EREdward R.S. Ross

Edward R.S. Ross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Edward R.S. Ross has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mechanical Characterization of a Viscoelastic Disc for Lumbar Total Disc Replacement

    by Edward C. Benzel, Isador H. Lieberman, E. Raymond Ross, Raymond J. Linovitz, James Kuras, Kari Zimmers

    A viscoelastic artificial disc may more closely replicate normal stiffness characteristics of the healthy human disc compared with first-generation total disc replacement (TDR) devices, which do not utilize viscoelastic materials and are based on a ball and socket design that does not allow loading compliance. Mechanical testing was performed to characterize the durability and range of motion (ROM) of an investigational viscoelastic TDR (VTDR) device for the lumbar spine, the Freedom® Lumbar Disc. ROM data were compared with data reported for the human lumbar disc in the clinical literature. Flexibility and stiffness of the VTDR in compression, rotation, and flexion/extension were within the parameters associated with the normal human lumbar disc. The device constrained motion to physiologic ranges and replicated normal stress/strain dynamics. No mechanical or functional failures occurred within the loads and ROM experienced by the human disc. Fatigue testing of the worst case VTDR device size demonstrated a fatigue life of 50 years of simulated walking and 240 years of simulated significant bends in both flexion/extension and lateral bending coupled with axial rotation, with no functional failures. These results indicate that the VTDR evaluated in this mechanical study is durable and has the ability to replicate the stiffness and mechanics of the natural, healthy human lumbar disc.


  • Survival and clinical outcome of SB Charité III disc replacement for back pain

    by R. Ross, A. H. Mirza, H. E. Norris, M. Khatri

    Between January 1990 and December 2000 we carried out 226 SB Charité III disc replacements for lumbar disc degeneration in 160 patients. They were reviewed at a mean follow-up of 79 months (31 to 161) to determine the clinical and radiological outcome. The clinical results were collected by an independent observer, who was not involved in patient selection, treatment or follow-up, using a combination of outcome measures, including the Oswestry Disability Index. Pain was recorded using a visual analogue score, and the most recent radiographs were reviewed. Survival of the device was analysed by the Kaplan-Meier method and showed a cumulative survival of 35% at 156 months when radiological failure was taken as the endpoint. The mean improvement in the Oswestry disability index scores after disc replacement was 14% (6% to 21%) and the mean improvement in the pain score was 1.6 (0.46 to 2.73), both falling below the clinically significant threshold. Removal of the implant was required in 12 patients, four because of implant failure. These poor results indicate that further use of this implant is not justified.