An ion-imaging detector for high count rates
Open Access
- 1 June 2025
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Abstract
The emergence of high-power ionizing light sources with repetition rates greater than 100 kHz promises vastly improved data acquisition times for electron and ion imaging experiments; however, optimal means to record ion images at high average ion flux are challenging. A popular ion imaging detector uses a double (chevron) microchannel plate (MCP) stack operating at high gain (∼106) and a phosphor screen floated to 4 kV while images are recorded using a CCD or CMOS camera. Such imaging detectors tend to exhibit severe inhomogeneity at high incidence ion flux due to saturation effects in the MCP, even when the amplified current is far below the strip-current limit. This inhomogeneity arises from a local loss of gain in channels experiencing a high frequency of ion-amplification events, even when most channels are behaving normally. Here, we describe an alternative ion imaging scheme using a detector based on a single microchannel plate, a phosphor screen that can be floated to 20 kV, and a Timepix3 based event camera and demonstrate its performance in an ion-imaging experiment performed at a repetition rate of 100 kHz. The reduced gain of the single MCP avoids gain inhomogeneity up to higher count-rates, while the high-voltage phosphor helps maintain high single ion detection efficiency. The detector performs well at an ion flux of 107 ions cm−2 s−1.Keywords
Funding Information
- HORIZON EUROPE European Research Council (833404)
- Deutsche Forschungsgemeinschaft (389479699/GRK2455)
This publication has 19 references indexed in Scilit:
- Spatial extension of the transient gain drop in a microchannel plate for a single-pulse irradiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024
- Evaluation of transient gain-drop and following recovery property on microchannel plate: Comparison between two evaluation methodsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023
- Microchannel plate response to high-intensity ion bunchesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Slice imaging: A new approach to ion imaging and velocity mappingReview of Scientific Instruments, 2001
- Improved two-dimensional product imaging: The real-time ion-counting methodReview of Scientific Instruments, 1998
- Velocity map imaging of ions and electrons using electrostatic lenses: Application in photoelectron and photofragment ion imaging of molecular oxygenReview of Scientific Instruments, 1997
- The operation of microchannel plates at high count ratesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- Microchannel plate detectorsNuclear Instruments and Methods, 1979
- Saturation in Continuous Channel Electron MultipliersReview of Scientific Instruments, 1971
- Continuous Channel Electron MultiplierReview of Scientific Instruments, 1962