KGKai Golibrzuch

Kai Golibrzuch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kai Golibrzuch has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A sensitive method for determining dehydrogenation probabilities at a metal surface

    by Behrouz Sabour, Bayenah O. Al-Shami, Johannes V. Diedrich, Kai Golibrzuch, Dmitriy Borodin, Theofanis Kitsopoulos, Tim Schäfer, G. Barratt Park

    We report a sensitive new approach for tracking surface hydrogen coverage using the novel high-repetition rate implementation of velocity-resolved kinetics in an investigation of methanol-d4 dehydrogenation on Pt(111) to CO and D2. The reactant beam of methanol-d4 had an incidence kinetic energy of 0.46 eV, and the reaction was studied over a surface temperature range of 700–950 K. The reaction probability of methanol dehydrogenation was determined by probing the second-order reaction kinetics of D2 and HD formation, which is directly correlated to the surface hydrogen coverage. Under the conditions of our study, the methanol dehydrogenation probability was found to be low (∼10−3), and the lack of strong temperature dependence is consistent with dehydrogenation via a direct mechanism. Under conditions that favored methanol clustering in the incident methanol beam, the dehydrogenation probability increases significantly at low surface temperatures, which suggests a precursor-mediated mechanism. The possible role of cluster formation in enhancing the trapping probability of methanol is discussed.

  • Open Access

    An ion-imaging detector for high count rates

    by Kai Golibrzuch, Florian Nitz, Stefan Hörandl, Mark E. Bernard, Alice Bremer, Daniel J. Auerbach, Theofanis N. Kitsopoulos, Alec M. Wodtke

    The emergence of high-power ionizing light sources with repetition rates greater than 100 kHz promises vastly improved data acquisition times for electron and ion imaging experiments; however, optimal means to record ion images at high average ion flux are challenging. A popular ion imaging detector uses a double (chevron) microchannel plate (MCP) stack operating at high gain (∼106) and a phosphor screen floated to 4 kV while images are recorded using a CCD or CMOS camera. Such imaging detectors tend to exhibit severe inhomogeneity at high incidence ion flux due to saturation effects in the MCP, even when the amplified current is far below the strip-current limit. This inhomogeneity arises from a local loss of gain in channels experiencing a high frequency of ion-amplification events, even when most channels are behaving normally. Here, we describe an alternative ion imaging scheme using a detector based on a single microchannel plate, a phosphor screen that can be floated to 20 kV, and a Timepix3 based event camera and demonstrate its performance in an ion-imaging experiment performed at a repetition rate of 100 kHz. The reduced gain of the single MCP avoids gain inhomogeneity up to higher count-rates, while the high-voltage phosphor helps maintain high single ion detection efficiency. The detector performs well at an ion flux of 107 ions cm−2 s−1.


  • Open Access

    Multi-mass velocity-resolved kinetics of surface reactions at 100 kHz acquisition rate

    by Florian Nitz, Stefan Hörandl, Kai Golibrzuch, Dmitriy Borodin, Georgios Skoulatakis, Alexander Kandratsenka, Dirk Schwarzer, Theofanis N. Kitsopoulos, Daniel J. Auerbach, Alec M. Wodtke

    Velocity-resolved kinetics (VRK) employs a pulsed molecular beam that initiates reactions at a surface and a pulsed ionization-laser that detects desorbed products, exploiting ion-imaging-based, velocity-sensitive detection to derive the product-flux vs reaction time. In its original form, kinetics was observed by scanning the delay between the molecular beam and laser while obtaining ion-images for ions with a single mass-to-charge ratio (m/q). Here, we demonstrate a dramatically improved version of VRK, where data are obtained quasi-continuously with a 100 kHz ionization laser and an event camera based on CERN Timepix3 technology (Amsterdam Scientific Instruments TPX3CAM). This improved version provides the full temporal behavior of the reaction products for every molecular beam pulse, resulting in a duty cycle advantage ranging from ≈ 300 to 105 in the examples given. Furthermore, the new technique allows us to simultaneously follow the kinetics of multiple species with different m/q by using the event camera’s ability to provide pixel-specific timestamps. Data for three example systems, hydrogen atom recombination, hydrogen oxidation, and ammonia oxidation on Pt(332), illustrate the improvements in the acquisition rate and signal-to-noise ratio obtained. We also show that it is possible to extend the application of the VRK technique to non-stationary catalysts.


