands of infrared images from field inspection databases were collected to establish an annotated data set of insulator images. With the aid of Mask R-CNN it was possible to extract multiple insulators automatically in the infrared images. Transfer learning as well as the dynamic learning rate algorithm were then employed to realize the training process of Mask R-CNN with the annotated image data set. The result of the testing experiment showed that the mAP of the model is 0.77 and the FPS is 5.07, which indicated great identification accuracy and computing speed of the proposed model. Next, function fitting was realized to extract the temperature distribution of each insulator. Finally, to evaluate the condition of each insulator, rules, which are based on the related standards, were established using machine language. This is the first time that the machine could independently realize fault analysis of multiple insulators in the infrared images, which is a great attempt to adapt the development of the Internet of Things and the tendency of predictive maintenance. Moreover, because of the universality of the model algorithm used, automatic infrared fault diagnosis for other power equipment could also be performed in a similar manner, which has significant potential applicability in the area of power equipment diagnosis.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (8) , 5345-5355
Automatic Fault Diagnosis of Infrared Insulator Images Based on Image Instance Segmentation and Temperature Analysis
As an onsite condition monitoring method, infrared inspection can help to discover and analyze abnormal temperature increases in power equipment. To improve the efficiency of onsite diagnosis of insulators in substations, this paper proposes an automatic diagnosis method using instance segmentation and temperature analysis of infrared insulator images. To develop this method, thousands of infrared images from field inspection databases were collected to establish an annotated data set of insulator images. With the aid of Mask R-CNN it was possible to extract multiple insulators automatically in the infrared images. Transfer learning as well as the dynamic learning rate algorithm were then employed to realize the training process of Mask R-CNN with the annotated image data set. The result of the testing experiment showed that the mAP of the model is 0.77 and the FPS is 5.07, which indicated great identification accuracy and computing speed of the proposed model. Next, function fitting was realized to extract the temperature distribution of each insulator. Finally, to evaluate the condition of each insulator, rules, which are based on the related standards, were established using machine language. This is the first time that the machine could independently realize fault analysis of multiple insulators in the infrared images, which is a great attempt to adapt the development of the Internet of Things and the tendency of predictive maintenance. Moreover, because of the universality of the model algorithm used, automatic infrared fault diagnosis for other power equipment could also be performed in a similar manner, which has significant potential applicability in the area of power equipment diagnosis.
- 29 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 26 (3) , 955-963
Slow current induced by partial discharge in kapton, epoxy and PET
An earlier study focused on the stochastic features of PD in terms of phase or time-resolved statistics and the mechanisms underlying the various phases of PD including inception, propagation and extinction in the movement of the low-frequency charge along the polymer, which exists during and after PD. This subsequent effect can account for in part the abnormal space charge accumulation, dielectric loss and electric field distortion. This paper presents a first attempt to observe the slow current flow induced by PD and describes its dynamics along different polymer films under AC electric field. We designed a measurement system to acquire the slow current component by cancelling the displacement current, intrinsic conduction current and the transferred PD current from the total current flow. It is shown that the PD-transferred charge is independent on the polymer material while the PD-induced slow current is the opposite and presents a stepped variation with applied electric field. To understand the findings, the trap depth, trap density and carrier mobility of each polymer film were measured, and the surface current is not measured through the grounded guard electrode. The bulk slow current is found to be closely related to the trap parameters and mobility of the dielectric. A preliminary model considering space charge and driven by electric field is proposed which may facilitate the understanding and analysis of the complicated charges dynamics during PD at AC electric field. The relationship between the heat by slow current and the degradation of dielectric is discussed.
- 29 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 26 (3) , 955-963
Slow current induced by partial discharge in kapton, epoxy and PET
An earlier study focused on the stochastic features of PD in terms of phase or time-resolved statistics and the mechanisms underlying the various phases of PD including inception, propagation and extinction in the movement of the low-frequency charge along the polymer, which exists during and after PD. This subsequent effect can account for in part the abnormal space charge accumulation, dielectric loss and electric field distortion. This paper presents a first attempt to observe the slow current flow induced by PD and describes its dynamics along different polymer films under AC electric field. We designed a measurement system to acquire the slow current component by cancelling the displacement current, intrinsic conduction current and the transferred PD current from the total current flow. It is shown that the PD-transferred charge is independent on the polymer material while the PD-induced slow current is the opposite and presents a stepped variation with applied electric field. To understand the findings, the trap depth, trap density and carrier mobility of each polymer film were measured, and the surface current is not measured through the grounded guard electrode. The bulk slow current is found to be closely related to the trap parameters and mobility of the dielectric. A preliminary model considering space charge and driven by electric field is proposed which may facilitate the understanding and analysis of the complicated charges dynamics during PD at AC electric field. The relationship between the heat by slow current and the degradation of dielectric is discussed.
