Wouter B. J. Hakvoort
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wouter B. J. Hakvoort has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
André de Boer
Applied Mechanics Laboratory, Faculty of Engineering Technology, University of Twente, P.O. Box 217, Enschede 7500AE, The Netherlands
1 shared publicationJohannes van Dijk
Mechanical Automation Laboratory, Faculty of Engineering Technology, University of Twente, P.O. Box 217, Enschede 7500AE, The Netherlands
1 shared publicationJoost C. Lötters
MESA+ Institute for Nanotechnology, University of Twente, Enschede 7500AE, The Netherlands
1 shared publication- Jos Ansink
DEMCON Advanced Mechatronics
1 shared publication - L. van de Ridder
Mechanical Automation Laboratory, Faculty of Engineering Technology, University of Twente, P.O. Box 217, Enschede 7500AE, The Netherlands
1 shared publication
Latest Publications
- 12 January 2016
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 138 (3) , 031005
Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
In this paper, a vibration isolated design of a Coriolis mass-flow meter (CMFM) is proposed by introducing a compliant connection between the casing and the tube displacement sensors, with the objective to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of external vibrations. The transfer from external vibrations to the relative displacement measurement is analyzed and the design is optimized to minimize this transfer. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimized. The optimal tuning of the parameters is done actively by acceleration feedback. Based on simulation results, a prototype is built and validated. The validated design shows more than 24 dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.
- 12 January 2016
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 138 (3) , 031005
Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
In this paper, a vibration isolated design of a Coriolis mass-flow meter (CMFM) is proposed by introducing a compliant connection between the casing and the tube displacement sensors, with the objective to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of external vibrations. The transfer from external vibrations to the relative displacement measurement is analyzed and the design is optimized to minimize this transfer. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimized. The optimal tuning of the parameters is done actively by acceleration feedback. Based on simulation results, a prototype is built and validated. The validated design shows more than 24 dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.
- 29 October 2011
- Published by Springer Nature
- p. 163-173
Integration of an Automated Order-Picking System
- 29 October 2011
- Published by Springer Nature
- p. 163-173
Integration of an Automated Order-Picking System