  • Resonance-enhanced multiphoton ionization detection of vibrationally excited O2

    by Itai S. Kallos, Kerim Benfreha, Kai Golibrzuch, Hao Zhao, Ilana Bar, Tim Schäfer, Igor Rahinov, Alec M. Wodtke, Joshua H. Baraban

    We report a rotationally resolved spectroscopic detection scheme for vibrationally excited molecular oxygen with high sensitivity. Two-color (2 + 1′) resonance-enhanced multiphoton ionization (REMPI) spectra of O2 hot bands were recorded for the first time via the 3dπ(v′=0)←X3Σg− (v″ = 1) Rydberg transitions. Spectroscopic constants and relative Franck–Condon factors were extracted and compared to simulations. This new access to quantum-state-resolved diagnostics of vibrationally excited O2 promises to shed light on the physical and chemical dynamics of many processes.


  • Open Access

    A simple cavity-enhanced laser-based heater for reflective samples

    by Kai Golibrzuch, Alec M. Wodtke

    Surface science instruments require excellent vacuum to ensure surface cleanliness; they also require control of sample temperature, both to clean the surface of contaminants and to control reaction rates at the surface, for example, for molecular beam epitaxy and studies of heterogeneous catalysis. Standard approaches to sample heating within high vacuum chambers involve passing current through filaments of refractory metals, which then heat the sample by convective, radiative, or electron bombardment induced heat transfer. Such hot filament methods lead to outgassing of molecules from neighboring materials that are inadvertently heated; they also produce electrons and ions that may interfere with other aspects of the surface science experiment. Hot filaments may even disintegrate when used in the presence of gases introduced to induce surface reactions on the sample. Optical heating using lasers can deliver energy directly to the sample, ensuring that only the sample is heated and surroundings within the vacuum chamber are not, while simultaneously eliminating the need for hot filaments. Despite this advantage, optical heating is not commonly employed—such methods are considered complex, expensive, and unreliable. More fundamentally, surface scientists are often interested in metallic samples, whose reflectivity may limit the efficiency of laser heating. In this paper, we describe a simple and inexpensive sample heater based on a commercial diode laser, whose heating efficiency is enhanced by a concave aluminum mirror placed behind the sample. The geometry of the reflector and sample ensures that a stable optical cavity is produced. Using only 26 W of laser power directed to the sample with a fiber optic, a 1-cm diameter × 2-mm thick Pt sample could be heated to 1400 K within 1 min. Excellent programmable temperature control and long-term temperature stability are also demonstrated. Sample heating to 900 °C was performed with negligible increase in chamber pressure. The entire setup comprises components costing less than typical electron bombardment heaters.


  • Open Access

    Erratum: “Quantum and classical molecular dynamics for H atom scattering from graphene” [J. Chem. Phys. 159, 194102 (2023)]

    by Lei Shi, Markus Schröder, Hans-Dieter Meyer, Daniel Peláez, Alec M. Wodtke, Kai Golibrzuch, Anna-Maria Schönemann, Alexander Kandratsenka, Fabien Gatti

    In our article,1 Fig. 12 was inadvertently mixed with other results. The correct figure should be as follows (Fig. 1). In our article,1 Fig. 12 was inadvertently mixed with other results. The correct figure should be as follows (Fig. 1).