- 22 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1706-1714
Insulation Condition Monitoring in Distribution Power Grid via IoT-Based Sensing Network
Insulation condition monitoring is essential for the safety of our distribution power gird. However, the traditional monitoring solution is hardly applied due to the concerns arise from natures of distribution grid, such as complex feeder networks, massive operation site and high economic benefit. In this paper, a wireless sensing network based on IoT technology is demonstrated for insulation condition perception. First of all, the general framework of the wireless sensing network is designed with considerations on extendibility and accessibility. Next, it goes into detail about the technical requirements of the essential units of the sensing network including sensor node, power management and data communication. With this concept, two practical cases of IoT-based partial discharge sensing networks realized on the switchgear cabinet and power cable are presented with details involving the design of TEV and HFCT sensor nodes, the energy consumption, Lora/NB-IoT-based network structures and data usage strategies. This IoT-based insulation condition monitoring is proven to be applicable for the distribution grid and expected to be references for more possible IoT applications.
- 22 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1706-1714
Insulation Condition Monitoring in Distribution Power Grid via IoT-Based Sensing Network
Insulation condition monitoring is essential for the safety of our distribution power gird. However, the traditional monitoring solution is hardly applied due to the concerns arise from natures of distribution grid, such as complex feeder networks, massive operation site and high economic benefit. In this paper, a wireless sensing network based on IoT technology is demonstrated for insulation condition perception. First of all, the general framework of the wireless sensing network is designed with considerations on extendibility and accessibility. Next, it goes into detail about the technical requirements of the essential units of the sensing network including sensor node, power management and data communication. With this concept, two practical cases of IoT-based partial discharge sensing networks realized on the switchgear cabinet and power cable are presented with details involving the design of TEV and HFCT sensor nodes, the energy consumption, Lora/NB-IoT-based network structures and data usage strategies. This IoT-based insulation condition monitoring is proven to be applicable for the distribution grid and expected to be references for more possible IoT applications.
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (13) , 5532-5540
Optical Partial Discharge Diagnosis in SF6 Gas-Insulated System With SiPM-Based Sensor Array
This paper aims to promote optical partial discharge (PD) detection from laboratory scale to practical application for sulfur hexafluoride (SF6)-insulated power equipment. Firstly, a micro silicon photomultiplier (SiPM)-based PD sensor is evaluated for detecting PDs in SF6 gas and is proven to have the equivalent properties with pulse current acquisition and vacuum photomultiplier tube (PMT) in terms of the signal-to-noise ratio (SNR), pulse resolution and linearity. Then, a double-spectral PD sensor based on SiPM is first proposed and developed to realize a more specific PD diagnosis. It is demonstrated that by using the double-spectral PD sensor not only stochastic PD patterns can be obtained for PD recognition, but PD severity can be estimated as well.
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (13) , 5532-5540
Optical Partial Discharge Diagnosis in SF6 Gas-Insulated System With SiPM-Based Sensor Array
This paper aims to promote optical partial discharge (PD) detection from laboratory scale to practical application for sulfur hexafluoride (SF6)-insulated power equipment. Firstly, a micro silicon photomultiplier (SiPM)-based PD sensor is evaluated for detecting PDs in SF6 gas and is proven to have the equivalent properties with pulse current acquisition and vacuum photomultiplier tube (PMT) in terms of the signal-to-noise ratio (SNR), pulse resolution and linearity. Then, a double-spectral PD sensor based on SiPM is first proposed and developed to realize a more specific PD diagnosis. It is demonstrated that by using the double-spectral PD sensor not only stochastic PD patterns can be obtained for PD recognition, but PD severity can be estimated as well.