Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation
Authors:
- Piotr MajPMPiotr Maj
- Grzegorz W. DeptuchGDGrzegorz W. Deptuch
- Dominik S. GorniDGDominik S. Gorni
- Giovanni PinaroliGPGiovanni Pinaroli
- Gabriella A. CariniGCGabriella A. Carini
- David P. SiddonsDSDavid P. Siddons
- Ryan TapperoRTRyan Tappero
- Soumyajit MandalSoumyajit Mandal
- Donald PinelliDPDonald Pinelli
- Timothy KerstenTKTimothy Kersten
- Nicholas St JohnNJNicholas St John
- Abdul K. RumaizARAbdul K. Rumaiz
Open Access
- 1 January 2026
- journal article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 154-161
Abstract
The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu K α), and 138 eV FWHM at 3.69 keV (Ca K α). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.Keywords
Funding Information
- Brookhaven Science Associates LLC (DE-SC0012704)
This publication has 23 references indexed in Scilit:
- EIGER2 hybrid-photon-counting X-ray detectors for advanced synchrotron diffraction experimentsJournal of Synchrotron Radiation, 2023
- Proof of principle study: synchrotron X-ray fluorescence microscopy for identification of previously radioactive microparticles and elemental mapping of FFPE tissuesScientific Reports, 2023
- 20 µs-resolved high-throughput X-ray photon correlation spectroscopy on a 500k pixel detector enabled by data-management workflowJournal of Synchrotron Radiation, 2021
- A coded aperture microscope for X-ray fluorescence full-field imagingJournal of Synchrotron Radiation, 2020
- Compressive Sensing for Dynamic XRF ScanningScientific Reports, 2020
- The ePix10k 2-megapixel hard X-ray detector at LCLSJournal of Synchrotron Radiation, 2020
- Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detectorJournal of Synchrotron Radiation, 2018
- Macro and Micro Full Field X-Ray Fluorescence with an X-Ray Pinhole Camera Presenting High Energy and High Spatial ResolutionAnalytical Chemistry, 2014
- Combining µXANES and µXRD mapping to analyse the heterogeneity in calcium carbonate granules excreted by the earthwormLumbricus terrestrisJournal of Synchrotron Radiation, 2013
- The PILATUS 1M detectorJournal of Synchrotron Radiation, 2006