  • Open Access

    Quantum and classical molecular dynamics for H atom scattering from graphene

    by Lei Shi, Markus Schröder, Hans-Dieter Meyer, Daniel Peláez, Alec M. Wodtke, Kai Golibrzuch, Anna-Maria Schönemann, Alexander Kandratsenka, Fabien Gatti

    This work presents systematic comparisons between classical molecular dynamics (cMD) and quantum dynamics (QD) simulations of 15-dimensional and 75-dimensional models in their description of H atom scattering from graphene. We use an experimentally validated full-dimensional neural network potential energy surface of a hydrogen atom interacting with a large cell of graphene containing 24 carbon atoms. For quantum dynamics simulations, we apply Monte Carlo canonical polyadic decomposition to transform the original potential energy surface (PES) into a sum of products form and use the multi-layer multi-configuration time-dependent Hartree method to simulate the quantum scattering of a hydrogen or deuterium atom with an initial kinetic energy of 1.96 or 0.96 eV and an incident angle of 0°, i.e., perpendicular to the graphene surface. The cMD and QD initial conditions have been carefully chosen in order to be as close as possible. Our results show little differences between cMD and QD simulations when the incident energy of the H atom is equal to 1.96 eV. However, a large difference in sticking probability is observed when the incident energy of the H atom is equal to 0.96 eV, indicating the predominance of quantum effects. To the best of our knowledge, our work provides the first benchmark of quantum against classical simulations for a system of this size with a realistic PES. Additionally, new projectors are implemented in the Heidelberg multi-configuration time-dependent Hartree package for the calculation of the atom scattering energy transfer distribution as a function of outgoing angles.


  • Open Access

    Generation of Sub-nanosecond H Atom Pulses for Scattering from Single-Crystal Epitaxial Graphene

    by Kai Golibrzuch, Victoria Walpole, Anna-Maria Schönemann, Alec M. Wodtke

    Pulsed molecular beams allow high-density gas samples to be cooled to low internal temperatures and to produce narrow speed distributions. They are particularly useful in combination with pulsed-laser-based detection schemes and have also been used as pump pulses in pump-probe experiments with neutral matter. The mechanical response of pulsed valves and chopper wheels limits the duration of these pulses typically to about 10-100 mu s. Bunch compression photolysis has been proposed as a means to produce atomic pulses shorter than 1 ns-an experimental capability that would allow new measurements to be made on chemical systems. This technique employs a spatially chirped femtosecond duration photolysis pulse that produced an ensemble of H atom photoproducts that rebunches into a short pulse downstream. To date, this technique could not produce strong enough beams to allow new experiments to be carried out. In this paper, we report production of pulsed H atom beams consistent with a 700 ps pulse duration and with sufficient intensity to carry out differentially resolved inelastic H scattering experiments from a graphene surface. We observe surprisingly narrow angular distributions for H atoms incident normal to the surface. At low incidence energies quasi-elastic scattering dominates, and at high incidence energy we observe a strongly inelastic scattering channel. These results provide the basis for future experiments where the H atoms synchronously collide with a pulsed-laser-excited surface.


  • Cover Picture: Velocity‐resolved Laser‐induced Desorption for Kinetics on Surface Adsorbates (Chem. Methods 5/2022)

    by Kim Papendorf, Kai Golibrzuch, Tianli Zhong, Sven Schwabe, Theofanis N. Kitsopoulos, Alec M. Wodtke

  • Velocity‐resolved Laser‐induced Desorption for Kinetics on Surface Adsorbates

    by Kim Pappendorf, Kai Golibrzuch, Tian‐Li Zhong, Sven Schwabe, Theofanis Kitsopoulos, Alec M. Wodtke

    Invited for this month's cover are the groups of Alec M. Wodtke at the Georg‐August University in Göttigen (Germany) and at the University of Crete (Greece). The cover picture shows ammonia (NH3) molecules adsorbed on an atomically flat platinum surface. An ultra‐short laser pulse hits the surface and heats up the metal electron rapidly to several thousand Kelvin within a few 100 fs. This high electronic temperature causes a fraction of the ammonia molecules to desorb with hyperthermal velocity from the surface. Depended on the laser intensity, the number of desorbing molecules is proportional to the surface coverage. Read the full text of their Research Article at 10.1002/cmtd.202200017.