Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography
Authors:
- 29 August 2012
- journal article
- research article
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 97 (5) , F340-F343
Abstract
Objective: Electrical velocimetry (EV) is a non-invasive method of continuous left cardiac output monitoring based on measurement of thoracic electrical bioimpedance. The objective was to validate EV by investigating the agreement in cardiac output measurements performed by EV and echocardiography. Design: In this prospective observational study, left ventricular output (LVO) was simultaneously measured by EV (LVOev) using Aesculon and by echocardiography (LVOecho) in healthy term neonates during the first 2 postnatal days. To determine the agreement between the two methods, we calculated the bias (mean difference) and precision (1.96×SD of the difference). As LVOecho has its own limitations, the authors also calculated the ‘true precision’ of EV adjusted for echocardiography as the reference method. Results: The authors performed 115 paired measurements in 20 neonates. LVOev and LVOecho were similar (534±105 vs 538±105 ml/min, p=0.7). The bias and precision of EV were −4 and 234 ml/min, respectively. The authors found the true precision of EV to be similar to the precision of echocardiography (31.6% vs 30%, respectively). There was no difference in bias and precision between the measurements obtained in patients with or without a haemodynamically significant patent ductus arteriosus. Conclusions: EV is as accurate in measuring LVO as echocardiography and the variation in the agreement between EV and echocardiography among the individual subjects reflects the limitations of both techniques.Keywords
This publication has 14 references indexed in Scilit:
- Patent ductus arteriosus in the preterm infant: to treat or not to treat?Journal of Perinatology, 2010
- Cardiac output monitoring in newbornsEarly Human Development, 2010
- Clinical monitoring of systemic hemodynamics in critically ill newbornsEarly Human Development, 2010
- Electrical velocimetry for measuring cardiac output in children with congenital heart diseaseBritish Journal of Anaesthesia, 2007
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- RETRACTED ARTICLE: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilutionIntensive Care Medicine, 2006
- Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literatureIntensive Care Medicine, 2003
- A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement TechniquesJournal of Clinical Monitoring and Computing, 1999
- Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilationThe Journal of Pediatrics, 1995
- Noninvasive pulsed Doppler determination of cardiac output in neonates and childrenThe Journal of Pediatrics, 1982