A novel and low-complexity peak detection algorithm for heart rate estimation from low-amplitude photoplethysmographic (PPG) signals
- 17 November 2018
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (8) , 569-577
Abstract
Low-amplitude PPG signals are more affected by noise contamination and other undesirable effects because the signal strength is comparable to noise power. Although several authors claim that decreases in the amplitude of the PPG wave should be addressed from signal acquisition and conditioning stages such decreases can also be associated with changes in the patient condition. In that instance, it is important to ensure continuous and reliable HR monitoring which, in turn, depends on how robust is the peak detection method. Numerous efforts have been made to develop algorithms for accurate PPG peak detection under high motion artefact conditions. However, little has been done regarding peak detection in low-amplitude PPG signals. In an attempt to address this issue, a novel and simple peak detection algorithm for PPG signals was proposed. Results show that our method could be a good contribution for robust strategies that can dynamically adapt their peak detection method to circumstances in which a decrease in the amplitude of the PPG signal is expected. Still, more extensive testing under a wide range of conditions (e.g. intensive physical exercise) is needed to perform a rigorous validation.Keywords
This publication has 11 references indexed in Scilit:
- Low Complexity Heart Rate Measurement from Wearable Wrist-Type Photoplethysmographic Sensors Robust to Motion Artifacts2018
- A Robust Peak Detection Algorithm for Photoplethysmographic Waveforms in Mobile DevicesJournal of Medical Imaging and Health Informatics, 2017
- A Robust Algorithm for Real-Time Peak Detection of Photoplethysmograms Using a Personal Computer MouseIEEE Sensors Journal, 2015
- Adaptive thresholding with inverted triangular area for real-time detection of the heart rate from photoplethysmogram traces on a smartphone2014
- Adaptive pulse segmentation and artifact detection in photoplethysmography for mobile applications2012
- On the Analysis of Fingertip Photoplethysmogram SignalsCurrent Cardiology Reviews, 2012
- Adaptive threshold method for the peak detection of photoplethysmographic waveformComputers in Biology and Medicine, 2009
- Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart RateAnesthesia & Analgesia, 2007
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- An Automatic Beat Detection Algorithm for Pressure SignalsIEEE Transactions on Biomedical Engineering, 2005