Mechanical Characterization of a Viscoelastic Disc for Lumbar Total Disc Replacement
- 1 March 2011
- journal article
- Published by ASME International in Journal of Medical Devices
- Vol. 5 (1) , 011005
Abstract
A viscoelastic artificial disc may more closely replicate normal stiffness characteristics of the healthy human disc compared with first-generation total disc replacement (TDR) devices, which do not utilize viscoelastic materials and are based on a ball and socket design that does not allow loading compliance. Mechanical testing was performed to characterize the durability and range of motion (ROM) of an investigational viscoelastic TDR (VTDR) device for the lumbar spine, the Freedom® Lumbar Disc. ROM data were compared with data reported for the human lumbar disc in the clinical literature. Flexibility and stiffness of the VTDR in compression, rotation, and flexion/extension were within the parameters associated with the normal human lumbar disc. The device constrained motion to physiologic ranges and replicated normal stress/strain dynamics. No mechanical or functional failures occurred within the loads and ROM experienced by the human disc. Fatigue testing of the worst case VTDR device size demonstrated a fatigue life of 50 years of simulated walking and 240 years of simulated significant bends in both flexion/extension and lateral bending coupled with axial rotation, with no functional failures. These results indicate that the VTDR evaluated in this mechanical study is durable and has the ability to replicate the stiffness and mechanics of the natural, healthy human lumbar disc.Keywords
This publication has 47 references indexed in Scilit:
- Lumbar Adjacent Segment Degeneration and Disease After Arthrodesis and Total Disc ArthroplastySpine, 2008
- Lumbar Total Disc Replacement Using ProDisc IIJournal of Spinal Disorders & Techniques, 2006
- Range of motion and adjacent level degeneration after lumbar total disc replacementThe Spine Journal, 2006
- Charité total disc replacement—clinical and radiographical results after an average follow-up of 17 yearsEuropean Spine Journal, 2005
- Iliac Crest Bone Graft Donor Site Pain After Anterior Lumbar Interbody FusionJournal of Spinal Disorders & Techniques, 2005
- Critical Analysis of Trends in Fusion for Degenerative Disc Disease Over the Past 20 YearsSpine, 2004
- Long-Term Flexion-Extension Range of Motion of the Prodisc Total Disc ReplacementJournal of Spinal Disorders & Techniques, 2003
- Pedicle screw fixation in spinal disorders: A European viewEuropean Spine Journal, 1997
- Adjacent-Segment Degeneration After Lumbar Fusion with InstrumentationJournal of Spinal Disorders, 1996
- Patient outcomes after lumbar spinal fusionsJAMA, 1992