A statistical approach to explore cemented total hip reconstruction performance
- 19 February 2018
- journal article
- research article
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 41 (1) , 177-188
Abstract
This study was carried out to determine mechanical behavior and bone adaptation of total hip arthroplasty (THA) subject to concentrated and distributed muscle loads and hip contact forces during activities of walking and stair climbing. Finite element modeling of THA with different prostheses, activity and loading types was developed by adopting a statistical method. Two levels of prostheses, activity, and loading types were selected for the study. 23 factorial method was then pursued to design input and output data of finite element analysis. Maximum von Mises stresses were chosen to be output data on which statistical investigation was performed to investigate contribution and interaction of main factors on mechanical failure of cemented THA reconstructions by utilizing analysis of variance method (ANOVA). This study illustrated that the maximum von Mises stresses of THA showed considerable variation for main factors and their two-factor interactions.Keywords
This publication has 29 references indexed in Scilit:
- The Investigation Of A 3-Dimensional Human Hip Joint Subjected To Distributed Load By Using Finite Element MethodSakarya University Journal of Science, 2012
- Design process of a novel cemented hip femoral stem conceptMaterials & Design (1980-2015), 2012
- The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic FemursJournal of Biomechanical Engineering, 2006
- Determination of muscle loading at the hip joint for use in pre-clinical testingJournal of Biomechanics, 2005
- Aseptic looseningGene Therapy, 2004
- Process of hip joint prosthesis design including bone remodeling phenomenonComputers & Structures, 2003
- Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 casesActa Orthopaedica, 2000
- The ‘standardized femur program’ proposal for a reference geometry to be used for the creation of finite element models of the femurJournal of Biomechanics, 1996
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- ARTHROPLASTY OF THE HIP A New OperationThe Lancet, 1961