Stefanie Donner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Stefanie Donner has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Karl Philipp Kutzner
Klinik für Orthopädie und Unfallchirurgie, St Josefs Hospital Wiesbaden GmbH, Wiesbaden, Deutschland
2 shared publications - Ralf Bieger
Department of Orthopaedic Surgery, University of Ulm (RKU), Oberer Eselsberg 45, 89081, Ulm, Germany
2 shared publications - Tobias Freitag
Department of Orthopaedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
2 shared publications - Emanuel Ried
Division of Trauma Surgery, University Hospital Zürich (USZ), University of Zürich, Rämistr. 100. 8091 Zürich, Switzerland
1 shared publication - Joachim Pfeil
Chefarzt, Orthopädische Klinik, St. Josefs-Hospital
1 shared publication Mark Predrag Kovacevic
Department of Traumatology, Hand- and Orthopaedic Surgery, HELIOS Dr. Horst Schmidt Clinic Wiesbaden, Ludwig-Erhard-Str. 100, 65199, Wiesbaden, Germany
1 shared publication
Latest Publications
- Open Access
- 1 November 2020
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 25 (6) , 1015-1020
Mid-term migration pattern of a calcar-guided short stem: A five-year EBRA-FCA-study
- 1 November 2020
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 25 (6) , 1015-1020
Open AccessMid-term migration pattern of a calcar-guided short stem: A five-year EBRA-FCA-study
- Open Access
- 2 February 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (3) , 431-439
Outcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCA
Introduction The principle of implanting a calcar-guided short stem consists of an individual alignment alongside the medial calcar providing the ability of reconstructing varus and valgus anatomy in a great variety. However, still, there are broad concerns about the safety of extensive varus and valgus positioning in regard to stability, bony alterations, and periprosthetic fractures. Materials and methods 216 total hip arthroplasties using a calcar-guided short stem (optimys, Mathys Ltd.) in 162 patients were included. Depending on postoperative CCD angle, hips were divided into five groups (A–E). Varus- and valgus tilt and axial subsidence were assessed by “Einzel-Bild-Roentgen-Analyse”(EBRA-FCA, femoral component analysis) over a 2-year follow-up. The incidence of stress-shielding and cortical hypertrophy as well as clinical outcome [Harris Hip Score (HHS)] were reported. Results Postoperative CCD angles ranged from 117.9° to 145.6° and mean postoperative CCD angles in group A–E were 123.3°, 128.0°, 132.4°, 137.5°, and 142.5°, respectively. After 2 years, the mean varus/valgus tilt was −0.16°, 0.37°, 0.48°, 0.01°, and 0.86°, respectively (p = 0.502). Axial subsidence after 2 years was 1.20, 1.02, 1.44, 1.50, and 2.62 mm, respectively (p = 0.043). No periprosthetic fractures occurred and none of the stems had to be revised. Rates of stress-shielding and cortical hypertrophy as well as HHS showed no significant difference between the groups. Conclusions Valgus alignment results in increased subsidence but does not affect the clinical outcome. There is no difference in stress shielding and cortical hypertrophy between the groups. The authors recommend long term monitoring of valgus aligned stems.
- 2 February 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (3) , 431-439
Open AccessOutcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCA
Introduction The principle of implanting a calcar-guided short stem consists of an individual alignment alongside the medial calcar providing the ability of reconstructing varus and valgus anatomy in a great variety. However, still, there are broad concerns about the safety of extensive varus and valgus positioning in regard to stability, bony alterations, and periprosthetic fractures. Materials and methods 216 total hip arthroplasties using a calcar-guided short stem (optimys, Mathys Ltd.) in 162 patients were included. Depending on postoperative CCD angle, hips were divided into five groups (A–E). Varus- and valgus tilt and axial subsidence were assessed by “Einzel-Bild-Roentgen-Analyse”(EBRA-FCA, femoral component analysis) over a 2-year follow-up. The incidence of stress-shielding and cortical hypertrophy as well as clinical outcome [Harris Hip Score (HHS)] were reported. Results Postoperative CCD angles ranged from 117.9° to 145.6° and mean postoperative CCD angles in group A–E were 123.3°, 128.0°, 132.4°, 137.5°, and 142.5°, respectively. After 2 years, the mean varus/valgus tilt was −0.16°, 0.37°, 0.48°, 0.01°, and 0.86°, respectively (p = 0.502). Axial subsidence after 2 years was 1.20, 1.02, 1.44, 1.50, and 2.62 mm, respectively (p = 0.043). No periprosthetic fractures occurred and none of the stems had to be revised. Rates of stress-shielding and cortical hypertrophy as well as HHS showed no significant difference between the groups. Conclusions Valgus alignment results in increased subsidence but does not affect the clinical outcome. There is no difference in stress shielding and cortical hypertrophy between the groups. The authors recommend long term monitoring of valgus aligned stems.