Breed‐Specific Relationship Between Rebound Tonometers ( TonoVet and TonoVet Plus) in Labrador Retrievers
- 9 August 2026
- journal article
- research article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (5) , e70245
Abstract
Objective: This study aimed to characterize the relationship between intraocular pressure (IOP) measurements obtained using two rebound tonometers (TonoVet and TonoVet Plus) in Labrador retrievers and to evaluate a regression‐based approximation for supporting longitudinal interpretation following device replacement. Animals Studied: Fifty‐three clinically normal Labrador retrievers (106 eyes), including guide dog candidates and breeding dogs undergoing routine health screening in Japan, were included. Procedures: IOP was measured sequentially using the TonoVet and TonoVet Plus, both set to dog mode. The first of three readings per eye per device was used for analysis. Measurement order effects were assessed in a separate cohort. Statistical analyses included paired t ‐tests, Pearson's correlation coefficient, and Bland–Altman analysis. Deming regression was used to derive a regression‐based approximation accounting for measurement error in both devices. Results: Measurement order did not significantly influence IOP values. The TonoVet Plus yielded significantly higher IOP values than the TonoVet ( p < 0.0001), and a moderate positive correlation was observed between the two devices ( r = 0.69). Bland–Altman analysis demonstrated a systematic bias (mean difference + 4.5 mmHg; 95% limits of agreement, 1.3 to 7.7 mmHg). Deming regression yielded a slope of 1.05 and an intercept of 3.52. Age‐related effects on IOP were small and not statistically significant. Conclusions: The TonoVet Plus systematically measures higher IOP values than the TonoVet in Labrador retrievers. The derived breed‐specific approximation may support longitudinal interpretation rather than precise individual‐level prediction in comparable clinical settings; however, external validation in independent Labrador retriever populations is warranted.Keywords
This publication has 16 references indexed in Scilit:
- Intraocular Pressure Increase Induced by 0.5% Tropicamide‐0.5% Phenylephrine in Dogs: An Analysis of Causes Using Ultrasound BiomicroscopyVeterinary Ophthalmology, 2025
- Validation of Recalibrated TONOVET Plus and TONOVET Pro in Canine Eyes Compared to Manometer and TONOVETVeterinary Ophthalmology, 2025
- Intereye Differences in the Clinical Assessment of Intraocular Pressure and Ocular BiomechanicsOptometry and Vision Science, 2023
- The effect of central corneal thickness on intraocular pressure values using various tonometers in the dogVeterinary Ophthalmology, 2021
- Intraocular pressure measurements using the TONOVET® rebound tonometer: Influence of the probe‐cornea distanceVeterinary Ophthalmology, 2020
- Estimation of intraocular pressure in normal canine eyes utilizing the newly introduced TonoVet Plus and TonoPen Avia, and their comparison to the established TonoVetVeterinary Ophthalmology, 2020
- Diurnal variations in intraocular pressure and central corneal thickness and the correlation between these factors in dogsVeterinary Ophthalmology, 2017
- Design of an intraocular pressure curve protocol for use in dogsJournal of Small Animal Practice, 2016
- Clinical comparison of theTonoVet®rebound tonometer and theTono‐PenVet®applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathologyVeterinary Ophthalmology, 2013
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005