Turbine Blade Platform Film Cooling With Fan-Shaped Holes Under Simulated Swirl Purge Flow and Slashface Leakage Conditions
- 25 October 2017
- journal article
- research article
- Published by Wiley in Journal of Turbomachinery
- Vol. 140 (1) , 011006
Abstract
The combined effects of upstream purge flow, slashface leakage flow, and discrete hole film cooling on turbine blade platform film cooling effectiveness were studied using the pressure sensitive paint (PSP) technique. As a continued study, discrete cylindrical holes were replaced by laidback fan-shaped (10-10-5) holes, which generally provide better film coverages on the endwall. Experiments were done in a five-blade linear cascade. The inlet and exit Mach numbers were 0.26 and 0.43, respectively. The inlet and exit mainstream Reynolds numbers based on the axial chord length of the blade were 475,000 and 720,000, respectively. A wide range of parameters was evaluated in this study. The coolant-to-mainstream mass flow ratio (MFR) was varied from 0.5%, 0.75%, to 1% for the upstream purge flow. For the platform film cooling holes and slashface gap, average blowing ratios (M) of 0.5, 1.0, and 1.5 were examined. Coolant-to-mainstream density ratios (DR) that range from 1 (close to low-temperature experiments) to 1.5 (intermediate DR) and 2 (close to engine conditions) were also examined. Purge flow swirl effect was studied particularly at a typical swirl ratio (SR) of 0.6. Area-averaged film cooling effectiveness results were compared between cylindrical and fan-shaped holes. The results indicate that the fan-shaped holes provide superior film coverage than cylindrical holes for platform film cooling especially at higher blowing ratios and momentum flux ratios.Keywords
This publication has 49 references indexed in Scilit:
- Influence of Coolant Density on Turbine Blade Film-Cooling Using Pressure Sensitive Paint TechniqueJournal of Turbomachinery, 2011
- Film Cooling Effect of Rotor-Stator Purge Flow on Endwall Heat/Mass TransferJournal of Turbomachinery, 2011
- Effect of Density Ratio on Flat Plate Film Cooling With Shaped Holes Using PSPJournal of Turbomachinery, 2011
- Heat Transfer Measurements in a First-Stage Nozzle Cascade Having Endwall Contouring: Misalignment and Leakage StudiesJournal of Turbomachinery, 2006
- Gas Turbine Film CoolingJournal of Propulsion and Power, 2006
- Adiabatic Effectiveness Measurements of Endwall Film-Cooling for a First-Stage VaneJournal of Turbomachinery, 2005
- Adiabatic Effectiveness Measurements and Predictions of Leakage Flows Along a Blade EndwallJournal of Turbomachinery, 2005
- The Design of an Improved Endwall Film-Cooling ConfigurationJournal of Turbomachinery, 1999
- Flow Visualization in a Linear Turbine Cascade of High Performance Turbine BladesJournal of Turbomachinery, 1997
- Film Cooling of the Gas Turbine Endwall by Discrete-Hole InjectionJournal of Turbomachinery, 1996