Rafael Daniel Serna Maldonado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rafael Daniel Serna Maldonado has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Erick Javier Argüello-Prada
Universidad Santiago de Cali
1 shared publication - Javier Ferney Castillo García
Faculty of Engineering and Basic Sciences, Universidad Autónoma de Occidente, Cali 760035, Colombia
1 shared publication - Jorge Iván López Perez
Departamento de Ingeniería Eléctrica y Computadoras, Instituto de Ciencias e Ingeniería de la Computación, Universidad Nacional del Sur, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Bahía Blanca, Argentina, Argentina
1 shared publication - Leonardo Antonio Bermeo Varón
Facultad de Ingeniería, Escuela de Ingeniería Eléctrica y Electrónica, Universidad del Valle, Cali 760032, Colombia
1 shared publication
Latest Publications
- 17 November 2018
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (8) , 569-577
A novel and low-complexity peak detection algorithm for heart rate estimation from low-amplitude photoplethysmographic (PPG) signals
Low-amplitude PPG signals are more affected by noise contamination and other undesirable effects because the signal strength is comparable to noise power. Although several authors claim that decreases in the amplitude of the PPG wave should be addressed from signal acquisition and conditioning stages such decreases can also be associated with changes in the patient condition. In that instance, it is important to ensure continuous and reliable HR monitoring which, in turn, depends on how robust is the peak detection method. Numerous efforts have been made to develop algorithms for accurate PPG peak detection under high motion artefact conditions. However, little has been done regarding peak detection in low-amplitude PPG signals. In an attempt to address this issue, a novel and simple peak detection algorithm for PPG signals was proposed. Results show that our method could be a good contribution for robust strategies that can dynamically adapt their peak detection method to circumstances in which a decrease in the amplitude of the PPG signal is expected. Still, more extensive testing under a wide range of conditions (e.g. intensive physical exercise) is needed to perform a rigorous validation.
- 17 November 2018
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (8) , 569-577
A novel and low-complexity peak detection algorithm for heart rate estimation from low-amplitude photoplethysmographic (PPG) signals
Low-amplitude PPG signals are more affected by noise contamination and other undesirable effects because the signal strength is comparable to noise power. Although several authors claim that decreases in the amplitude of the PPG wave should be addressed from signal acquisition and conditioning stages such decreases can also be associated with changes in the patient condition. In that instance, it is important to ensure continuous and reliable HR monitoring which, in turn, depends on how robust is the peak detection method. Numerous efforts have been made to develop algorithms for accurate PPG peak detection under high motion artefact conditions. However, little has been done regarding peak detection in low-amplitude PPG signals. In an attempt to address this issue, a novel and simple peak detection algorithm for PPG signals was proposed. Results show that our method could be a good contribution for robust strategies that can dynamically adapt their peak detection method to circumstances in which a decrease in the amplitude of the PPG signal is expected. Still, more extensive testing under a wide range of conditions (e.g. intensive physical exercise) is needed to perform a rigorous validation.