Effect of preservation on the mechanical properties of 3D printing resins for occlusal splints
Open Access
- 1 January 2025
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e060
Abstract
This study aims to evaluate the mechanical properties of 3D printing resins for occlusal splints (OS) under different preservation conditions based on sleep duration. The study factors (n = 10) included material types: PriZma 3D Bio Splint (PZ), Cosmos Splint (CS), NightGuard Firm (NGF), and self-polymerizing acrylic resin (control group - CG); preservation: artificial saliva (S), natural water (W), 0.12% chlorhexidine (C), and Corega tabs (CTs); and evaluation times: T0 (24 h after fabrication) and 30 d after exposure. Further, the surface roughness (Ra), Knoop microhardness (KH), three-point flexural strength (FS), and flexural modulus (FM) were analyzed. In terms of the time and material, Tukey’s test revealed no significant differences in Ra between the groups at 24 h. After 30 d, PZ showed significantly lower values than the other groups (p < 0.05). For the KH, NGF was significantly higher than that in all groups at 24 h (p < 0.05); after 30 d, the NGF decreased in W and C (p < 0.05), and the NGF and PZ exhibited elevated values in S and CT, respectively. The Kruskal–Wallis test and multiple comparisons showed that the PZ had a higher value at 24 h (p < 0.05). Post 30 d, all 3D-printing resins increased values in CT and S (p < 0.05), and the PZ decreased in the C and W (P < 0.05). Finally, the FM increased under all conditions. The preservation of S and CT partially enhanced the mechanical properties of the OS.Keywords
Funding Information
- CNPq (#408214/2021-0)
This publication has 35 references indexed in Scilit:
- Mechanical and physical properties of splint materials for oral appliances produced by additive, subtractive and conventional manufacturingDental Materials, 2024
- Evaluation of wear behaviour of various occlusal splint materials and manufacturing processesJournal of the Mechanical Behavior of Biomedical Materials, 2022
- Characterization of occlusal splint materials: CAD-CAM versus conventional resinsJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Comparison of hardness and polishability of various occlusal splint materialsJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Evaluation of the mechanical properties and degree of conversion of 3D printed splint materialJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Accuracy and its impact on fit of injection molded, milled and additively manufactured occlusal splintsJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Short‐term effects of NTI‐tss and Michigan splint on nocturnal jaw muscle activity: A pilot studyClinical and Experimental Dental Research, 2020
- Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printingClinical Oral Investigations, 2020
- Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymersOdontology, 2019
- Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging—an in vitro studyClinical Oral Investigations, 2019