Electrical velocimetry for measuring cardiac output in children with congenital heart disease
Authors:
Open Access
- 16 November 2007
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 100 (1) , 88-94
Abstract
The purpose of this study was to evaluate the agreement of cardiac output measurements obtained by electrical velocimetry (COEV) and those that derived from the direct Fick-oxygen principle (COF) in infants and children with congenital heart defects. Simultaneous measurements of COEV and COF were compared in 32 paediatric patients, aged 11 days to 17.8 yr, undergoing diagnostic right and left heart catheterization. For non-invasive measurements of cardiac output by electrical velocimetry, which is a variation of impedance cardiography, standard surface electrodes were applied to the left side of the neck and the left side of the thorax at the level of the xiphoid process. Cardiac output determined using direct Fick-oxygen principle was calculated by direct measurement of oxygen consumption (VO2) and invasive determination of the arterio-venous oxygen content difference. An excellent correlation (r=0.97) was found between COEV and COF (PEV–COF) was 0.01 litre min−1 and the limits of agreement, defined as the bias (2 sd), were −0.47 and +0.45 litre min−1. COEV demonstrates acceptable agreement with data derived from COF in infants and children with congenital heart disease. The new technique is simple, completely non-invasive, and provides beat-to-beat estimation of CO.Keywords
This publication has 23 references indexed in Scilit:
- Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in pigletsPediatric Anesthesia, 2007
- Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Bench to Bedside: Electrophysiologic and Clinical Principles of Noninvasive Hemodynamic Monitoring Using Impedance CardiographyAcademic Emergency Medicine, 2003
- Why measure cardiac output?Critical Care, 2003
- Lack of Agreement Between Thermodilution and Fick Cardiac Output in Critically Ill PatientsChest, 2002
- Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patientsCritical Care, 2002
- Determination of Cardiac Output by the Fick Method, Thermodilution, and Acetylene Rebreathing in Pulmonary HypertensionAmerican Journal of Respiratory and Critical Care Medicine, 1999
- Errors in the measurement of cardiac output by thermodilutionCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants.Heart, 1992
- A new stroke volume equation for thoracic electrical bioimpedanceCritical Care Medicine, 1986