Carlos Hernando
Research Subjects
Carlos Hernando has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Maite Alvarez
Instituto Nacional de Tècnica Aeroespacial" (INTA), Torrejón de Ardoz, 28850 Madrid, Spain
11 shared publications - Héctor Guerrero
Instituto Nacional de Técnica Aeroespacial (INTA)
4 shared publications - Manuel Blanco-Velasco
Department of Teoría de la Señal y Comunicaciones, Universidad de Alcalá, Madrid, Spain
4 shared publications I. Arruego
3 shared publicationsJ. J. Jimenez
3 shared publicationsJose A. Dominguez
Instituto Nacional de Técnica Aeroespacial (INTA), 28850, Torrejón de Ardoz, Madrid, Spain
3 shared publications
Latest Publications
- Open Access
Time to First Fix Robustness of Global Navigation Satellite Systems: Comparison Study
The time to first fix (TTFF) measures the time elapsed by a global navigation satellite system (GNSS) receiver from switch-on to provision of a navigation solution. This parameter is crucial for applications where a position, within an acceptable error, is needed as soon as possible after turning the device on. The quality of the TTFF depends mainly on the receiver, the environment, and the GNSS satellites employed. Although all four available GNSSs (BeiDou, Galileo, GLONASS, and GPS) are complementary, their constellations and signals differ, providing different TTFF performances. This becomes even more relevant in hostile environments, where the TTFF degrades from nominal results. In this work, the robustness of the signals of the four GNSSs against different levels of harshness and its influence on the TTFF performance are evaluated in a comparative way. For this purpose, a typical scenario for mass-market GNSS applications, involving cold-start conditions, single-frequency signals, and a low-cost receiver, is considered. The results indicate that GPS provides the most robust TTFF, followed by GLONASS (although at the expense of positioning accuracy), BeiDou, and Galileo, in that order.
Open AccessTime to First Fix Robustness of Global Navigation Satellite Systems: Comparison Study
The time to first fix (TTFF) measures the time elapsed by a global navigation satellite system (GNSS) receiver from switch-on to provision of a navigation solution. This parameter is crucial for applications where a position, within an acceptable error, is needed as soon as possible after turning the device on. The quality of the TTFF depends mainly on the receiver, the environment, and the GNSS satellites employed. Although all four available GNSSs (BeiDou, Galileo, GLONASS, and GPS) are complementary, their constellations and signals differ, providing different TTFF performances. This becomes even more relevant in hostile environments, where the TTFF degrades from nominal results. In this work, the robustness of the signals of the four GNSSs against different levels of harshness and its influence on the TTFF performance are evaluated in a comparative way. For this purpose, a typical scenario for mass-market GNSS applications, involving cold-start conditions, single-frequency signals, and a low-cost receiver, is considered. The results indicate that GPS provides the most robust TTFF, followed by GLONASS (although at the expense of positioning accuracy), BeiDou, and Galileo, in that order.
- 15 November 2018
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 38 (6) , 2653-2676
Matching Pursuit Decomposition on Electrocardiograms for Joint Compression and QRS Detection
- 15 November 2018
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 38 (6) , 2653-2676
Matching Pursuit Decomposition on Electrocardiograms for Joint Compression and QRS Detection
- 6 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
On-Orbit measurements of TID and Dose Rate from two RADFETs on board NANOSAT-1B satellite
TID and Dose Rate data from 2 different RADFETs from Tyndall on board NANOSAT-1B from 2009 to the end of mission in July 2015 are presented. Data are in agreement with prediction models.
- 6 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
On-Orbit measurements of TID and Dose Rate from two RADFETs on board NANOSAT-1B satellite
TID and Dose Rate data from 2 different RADFETs from Tyndall on board NANOSAT-1B from 2009 to the end of mission in July 2015 are presented. Data are in agreement with prediction models.
- 11 August 2015
- Published by IOP Publishing in Physiological Measurement
- Vol. 36 (9) , 1981-1994
Consistent quality control in ECG compression by means of direct metrics
The aim of electrocardiogram (ECG) compression is to reduce the amount of data as much as possible while preserving the significant information for diagnosis. Objective metrics that are derived directly from the signal are suitable for controlling the quality of the compressed ECGs in practical applications. Many approaches have employed figures of merit based on the percentage root mean square difference (PRD) for this purpose. The benefits and drawbacks of the PRD measures, along with other metrics for quality assessment in ECG compression, are analysed in this work. We propose the use of the root mean square error (RMSE) for quality control because it provides a clearer and more stable idea about how much the retrieved ECG waveform, which is the reference signal for establishing diagnosis, separates from the original. For this reason, the RMSE is applied here as the target metric in a thresholding algorithm that relies on the retained energy. A state of the art compressor based on this approach, and its PRD-based counterpart, are implemented to test the actual capabilities of the proposed technique. Both compression schemes are employed in several experiments with the whole MIT–BIH Arrhythmia Database to assess both global and local signal distortion. The results show that, using the RMSE for quality control, the distortion of the reconstructed signal is better controlled without reducing the compression ratio.
