Design, Additive Manufacture, and Control of a Pneumatic MR-Compatible Needle Driver
- 19 January 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 32 (1) , 138-149
Abstract
This paper reports the design, modeling, and control of an MR-compatible actuation unit comprising pneumatic stepper mechanisms. One helix-shaped bellows and one toroid-shaped bellows were designed to actuate in pure rotation and pure translation, respectively. The actuation unit is a 2-degree-of-freedom (DOF) needle driver that translates and rotates the base of one tube of a steerable needle like a concentric tube robot. For safety, mechanical stops limit needle motion to maximum unplanned step sizes of 0.5 mm and 0.5°. Additively manufactured by selective laser sintering, the flexible fluidic actuating (FFA) mechanism achieves 2-DOF motion as a monolithic, compact, and hermetically sealed device. A second novel contribution is substep control for precise translations and rotations less than full-step increments; steady-state errors of 0.013 mm and 0.018° were achieved. The linear FFA produced peak forces of 33 and -26.5 N for needle insertion and retraction, respectively. The rotary FFA produced bidirectional peak torques of 68 N·mm. With the FFAs in full motion in a 3-T scanner, no loss in signal-to-noise ratio of MR images observed.Keywords
Funding Information
- National Science Foundation Engineering Research Center for Compact and Efficient Fluid Power (EEC-0540834)
This publication has 39 references indexed in Scilit:
- Design and Experimental Assessment of an Elastically Averaged Binary Manipulator Using Pneumatic Air Muscles for Magnetic Resonance Imaging Guided Prostate InterventionsJournal of Mechanical Design, 2011
- The Bionic Handling Assistant: a success story of additive manufacturingAssembly Automation, 2011
- MRI-guided robotic system for transperineal prostate interventions: proof of principlePhysics in Medicine & Biology, 2010
- Transperineal Prostate Intervention: Robot for Fully Automated MR Imaging—System Description and Proof of Principle in a Canine ModelRadiology, 2008
- AN IMAGE-GUIDED MAGNETIC RESONANCE-COMPATIBLE SURGICAL ROBOTNeurosurgery, 2008
- Magnetic Resonance–Compatible Robotic and Mechatronics Systems for Image-Guided Interventions and Rehabilitation: A Review StudyAnnual Review of Biomedical Engineering, 2007
- Nonholonomic Modeling of Needle SteeringThe International Journal of Robotics Research, 2006
- Minimally invasive diagnostics and treatment using micro/nano machiningMinimally Invasive Therapy & Allied Technologies, 2006
- Rapid fabrication of a non‐assembly robotic hand with embedded componentsAssembly Automation, 2004