Analysis of Failure in Miniature X‐ray Tubes with Gated Carbon Nanotube Field Emitters
Open Access
- 4 December 2013
- journal article
- letter
- Published by Wiley in ETRI Journal
- Vol. 35 (6) , 1164-1167
Abstract
We correlate the failure in miniature X‐ray tubes with the field emission gate leakage current of gated carbon nanotube emitters. The miniature X‐ray tube, even with a small gate leakage current, exhibits an induced voltage on the gate electrode by the anode bias voltage, resulting in a very unstable operation and finally a failure. The induced gate voltage is apparently caused by charging at the insulating spacer of the miniature X‐ray tube through the gate leakage current of the field emission. The gate leakage current could be a criterion for the successful fabrication of miniature X‐ray tubes.Keywords
Funding Information
- Ministry of Science, ICT and Future Planning
- Ministry of Trade, Industry and Energy (10035553)
This publication has 10 references indexed in Scilit:
- A vacuum-sealed compact x-ray tube based on focused carbon nanotube field-emission electronsNanotechnology, 2013
- A digital miniature x-ray tube with a high-density triode carbon nanotube field emitterApplied Physics Letters, 2013
- Secondary electron emission in a triode carbon nanotube field emission display and its influence on the image qualityCarbon, 2012
- A vacuum-sealed miniature X-ray tube based on carbon nanotube field emittersDiscover Nano, 2012
- Miniature X‐Ray Tubes2010
- CNT‐Based FEL for BLU in LCD2010
- The high contrast ratio and fast response time of a liquid crystal display lit by a carbon nanotube field emission backlight unitNanotechnology, 2008
- A miniature x-ray tubeApplied Physics Letters, 2004
- Active-Matrix Field Emission Display with Amorphous Silicon Thin-Film Transistors and Mo-Tip Field Emitter ArraysETRI Journal, 2002