Accuracy of Algorithms and Visual Inspection for Detection of Trigger Asynchrony in Critical Patients : A Systematic Review
Authors:
- Monique BandeiraMBMonique Bandeira
- Alícia AlmeidaAAAlícia Almeida
- Lívia MeloLMLívia Melo
- Pedro Henrique de MouraPMPedro Henrique de Moura
- Emanuelle Olympia Ribeiro SilvaESEmanuelle Olympia Ribeiro Silva
- Jakson SilvaJSJakson Silva
- Armèle Dornelas de AndradeAAArmèle Dornelas de Andrade
- Daniella BrandãoDBDaniella Brandão
- Shirley CamposSCShirley Campos
Open Access
- 28 September 2021
- journal article
- review article
- Published by Wiley in Critical Care Research and Practice
- Vol. 2021, 1-5
Abstract
Objective. This study aimed to summarize the accuracy of the different methods for detecting trigger asynchrony at the bedside in mechanically ventilated patients. Method. A systematic review was conducted from 1990 to 2020 in PubMed, Lilacs, Scopus, and ScienceDirect databases. The reference list of the identified studies, reviews, and meta-analyses was also manually searched for relevant studies. The reference standards were esophageal pressure catheter and/or electrical activity of the diaphragm. Studies were assessed following the QUADAS-2 recommendations, while the review was prepared according to the PRISMA criteria. Results. One thousand one hundred and eleven studies were selected, and four were eligible for analysis. Esophageal pressure was the predominant reference standard, while visual inspection and algorithms/software comprised index tests. The trigger asynchrony, ineffective expiratory effort, double triggering, and reverse triggering were analyzed. Sensitivity and specificity ranged from 65.2 to 99 and 80 to 100, respectively. Positive predictive values reached 80.3 to 100, while the negative predictive values reached 92 to 100. Accuracy could not be calculated for most studies. Conclusion. Algorithms/software validated directly or indirectly using reference standards present high sensitivity and specificity, with a diagnostic power similar to visual inspection of experts.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (001, 403341/2020-5, APQ-0249-4.08/20)
- Universidade Federal de Pernambuco (001, 403341/2020-5, APQ-0249-4.08/20)
- UFPE-PROPESQI (001, 403341/2020-5, APQ-0249-4.08/20)
- UFPE PROEXC (001, 403341/2020-5, APQ-0249-4.08/20)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (001, 403341/2020-5, APQ-0249-4.08/20)
- Fundação de Amparo à Ciência e Tecnologia do Estado de Pernambuco (001, 403341/2020-5, APQ-0249-4.08/20)
This publication has 19 references indexed in Scilit:
- Asynchronies during mechanical ventilation are associated with mortalityIntensive Care Medicine, 2015
- Patient ventilator asynchrony in critically ill adults: Frequency and typesHeart & Lung, 2014
- The Application of Esophageal Pressure Measurement in Patients with Respiratory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2014
- Monitoring of the Respiratory Muscles in the Critically IllAmerican Journal of Respiratory and Critical Care Medicine, 2013
- Validation of the Better Care® system to detect ineffective efforts during expiration in mechanically ventilated patients: a pilot studyIntensive Care Medicine, 2012
- Efficacy of ventilator waveforms observation in detecting patient–ventilator asynchrony*Critical Care Medicine, 2011
- The Values and Value of Patient-Centered CareThe Annals of Family Medicine, 2011
- Ineffective triggering predicts increased duration of mechanical ventilation*Critical Care Medicine, 2009
- Detecting ineffective triggering in the expiratory phase in mechanically ventilated patients based on airway flow and pressure deflection: Feasibility of using a computer algorithm*Critical Care Medicine, 2008
- Patient-ventilator asynchrony during assisted mechanical ventilationIntensive Care Medicine, 2006