- 11 August 2015
- Published by IOP Publishing in Physiological Measurement
- Vol. 36 (9) , 1981-1994
Consistent quality control in ECG compression by means of direct metrics
The aim of electrocardiogram (ECG) compression is to reduce the amount of data as much as possible while preserving the significant information for diagnosis. Objective metrics that are derived directly from the signal are suitable for controlling the quality of the compressed ECGs in practical applications. Many approaches have employed figures of merit based on the percentage root mean square difference (PRD) for this purpose. The benefits and drawbacks of the PRD measures, along with other metrics for quality assessment in ECG compression, are analysed in this work. We propose the use of the root mean square error (RMSE) for quality control because it provides a clearer and more stable idea about how much the retrieved ECG waveform, which is the reference signal for establishing diagnosis, separates from the original. For this reason, the RMSE is applied here as the target metric in a thresholding algorithm that relies on the retained energy. A state of the art compressor based on this approach, and its PRD-based counterpart, are implemented to test the actual capabilities of the proposed technique. Both compression schemes are employed in several experiments with the whole MIT–BIH Arrhythmia Database to assess both global and local signal distortion. The results show that, using the RMSE for quality control, the distortion of the reconstructed signal is better controlled without reducing the compression ratio.
- Open Access
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21540519,p. 1-4
Effects of gamma-Ray Radiation on Magnetic Properties of NdFeB and SmCo Permanent Magnets for Space Applications
Several samples of NdFeB and SmCo permanent magnets have been irradiated with gamma rays up to different total irradiation doses until 1Mrad(Si). Magnetic properties of the samples have been measured at different temperatures before and after irradiation. The modifications of the magnetic parameters are presented. From these results it is highlighted which permanent magnets show more resistance to radiation and are more suitable to be included in devices for space applications or high radiation environments.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21540519,p. 1-4
Open AccessEffects of gamma-Ray Radiation on Magnetic Properties of NdFeB and SmCo Permanent Magnets for Space Applications
Several samples of NdFeB and SmCo permanent magnets have been irradiated with gamma rays up to different total irradiation doses until 1Mrad(Si). Magnetic properties of the samples have been measured at different temperatures before and after irradiation. The modifications of the magnetic parameters are presented. From these results it is highlighted which permanent magnets show more resistance to radiation and are more suitable to be included in devices for space applications or high radiation environments.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21540519,p. 1-3
TID Test Results of Optical Materials and Photodiodes for SIS Instrument (Dreams Project)
The sensitivity to total dose of optical materials and custom photodiodes candidates for EXOMARS 2016 is studied. Tested materials include: Teflon®, Delrin® and five different optical filter glasses from Schottt and Optics Balzers Jena.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21540519,p. 1-3
TID Test Results of Optical Materials and Photodiodes for SIS Instrument (Dreams Project)
The sensitivity to total dose of optical materials and custom photodiodes candidates for EXOMARS 2016 is studied. Tested materials include: Teflon®, Delrin® and five different optical filter glasses from Schottt and Optics Balzers Jena.
- 2 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (6) , 4281-4288
Total Ionizing Dose Characterization of a Prototype Floating Gate MOSFET Dosimeter for Space Applications
A new dosimeter for total ionizing dose that is based on a floating gate MOSFET is presented. The chip incorporates a reference standard MOSFET for temperature compensation and front-end electronics to provide manageable output signals. The floating gate is automatically recharged through an included charge pump circuitry, thus its operating range is spread without affecting the sensitivity. Two different sensitivity configurations are included in the same chip, so the dosimeter can be used under different radiation environments. An initial characterization has been carried out in order to evaluate its suitability for space missions. The results show that the proposed floating gate radiation dosimeter is adequate for space missions with levels of total ionizing dose up to at least 10 krad(Si).
- 2 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (6) , 4281-4288
Total Ionizing Dose Characterization of a Prototype Floating Gate MOSFET Dosimeter for Space Applications
A new dosimeter for total ionizing dose that is based on a floating gate MOSFET is presented. The chip incorporates a reference standard MOSFET for temperature compensation and front-end electronics to provide manageable output signals. The floating gate is automatically recharged through an included charge pump circuitry, thus its operating range is spread without affecting the sensitivity. Two different sensitivity configurations are included in the same chip, so the dosimeter can be used under different radiation environments. An initial characterization has been carried out in order to evaluate its suitability for space missions. The results show that the proposed floating gate radiation dosimeter is adequate for space missions with levels of total ionizing dose up to at least 10 krad(Si).
- 14 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (4) , 2461-2468
Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor
A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite.
- 14 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (4) , 2461-2468
Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor
A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Total Ionizing Dose Radiation Test on the Temperature Sensor TMP36 from Analog Devices
TMP36 temperature sensors were irradiated with Co-60 gamma rays up to 35 krad(Si). This temperature sensor will be used as a total ionizing dose sensor in a radiation monitor that will be on board the Spanish Earth observation satellite SEOSAT/INGENIO. Several samples were irradiated at different dose rates while their response was continuously measured. The sensitivity of the TMP36 to the total ionizing dose has been assessed by studying the evolution of the next three metrics: the output voltage, its temperature dependence and the power consumption. It has been observed that the degradation of these parameters increase significantly at doses higher than about 7 krad(Si), independently of the dose rate.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Total Ionizing Dose Radiation Test on the Temperature Sensor TMP36 from Analog Devices
TMP36 temperature sensors were irradiated with Co-60 gamma rays up to 35 krad(Si). This temperature sensor will be used as a total ionizing dose sensor in a radiation monitor that will be on board the Spanish Earth observation satellite SEOSAT/INGENIO. Several samples were irradiated at different dose rates while their response was continuously measured. The sensitivity of the TMP36 to the total ionizing dose has been assessed by studying the evolution of the next three metrics: the output voltage, its temperature dependence and the power consumption. It has been observed that the degradation of these parameters increase significantly at doses higher than about 7 krad(Si), independently of the dose rate.