Influence of the Arterial Input Function on Absolute and Relative Perfusion-Weighted Imaging Penumbral Flow Detection
- 1 February 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 43 (2) , 378-385
Abstract
Background and Purpose—: Perfusion-weighted imaging maps are used to identify critical hypoperfusion in acute stroke. However, quantification of perfusion may depend on the choice of the arterial input function (AIF). Using quantitative positron emission tomography we evaluated the influence of the AIF location on maps of absolute and relative perfusion-weighted imaging to detect penumbral flow (PF; CBF ) in acute stroke. Methods—: In 22 patients with acute stroke the AIF was placed at 7 sites (M1, M2, M3 ipsi- and contralateral and internal carotid artery–M1 contralateral to the infarct). Comparative 15 O-water positron emission tomography and AIF-dependent perfusion-weighted imaging (cerebral blood flow, cerebral blood volume, mean transit time, and time to maximum) were performed. A receiver operating characteristic curve analysis described the threshold independent performance (area under the curve) of the perfusion-weighted maps for all 7 AIF locations and identified the best AIF-dependent absolute and relative thresholds to identify PF. These results were compared with AIF-independent time-to-peak maps. Results—: Quantitative perfusion-weighted imaging maps of cerebral blood flow and time to maximum performed best. For PF detection, AIF placement did significantly influence absolute PF thresholds. However, AIF placement did not influence (1) the threshold independent performance; and (2) the relative PF thresholds. AIF placement in the proximal segment of the contralateral middle cerebral artery (cM1) was preferable for quantification. Conclusions—: AIF-based maps of cerebral blood flow and time to maximum were most accurate to detect the PF threshold. The AIF placement significantly altered absolute PF thresholds and showed best agreement with positron emission tomography for the cM1 segment. The performance of relative PF thresholds, however, was not AIF location-dependent and might be along with AIF-independent time-to-peak maps, more suitable than absolute PF thresholds in acute stroke if detailed postprocessing is not feasible.Keywords
This publication has 22 references indexed in Scilit:
- Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: Definitions and thresholdsAnnals of Neurology, 2011
- Improving the accuracy of perfusion imaging in acute ischemic strokeAnnals of Neurology, 2011
- Maps of Time to Maximum and Time to Peak for Mismatch Definition in Clinical Stroke Studies Validated With Positron Emission TomographyStroke, 2010
- A Simple Positron Emission Tomography-Based Calibration for Perfusion-Weighted Magnetic Resonance Maps to Optimize Penumbral Flow Detection in Acute StrokeStroke, 2010
- MRI Perfusion Maps in Acute Stroke Validated With 15O-Water Positron Emission TomographyStroke, 2010
- Reliable Perfusion Maps in Stroke MRI Using Arterial Input Functions Derived From Distal Middle Cerebral Artery BranchesStroke, 2010
- Comparison of 10 Perfusion MRI Parameters in 97 Sub-6-Hour Stroke Patients Using Voxel-Based Receiver Operating Characteristics AnalysisStroke, 2009
- Perfusion MRI (Tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patientsNeurology, 2009
- How Reliable Is Perfusion MR in Acute Stroke?Stroke, 2008
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996