Effect of Bioimpedance Body Composition Analysis on Function of Implanted Cardiac Devices
Authors:
- 27 March 2012
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (6) , 681-684
Abstract
Background: It is routinely recommended that patients with pacemakers, implantable cardioverter defibrillators (ICD), and cardiac resynchronization therapy‐defibrillators (CRT‐D) avoid bioelectrical impedance analysis (BIA)—a commonly used method to estimate body composition—because of the concern for the potential for BIA interference with pacemaker or ICD function. However, the prevalence of such interference is not known. Objective: Assess for incidence of interference between BIA and ICD or CRT‐D devices. Methods and Results: Twenty patients with heart failure and cardiac implanted electronic devices (50% ICD, 50% CRT‐D) underwent BIA during real‐time device interrogation to detect interference. Study patients were 90% male, with mean age 54 ±14 years, and mean LVEF 23 ± 11%. Devices from all four leading cardiac device manufacturers were included. Device therapies were temporarily disabled to prevent inappropriate shocks. During body composition testing using BIA, no evidence of interference with ICD function was seen in any patient, including no telemetry disruption, no oversensing on any lead, and no patient symptoms. Conclusions: Despite the manufacturers’ recommendation to avoid BIA in patients with ICDs, this study showed no evidence of any interference in 20 patients. Bioimpedance analysis might be safe in such patients, but further confirmatory studies are required. (PACE 2012; 35:681–684)Keywords
This publication has 16 references indexed in Scilit:
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Association Between Direct Measures of Body Composition and Prognostic Factors in Chronic Heart FailureMayo Clinic Proceedings, 2010
- In vitro tests reveal sample radiofrequency identification readers inducing clinically significant electromagnetic interference to implantable pacemakers and implantable cardioverter-defibrillatorsHeart Rhythm, 2010
- Body composition determination by bioimpedance: an updateCurrent Opinion in Clinical Nutrition and Metabolic Care, 2009
- Left Ventricular Mechanical Assist Devices and Cardiac Device Interactions: An Observational Case SeriesPacing and Clinical Electrophysiology, 2009
- Risk of Interference from Transcutaneous Electrical Nerve Stimulation on the Sensing Function of Implantable DefibrillatorsPacing and Clinical Electrophysiology, 2008
- Bioelectrical impedance and strength measurements in patients with heart failure: comparison with functional classNutrition, 2007
- Electromagnetic Interference from Wireless Video-Capsule Endoscopy on Implantable Cardioverter-DefibrillatorsPacing and Clinical Electrophysiology, 2007
- Bioelectrical impedance analysis—part II: utilization in clinical practiceClinical Nutrition, 2004
- Wasting as independent risk factor for mortality in chronic heart failureThe Lancet, 1997