The relationship between different pulse wave velocity and systolic/diastolic pressure
Authors:
- 1 June 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21562318,p. 1185-1190
Abstract
Blood pressure is an important indication of whether the cardiovascular system is in healthy state. In order to continuously measure the non-invasive blood pressure using pulse wave velocity, different pulse wave velocities respective to systolic pressure and diastolic pressure must be studied. In this paper, instead of using ECG together with one pulse wave, two independent pulse waves (one from ear and the other from toe) are acquired using optical sensors. Their time-relationships are studied by pulse contour analysis in order to deeply understand the pulse wave propagation and reflection in arterial system. Then we propose the ways to determine the PWVs relative to systolic/diastolic blood pressure (SBP/DBP) respectively. Real PWVs data relative to DBP/SBP in normal and hypertension conditions are obtained experimentally. By studying these data we can find out the causes of hypertension and some relationship between BP and PWV. We also point out that there is uniform variation law exists between PWV and DBP/ SBP. This implies the possibility of calculating SBP and DBP based on only one mathematical model.Keywords
This publication has 16 references indexed in Scilit:
- Pulse Morphology Visualization and Analysis With Applications in Cardiovascular Pressure SignalsIEEE Transactions on Biomedical Engineering, 2007
- Modeling of Pulse Transit Time under the Effects of Hydrostatic Pressure for Cuffless Blood Pressure Measurements2006
- An Evaluation of a PTT-Based Method for Noninvasive and Cuffless Estimation of Arterial Blood Pressure2006
- Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period2006
- Continuous Cardiac Output Monitoring by Peripheral Blood Pressure Waveform AnalysisIEEE Transactions on Biomedical Engineering, 2006
- A method to determine diastolic blood pressure based on pressure pulse propagation in the electronic palpation method2005
- Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time2005
- Calibration of the Photoplethysmogram to Arterial Blood Pressure: Capabilities and Limitations for Continuous Pressure Monitoring2005
- Validation of a noninvasive blood pressure monitoring device in normotensive and hypertensive pediatric intensive care patientsJournal of Clinical Monitoring and Computing, 2004
- Relationships ol Pulse Transmission Times to Pre‐ejection Period and Blood PressurePsychophysiology, 1981