Abstract
Awake fibreoptic intubation has always been considered the gold standard for expected difficult airway management. However, the use of fibreoptic intubation was limited because it is time-consuming, requires skillful operators and easily affected by blood or secretions in the oral or nasopharynx. We reported a modified technique of awake fibreoptic nasal intubation with the aid of End-tidal carbon dioxide (ETCO2) monitoring, aiming to improve the efficiency and safety of awake fibreoptic intubation.Keywords
This publication has 9 references indexed in Scilit:
- Difficult airway management practice changes after introduction of the GlideScope videolaryngoscopeEuropean Journal of Anaesthesiology, 2020
- Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adultsAnaesthesia, 2019
- Capnography-sample line leak and incremental positive end expiratory pressure (PEEP); an interesting interplayJournal of Clinical Monitoring and Computing, 2019
- Fibreoptic intubation in airway management: a review articleSingapore Medical Journal, 2019
- A Retrospective Study of Success, Failure, and Time Needed to Perform Awake IntubationAnesthesiology, 2016
- Fiberoptic Intubation: An Overview and UpdateRespiratory Care, 2014
- Nasal vs oral intubation.2003
- End-tidal carbon dioxide monitoring during awake blind nasotracheal intubationJournal of Clinical Anesthesia, 1990
- Blind Nasal Intubations by Monitoring End-Tidal co2Anesthesia & Analgesia, 1989