Abdul K. Rumaiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abdul K. Rumaiz has a total of 208 co-authors. Here are the top co-authors by number of shared publications:
- D. Peter Siddons
NSLS II, Brookhaven National Laboratory, Upton, NY 11973, USA
9 shared publications - Francesca Capocasa
Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA
6 shared publications - Anthony Kuczewski
NSLS-II, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA
4 shared publications - Conan Weiland
Material Measurement Laboratory National Institute of Standards and Technology Gaithersburg Maryland USA
4 shared publications J. C. Woicik
Materials Measurement Science Division, Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
4 shared publicationsAnthony J. Kuczewski
NSLS II, Brookhaven National Laboratory, Upton, NY 11973, USA
3 shared publications
Latest Publications
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06029
Design and characterization of LGADs for photon science
Recent developments in X-ray technology have highlighted a significant gap between the advancements in X-ray facility capabilities and the corresponding limitations in detector/sensor technologies, especially in the soft X-ray energy range (i.e. 200 eV to 2 keV). While hybrid pixel detectors are the standard and well mature for higher-energy X-ray applications (i.e. 2–20 keV), their usage in the soft X-ray regime remains underexplored. The advancement of silicon Low Gain Avalanche Diodes (LGADs), characterized by moderate internal gains in the range of 3–10, have emerged as a promising solution for addressing the signal-to-noise ratio limitations inherent in the soft X-ray regime. However, several challenges remain in optimizing and characterize LGAD technology for this lower energy range. At Brookhaven National Laboratory, we are developing and optimizing a variant of LGAD silicon sensor for hybrid detectors targeting soft X-rays. This work will introduce the challenges and progress of our Detector for Imaging and Noise Attenuation (DIANA). We will discuss optimization strategies and present results from recently developed sensors. Furthermore, we will report on the currently achievable performance and outline future improvements.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06029
Design and characterization of LGADs for photon science
Recent developments in X-ray technology have highlighted a significant gap between the advancements in X-ray facility capabilities and the corresponding limitations in detector/sensor technologies, especially in the soft X-ray energy range (i.e. 200 eV to 2 keV). While hybrid pixel detectors are the standard and well mature for higher-energy X-ray applications (i.e. 2–20 keV), their usage in the soft X-ray regime remains underexplored. The advancement of silicon Low Gain Avalanche Diodes (LGADs), characterized by moderate internal gains in the range of 3–10, have emerged as a promising solution for addressing the signal-to-noise ratio limitations inherent in the soft X-ray regime. However, several challenges remain in optimizing and characterize LGAD technology for this lower energy range. At Brookhaven National Laboratory, we are developing and optimizing a variant of LGAD silicon sensor for hybrid detectors targeting soft X-rays. This work will introduce the challenges and progress of our Detector for Imaging and Noise Attenuation (DIANA). We will discuss optimization strategies and present results from recently developed sensors. Furthermore, we will report on the currently achievable performance and outline future improvements.
- Open Access
- 21 May 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1016-1021
Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure
Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high- Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.
- 21 May 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1016-1021
Open AccessGepta-EX: a multi-channel germanium detector for X-ray absorption fine structure
Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high- Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.
- Open Access
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03014
Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications
High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03014
Open AccessCharacterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications
High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.
- Open Access
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 154-161
Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation
The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu K α), and 138 eV FWHM at 3.69 keV (Ca K α). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 154-161
Open AccessEvaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation
The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu K α), and 138 eV FWHM at 3.69 keV (Ca K α). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.
- Open Access
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 91-97
Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging
We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 91-97
Open AccessGaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging
We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.
