Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T
Authors:
Open Access
- 20 August 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (1) , 291-300
Abstract
Purpose To design and validate a radiofrequency (RF) array coil for cervical spinal cord imaging at 7T. Methods A 19‐channel receive array with a four‐channel transmit array was developed on a close‐fitting coil former at 7T. Transmit efficiency and specific absorption rate were evaluated in a B1+ mapping study and an electromagnetic model. Receive signal‐to‐noise ratio (SNR) and noise amplification for parallel imaging were evaluated and compared with a commercial 3T 19‐channel head–neck array and a 7T four‐channel spine array. The performance of the array was qualitatively demonstrated in human volunteers using high‐resolution imaging (down to 300 μm in‐plane). Results The transmit and receive arrays showed good bench performance. The SNR was approximately 4.2‐fold higher in the 7T receive array at the location of the cord with respect to the 3T coil. The g‐factor results showed an additional acceleration was possible with the 7T array. In vivo imaging was feasible and showed high SNR and tissue contrast. Conclusion The highly parallel transmit and receive arrays were demonstrated to be fit for spinal cord imaging at 7T. The high sensitivity of the receive coil combined with ultra‐high field will likely improve investigations of microstructure and tissue segmentation in the healthy and pathological spinal cord. Magn Reson Med 72:291–300, 2014.Keywords
Funding Information
- National Institutes of Health (P41EB015896, K24NS59892)
- National Multiple Sclerosis Society (FG1892A1/1)
This publication has 28 references indexed in Scilit:
- 32‐Channel RF coil optimized for brain and cervical spinal cord at 3 TMagnetic Resonance in Medicine, 2011
- A radiofrequency coil configuration for imaging the human vertebral column at 7TJournal of Magnetic Resonance, 2011
- A 32‐channel lattice transmission line array for parallel transmit and receive MRI at 7 teslaMagnetic Resonance in Medicine, 2010
- An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 TInvestigative Radiology, 2009
- Slice‐selective RF pulses for in vivo B inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16‐element coilMagnetic Resonance in Medicine, 2008
- Spinal cord grey matter lesions in multiple sclerosis detected by post-mortem high field MR imagingMultiple Sclerosis Journal, 2008
- Reciprocity and gyrotropism in magnetic resonance transductionPhysical Review A, 2006
- Eight‐channel phased array coil and detunable TEM volume coil for 7 T brain imagingMagnetic Resonance in Medicine, 2005
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999