Predicting Device‐Induced Platelet Damage in Assisted Circulation Using a New Biophysical Model and Experimental Validation
Open Access
- 4 September 2026
- journal article
- main text
- Published by Wiley in Artificial Organs
Abstract
Background: Platelet activation and receptor shedding caused by non‐physiological shear stress remain a critical challenge in the design and clinical performance of circulatory assist devices. Computational fluid dynamics (CFD)‐based approaches have been widely used by coupling flow‐derived scalar shear stress with empirical damage models to predict platelet activation. In this study, we evaluate the effectiveness of our recently proposed biophysical damage model for predicting platelet activation and receptor shedding caused by circulatory assist devices. Methods: Four rotary blood pumps have been chosen for this study: One axial pump (HeartMate II) and three centrifugal pumps (HeartMate 3, BrioVAD, and CentriMag). CFD simulations were performed under three clinically relevant circulatory support conditions: HeartMate II, HeartMate 3, BrioVAD at a pressure head of 75 mmHg, along with CentriMag at pressure heads of 75, 150, and 350 mmHg. The resulting platelet damage indices were compared with experimentally measured platelet activation (PAC‐1 expression) and receptor shedding (GPIbα and GPVI) data. Results: HeartMate 3, BrioVAD, and CentriMag operating at 75 mmHg caused the lowest levels of platelet activation and receptor shedding, while CentriMag, operating at 350 mmHg, produced the highest, 10 times more activation, and six times more receptor shedding compared to at 75 mmHg. Strong correlations were observed between CFD predicted and in vitro data for all biomarkers (), with the highest agreement observed for GPVI shedding (). Conclusion: The biophysical model preserved the relative trends observed previously with the power‐law formulation, while demonstrating improved agreement with experimental data.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL162940)
- National Heart, Lung, and Blood Institute (R01HL171120)
This publication has 29 references indexed in Scilit:
- From Early Models to Emerging Trends: The Evolution of Computational Hemolysis PredictionAnnals of Biomedical Engineering, 2026
- Design and rationale for the clinical investigation of a novel, magnetically levitated left ventricular assist device for the treatment of refractory heart failureThe Journal of Heart and Lung Transplantation, 2025
- Hemocompatibility and hemodynamic comparison of two centrifugal LVADs: HVAD and HeartMate3Biomechanics and Modeling in Mechanobiology, 2023
- Examining the universality of the hemolysis power law model from simulations of the FDA nozzle using calibrated model coefficientsBiomechanics and Modeling in Mechanobiology, 2022
- Multi-indicator analysis of mechanical blood damage with five clinical ventricular assist devicesComputers in Biology and Medicine, 2022
- Discrete responses of erythrocytes, platelets, and von Willebrand factor to shearJournal of Biomechanics, 2022
- In Vitro Benchmarking Study of Ventricular Assist Devices in Current Clinical UseJournal of Cardiac Failure, 2020
- The Society of Thoracic Surgeons Intermacs database annual report: Evolving indications, outcomes, and scientific partnershipsThe Journal of Heart and Lung Transplantation, 2019
- Development of a computational model for macroscopic predictions of device-induced thrombosisBiomechanics and Modeling in Mechanobiology, 2016
- Activation and shedding of platelet glycoprotein IIb/IIIa under non-physiological shear stressMolecular and Cellular Biochemistry, 2015