Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator
Authors:
- G H BolGBG H Bol
- S HissoinySHS Hissoiny
- J J W LagendijkJLJ J W Lagendijk
- B W RaaymakersBRB W Raaymakers
- 21 February 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (5) , 1375-1385
Abstract
The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In this paper, a fast IMRT optimization system is described which combines a GPU-based Monte Carlo dose calculation engine for online beamlet generation and a fast inverse dose optimization algorithm. Tightly conformal IMRT plans are generated for four phantom cases and two clinical cases (cervix and kidney) in the presence of the magnetic fields of 0 and 1.5 T. We show that for the presented cases the beamlet generation and optimization routines are fast enough for online IMRT planning. Furthermore, there is no influence of the magnetic field on plan quality and complexity, and equal optimization constraints at 0 and 1.5 T lead to almost identical dose distributions.Keywords
This publication has 20 references indexed in Scilit:
- Fast dose calculation in magnetic fields withGPUMCDPhysics in Medicine & Biology, 2011
- Shading correction for on‐board cone‐beam CT in radiation therapy using planning MDCT imagesMedical Physics, 2010
- Monte Carlo characterization of skin doses in 6 MV transverse field MRI‐linac systems: Effect of field size, surface orientation, magnetic field strength, and exit bolusMedical Physics, 2010
- Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific CalibrationMedical Dosimetry, 2010
- Magnetic field effects on the energy deposition spectra of MV photon radiationPhysics in Medicine & Biology, 2008
- Dose optimization for the MRI-accelerator: IMRT in the presence of a magnetic fieldPhysics in Medicine & Biology, 2007
- Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculationsMedical Physics, 2007
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic fieldPhysics in Medicine & Biology, 2007
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electronsPhysics in Medicine & Biology, 2005
- 224 Invited MRI guided radiotherapy: MRI as position verifcation system for IMRTRadiotherapy and Oncology, 2002