Hypoxanthine Biosensor Based on Immobilization of Xanthine Oxidase on Modified Pt Electrode and Its Application for Fish Meat
Authors:
- 10 February 2014
- journal article
- research article
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 63 (9) , 476-485
Abstract
In this study, hypoxanthine biosensor based on immobilization of xanthine oxidase on polyvinylferrocenium perchlorate matrix coated Pt electrode for detection of hypoxanthine was presented. The steady-state background current of the biosensor was measured at+0.5V, which was due to the electrooxidation of enzymatically produced H2O2. The biosensor exhibited a linear range from 2.15 × 10−3mM to 1.03mM (r = 0.9963) with a detection limit of 6.5 × 10−4mM (S/N = 3) for the detection of hypoxanthine. The storage stability of the biosensor, the effect of interference by uric acid, and the applicability to fish sample of the biosensor analysis were also evaluated.Keywords
This publication has 46 references indexed in Scilit:
- Highly Sensitive Glucose Sensing With Multi-Walled Carbon Nanotubes – Polyaniline CompositePolymer-Plastics Technology and Engineering, 2012
- Hypoxanthine-based enzymatic sensor for determination of pork meat freshnessFood Chemistry, 2010
- Amperometric Biosensor for Hypoxanthine Based on Immobilized Xanthine Oxidase on Iron (III)Meso‐tetraphenylporphyrin Nanoparticles Modified Glassy Carbon ElectrodeAnalytical Letters, 2008
- Amperometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) filmSensors and Actuators B: Chemical, 2006
- Biosensor Based on Xanthine Oxidase for Monitoring Hypoxanthine in Fish MeatAmerican Journal of Biochemistry and Biotechnology, 2005
- Amperometric on-line sensor for continuous measurement of hypoxanthine based on osmium-polyvinylpyridine gel polymer and xanthine oxidase bienzyme modified glassy carbon electrodeAnalytica Chimica Acta, 2000
- Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized on a CuPtCl6 chemically modified electrode and liquid chromatography electrochemical detectionAnalytica Chimica Acta, 2000
- Biosensor for detection of hypoxanthine based on xanthine oxidase immobilized on chemically modified carbon paste electrodeAnalytica Chimica Acta, 2000
- Evaluation of beef aging by determination of hypoxanthine and xanthine contents: application of a xanthine sensorFood Chemistry, 1995
- Microbial Sensors for the Detection of Fish FreshnessJournal of Food Science, 1987