Christian Lettieri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christian Lettieri has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Massimo Mondani
Neurosurgery Unit, S. Maria della Misericordia University Hospital, Udine, Italy
2 shared publications- Stanislao D'AUria
Neurosurgery Unit, Head-Neck and Neurosciences Department, Azienda Ospedaliero Universitaria Friuli Centrale, 33100 Udine, Italy
2 shared publications Antonella Piani
S.O.C. Neurologia, Azienda Ospedaliero Universitaria "Santa Maria della Misericordia", Udine, Italy
1 shared publicationEnrico Belgrado
S.O.C. Neurologia, Azienda Ospedaliero Universitaria "Santa Maria della Misericordia", Udine, Italy
1 shared publication- Grazia Devigili
Department of Clinical Neurosciences, Parkinson and Movement Disorders Unit Fondazione IRCCS Istituto Neurologico Carlo Besta Milan Italy
1 shared publication - Luca De Simone
Area of Neuroscience, SISSA, Trieste, Italy
1 shared publication
Latest Publications
- 1 January 2019
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 97 (5-6) , 337-346
Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients
Background: Proper lead placement is considered one of the key factors in achieving a good clinical outcome in deep brain stimulation (DBS), but there is still considerable controversy surrounding the accuracy of the frameless in comparison to the frame-based technique. Objective: We report our single-center experience with DBS electrode placement to evaluate the accuracy of the frameless stereotactic system. Methods: We prospectively analyzed the data of 110 patients who underwent DBS surgery for Parkinson disease, dystonia, essential tremor, or refractory epilepsy. The final targets (FTs) of the 220 leads were: subthalamic nucleus, globus pallidus pars interna, ventralis intermedius nucleus, and anterior nuclei of thalamus in thalamus. A bilateral stereotactic approach using a combined identification of target based on preoperative images (MRI and CT scan fusion) and intra-operative micro-electrode recording (MER) were done. We collected and compared the coordinates of planned target (PT), the definitive expected target (ET) during MER, and the effective final location (FT) of the lead using the postoperative CT. Accuracy was assessed by both vector error (VE) and deviation from the PT. Results: The mean and SD from PTs was 0.78 ± 0.43 mm in the x direction, 0.68 ± 0.41 mm in the y direction, and 0.76 ± 0.41 mm in the z direction. Global VE was 1.43 ± 0.37. Conclusion: Frameless systems appear to be a reliable and accurate technique.
- 1 January 2019
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 97 (5-6) , 337-346
Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients
Background: Proper lead placement is considered one of the key factors in achieving a good clinical outcome in deep brain stimulation (DBS), but there is still considerable controversy surrounding the accuracy of the frameless in comparison to the frame-based technique. Objective: We report our single-center experience with DBS electrode placement to evaluate the accuracy of the frameless stereotactic system. Methods: We prospectively analyzed the data of 110 patients who underwent DBS surgery for Parkinson disease, dystonia, essential tremor, or refractory epilepsy. The final targets (FTs) of the 220 leads were: subthalamic nucleus, globus pallidus pars interna, ventralis intermedius nucleus, and anterior nuclei of thalamus in thalamus. A bilateral stereotactic approach using a combined identification of target based on preoperative images (MRI and CT scan fusion) and intra-operative micro-electrode recording (MER) were done. We collected and compared the coordinates of planned target (PT), the definitive expected target (ET) during MER, and the effective final location (FT) of the lead using the postoperative CT. Accuracy was assessed by both vector error (VE) and deviation from the PT. Results: The mean and SD from PTs was 0.78 ± 0.43 mm in the x direction, 0.68 ± 0.41 mm in the y direction, and 0.76 ± 0.41 mm in the z direction. Global VE was 1.43 ± 0.37. Conclusion: Frameless systems appear to be a reliable and accurate technique.