Alice Bremer
Research Subjects
Alice Bremer has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alec M. Wodtke
Institute for Physical Chemistry, Georg-August University of Göttingen, Germany
1 shared publication - Daniel J. Auerbach
Department of Dynamics at Surfaces, Max Planck Institute for Multidisciplinary Sciences, Am Faßberg 11, Goettingen, Germany
1 shared publication - Florian Nitz
Institute for Physical Chemistry, Georg-August University of Goettingen, Tammannstraße 6, Goettingen, Germany
1 shared publication - Kai Golibrzuch
Max Planck Institute for Multidisciplinary Sciences 2 , Am Faßberg 11, Göttingen 37077
1 shared publication - Mark E. Bernard
Department of Chemistry, University of Virgina , Charlottesville, Virginia 22904
1 shared publication - Stefan Hörandl
Institute for Physical Chemistry, Georg-August University of Goettingen 1 , Tammannstraße 6, 37077 Goettingen
1 shared publication
Latest Publications
- Open Access
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
An ion-imaging detector for high count rates
The emergence of high-power ionizing light sources with repetition rates greater than 100 kHz promises vastly improved data acquisition times for electron and ion imaging experiments; however, optimal means to record ion images at high average ion flux are challenging. A popular ion imaging detector uses a double (chevron) microchannel plate (MCP) stack operating at high gain (∼106) and a phosphor screen floated to 4 kV while images are recorded using a CCD or CMOS camera. Such imaging detectors tend to exhibit severe inhomogeneity at high incidence ion flux due to saturation effects in the MCP, even when the amplified current is far below the strip-current limit. This inhomogeneity arises from a local loss of gain in channels experiencing a high frequency of ion-amplification events, even when most channels are behaving normally. Here, we describe an alternative ion imaging scheme using a detector based on a single microchannel plate, a phosphor screen that can be floated to 20 kV, and a Timepix3 based event camera and demonstrate its performance in an ion-imaging experiment performed at a repetition rate of 100 kHz. The reduced gain of the single MCP avoids gain inhomogeneity up to higher count-rates, while the high-voltage phosphor helps maintain high single ion detection efficiency. The detector performs well at an ion flux of 107 ions cm−2 s−1.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Open AccessAn ion-imaging detector for high count rates
The emergence of high-power ionizing light sources with repetition rates greater than 100 kHz promises vastly improved data acquisition times for electron and ion imaging experiments; however, optimal means to record ion images at high average ion flux are challenging. A popular ion imaging detector uses a double (chevron) microchannel plate (MCP) stack operating at high gain (∼106) and a phosphor screen floated to 4 kV while images are recorded using a CCD or CMOS camera. Such imaging detectors tend to exhibit severe inhomogeneity at high incidence ion flux due to saturation effects in the MCP, even when the amplified current is far below the strip-current limit. This inhomogeneity arises from a local loss of gain in channels experiencing a high frequency of ion-amplification events, even when most channels are behaving normally. Here, we describe an alternative ion imaging scheme using a detector based on a single microchannel plate, a phosphor screen that can be floated to 20 kV, and a Timepix3 based event camera and demonstrate its performance in an ion-imaging experiment performed at a repetition rate of 100 kHz. The reduced gain of the single MCP avoids gain inhomogeneity up to higher count-rates, while the high-voltage phosphor helps maintain high single ion detection efficiency. The detector performs well at an ion flux of 107 ions cm−2 s−1.