Chloride Diffusion in Concrete Protected with a Silane-Based Corrosion Inhibitor
Open Access
Abstract
One of the most important parameters concerning durability is undoubtedly represented by cement matrix resistance to chloride diffusion in environments where reinforced concrete structures are exposed to the corrosion risk induced by marine environment or de-icing salts. This paper deals with protection from chloride ingress by a silane-based surface-applied corrosion inhibitor. Results indicated that the corrosion inhibitor (CI) allows to reduce the penetration of chloride significantly compared to untreated specimens, independently of w/c, cement type, and dosage. Reduction of chloride diffusion coefficient (Dnssn) measured by an accelerated test in treated concrete was in the range 30–60%. Natural chloride diffusion test values indicate a sharp decrease in apparent diffusion coefficient (Dapp) equal to about 75% when concrete is protected by CI. Mechanism of action of CI in slowing down the chloride penetration inside the cement matrix is basically due to the water repellent effect as confirmed by data of concrete bulk electrical resistivity.Keywords
This publication has 43 references indexed in Scilit:
- Time dependent models of apparent diffusion coefficient and surface chloride for chloride transport in fly ash concreteConstruction and Building Materials, 2013
- Practical evaluation of relationship between concrete resistivity, water penetration, rapid chloride penetration and compressive strengthConstruction and Building Materials, 2011
- Effect of cement type on the resistance of concrete against chloride penetrationConstruction and Building Materials, 2011
- Effectiveness of amino alcohol-based surface-applied corrosion inhibitors in chloride-contaminated concreteCement and Concrete Research, 2007
- AgNO3 spray tests: advantages, weaknesses, and various applications to quantify chloride ingress into concrete. Part 2: Non-steady-state migration tests and chloride diffusion coefficientsMaterials and Structures, 2007
- Theoretical considerations on the supposed linear relationship between concrete resistivity and corrosion rate of steel reinforcementMaterials and Corrosion, 2005
- The use of migrating corrosion inhibitors to repair motorways' concrete structures contaminated by chloridesCement and Concrete Research, 2005
- Concentration monitoring and performance of a migratory corrosion inhibitor in steel-reinforced concreteCement and Concrete Research, 2004
- A migrating corrosion inhibitor evaluated in concrete containing various contents of admixed chloridesCement and Concrete Research, 2002
- Penetration of Chloride Ions into Cement Pastes and ConcretesJournal of the American Ceramic Society, 1972