RBRalf Bieger

Ralf Bieger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ralf Bieger has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mid-term migration pattern of a calcar-guided short stem: A five-year EBRA-FCA-study

    by Karl Philipp Kutzner, Emanuel Ried, Stefanie Donner, Ralf Bieger, Joachim Pfeil, Tobias Freitag


  • Open Access

    Outcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCA

    by Karl Philipp Kutzner, Tobias Freitag, Stefanie Donner, Mark Predrag Kovacevic, Ralf Bieger

    Introduction The principle of implanting a calcar-guided short stem consists of an individual alignment alongside the medial calcar providing the ability of reconstructing varus and valgus anatomy in a great variety. However, still, there are broad concerns about the safety of extensive varus and valgus positioning in regard to stability, bony alterations, and periprosthetic fractures. Materials and methods 216 total hip arthroplasties using a calcar-guided short stem (optimys, Mathys Ltd.) in 162 patients were included. Depending on postoperative CCD angle, hips were divided into five groups (A–E). Varus- and valgus tilt and axial subsidence were assessed by “Einzel-Bild-Roentgen-Analyse”(EBRA-FCA, femoral component analysis) over a 2-year follow-up. The incidence of stress-shielding and cortical hypertrophy as well as clinical outcome [Harris Hip Score (HHS)] were reported. Results Postoperative CCD angles ranged from 117.9° to 145.6° and mean postoperative CCD angles in group A–E were 123.3°, 128.0°, 132.4°, 137.5°, and 142.5°, respectively. After 2 years, the mean varus/valgus tilt was −0.16°, 0.37°, 0.48°, 0.01°, and 0.86°, respectively (p = 0.502). Axial subsidence after 2 years was 1.20, 1.02, 1.44, 1.50, and 2.62 mm, respectively (p = 0.043). No periprosthetic fractures occurred and none of the stems had to be revised. Rates of stress-shielding and cortical hypertrophy as well as HHS showed no significant difference between the groups. Conclusions Valgus alignment results in increased subsidence but does not affect the clinical outcome. There is no difference in stress shielding and cortical hypertrophy between the groups. The authors recommend long term monitoring of valgus aligned stems.


  • Open Access

    Influence of patient-related characteristics on early migration in calcar-guided short-stem total hip arthroplasty: a 2-year migration analysis using EBRA-FCA

    by Karl Philipp Kutzner, Mark Predrag Kovacevic, Tobias Freitag, Andreas Fuchs, Heiko Reichel, Ralf Bieger

    Short stems have gained popularity in recent years. Because of encouraging clinical results, indications have been expended from young to elderly and obese patients. However, long-term results are lacking. The purpose of this study was to evaluate the influence of gender, age, body weight, body mass index (BMI), and offset version on short-stem migration in correlation to the clinical outcome. The implant migration of 202 metaphyseal-anchoring, calcar-guided short stems in 151 patients was assessed by “Einzel-Bild-Roentgen-Analyse” femoral component analysis (EBRA-FCA, femoral component analysis) in a 2-year follow-up. Full weight bearing was allowed directly after surgery. Patients were divided into groups regarding gender, age, body weight, BMI, and offset version. The Harris hip score (HHS) and satisfaction on visual analogue scale (VAS) were analyzed. After 2 years, mean axial subsidence of all 202 implants was 1.43 mm (standard deviation, SD 1.45 mm). A continuous reduction of initially pronounced subsidence over time could be observed. None of the stems had to be revised. Statistically significant increased rates of subsidence were seen in male (1.68 mm; SD 1.56 mm; p = 0.005) and heavy patients (1.54 mm; SD 1.48 mm; p = 0.022). No differences in implant migration were found regarding age, BMI, and different offset versions. HHS improved markedly from 45.8 (SD 15.9) to 98.1 (SD 4.7) while satisfaction on VAS improved from 1.8 (SD 2.2) to 9.7 (SD 0.9) after 2 years. The results suggest a migration pattern with initially pronounced subsidence followed by subsequent stabilization. Male and obese patients show a slightly increased initial subsidence without any signs of sustained micromovement. No correlation was found concerning clinical results and pronounced initial subsidence above the threshold of 1.5 mm. No aseptic loosening or other signs of implant failure were seen within the observation period of 2 years. German Clinical Trials Register, DRKS00009834 .


  • Erkennung von Hüftschaftsinterungen am Röntgenbild

    by R. Bieger, B. Cakir, H. Reichel, T. Kappe

    Bei jährlich über 150.000 Hüftprothesenimplantationen in Deutschland ist die radiologische Beurteilung der Stabilität von Hüfttotalendoprothesenschäften eine Fragestellung der täglichen Praxis. Unklar ist, welche Referenzpunkte zur Beurteilung des stabilen Sitzes eines Prothesenschafts Verwendung finden sollten und wann eine Schaftsinterung vorliegt. Ziel dieser Studie war es, die Reliabilität von radiologischen Referenzpunkten am Prothesenschaft und dem periprothetischen Knochen zu untersuchen und einen Referenzwert für die Stabilität eines Implantats zu ermitteln. Auf 44 Beckenübersichtsaufnahmen wurden von zwei Beobachtern die knöchernen Landmarken des Trochanter major und minor und endoprothesenseitig die Prothesenschulter, die Prothesenspitze und der Hüftkopfmittelpunkt bestimmt. Die Messungen wurden sowohl digital als auch manuell durchgeführt und statistisch die Intraobserverreliabilität ermittelt. Manuell zeigte sich der Trochanter major und digital der Trochanter minor als knöcherner Referenzpunkt mit der höchsten Reproduzierbarkeit. Auf Seiten des Implantats erbrachte die Bestimmung der Prothesenschulter die geringste Ungenauigkeit. Insgesamt zeigte sich die manuelle Messung genauer als die digitale mit einem bestmöglichen 95 %-Konfidenzintervall von ± 2 mm für die Distanz zwischen Trochanter major und Prothesenschulter. Als Referenz für die Analyse von Endoprothesenschäften empfehlen wir die Distanz zwischen Prothesenschulter und Trochanter major am nativen und zwischen Prothesenschulter und Trochanter minor am digitalen Röntgenbild. Eine echte Sinterung sollte referenzspezifisch erst ab einer gemessenen Migration > 2 mm angegeben werden. In Germany, more than 150,000 total hip arthroplasties (THA) are performed annually. Early implant migration is supposed to be the best indicator for mechanical failure of femoral stems. Therefore, radiological evaluation of hip stems is routinely done by analyzing plain radiographs of THA. The purpose of this study was to evaluate the accuracy of implant migration measurement on plain radiographs. Two observers analyzed 44 anterior–posterior radiographs of the pelvis in 22 pain-free patients at least 2 years after implantation of an anatomical hip stem. The evaluation was performed on digital as well as conventional plain radiographs. Intraobserver reliability was analyzed by double measurements of each radiograph and the evaluation of the consecutive series of each patient. The anatomical structures of interest were the greater trochanter and the minor trochanter. Furthermore, the tip of the prosthesis, the shoulder of the implant, and the center of rotation were determined. The conventional measurement technique proved higher accuracy compared to the digital measurement technique. The best anatomical structure was the greater trochanter in the conventional technique and the minor trochanter in the digital technique. The best reference structure with regard to the implant was the shoulder of the prosthesis for both techniques. The recommended reference structures for the evaluation of implant migration on plain radiographs are the greater trochanter and the shoulder of the implant for the conventional measurement technique and the minor trochanter and the shoulder of the implant for the digital technique. Migration of an implant should not assumed before a determined difference of 2 mm.