- Open Access
- 2 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Tracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy
Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed \(\textrm{Al}_2\) \(\textrm{O}_3\) and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine \(\textrm{Al}_2\) \(\textrm{O}_3\) layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of \(\textrm{Al}_2\) \(\textrm{O}_3\)/MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure \(\textrm{Al}_2\) \(\textrm{O}_3\) layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top \(\textrm{Al}_2\) \(\textrm{O}_3\) layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies.- 2 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessTracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy
Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed \(\textrm{Al}_2\) \(\textrm{O}_3\) and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine \(\textrm{Al}_2\) \(\textrm{O}_3\) layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of \(\textrm{Al}_2\) \(\textrm{O}_3\)/MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure \(\textrm{Al}_2\) \(\textrm{O}_3\) layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top \(\textrm{Al}_2\) \(\textrm{O}_3\) layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies. - Open Access
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10025
High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector
Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10025
Open AccessHigh-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector
Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.
- Open Access
- 16 August 2025
- Published by Springer Nature in Communications Materials
- Vol. 6 (1) , 1-7
Low-loss superconducting resonators fabricated from tantalum films grown at room temperature
The use of α -tantalum in superconducting circuits has enabled a considerable improvement in the coherence time of transmon qubits. The standard approach to grow α -tantalum thin films on silicon involves heating the substrate, which takes several hours per deposition and prevents the integration of this material with wafers containing temperature-sensitive components. We report a detailed experimental study of an alternative growth method of α -tantalum on silicon, which is achieved at room temperature through the use of a niobium seed layer. Despite a substantially higher density of oxygen-rich grain boundaries in the films sputtered at room temperature, resonators made from these films are found to have state-of-the-art quality factors, comparable to resonators fabricated from tantalum grown at high temperature. This finding challenges previous assumptions about correlations between material properties and microwave loss of superconducting thin films, and opens a new avenue for the integration of tantalum into fabrication flows with limited thermal budget.
- 16 August 2025
- Published by Springer Nature in Communications Materials
- Vol. 6 (1) , 1-7
Open AccessLow-loss superconducting resonators fabricated from tantalum films grown at room temperature
The use of α -tantalum in superconducting circuits has enabled a considerable improvement in the coherence time of transmon qubits. The standard approach to grow α -tantalum thin films on silicon involves heating the substrate, which takes several hours per deposition and prevents the integration of this material with wafers containing temperature-sensitive components. We report a detailed experimental study of an alternative growth method of α -tantalum on silicon, which is achieved at room temperature through the use of a niobium seed layer. Despite a substantially higher density of oxygen-rich grain boundaries in the films sputtered at room temperature, resonators made from these films are found to have state-of-the-art quality factors, comparable to resonators fabricated from tantalum grown at high temperature. This finding challenges previous assumptions about correlations between material properties and microwave loss of superconducting thin films, and opens a new avenue for the integration of tantalum into fabrication flows with limited thermal budget.
- 21 July 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 112 (3)
Satellites, core hole excitations, and spin-resolved electronic structure in the spectroscopy of half-metallic- 21 July 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 112 (3)
Satellites, core hole excitations, and spin-resolved electronic structure in the spectroscopy of half-metallic- 18 October 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 42 (6)
Synthesis and electrical transport properties of superconducting platinum silicide thin films and devices
We evaluate the material characteristics of superconducting platinum silicide (PtSi) thin films as candidate materials for superconducting quantum information devices compatible with silicon technology. These films were synthesized using magnetron sputtering under ultrahigh vacuum conditions, followed by rapid thermal annealing. Polycrystalline PtSi films synthesized by this method have the favorable properties of superconducting critical temperature of 0.95 K and relatively long zero-temperature Ginzburg-Landau coherence length of 76 nm. We further studied coplanar microbridge devices fabricated by electron beam lithography and chlorine-free reactive ion etching, finding that the temperature-dependent critical current density follows the Ginzburg Landau depairing mechanism.
- 18 October 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 42 (6)
Synthesis and electrical transport properties of superconducting platinum silicide thin films and devices
We evaluate the material characteristics of superconducting platinum silicide (PtSi) thin films as candidate materials for superconducting quantum information devices compatible with silicon technology. These films were synthesized using magnetron sputtering under ultrahigh vacuum conditions, followed by rapid thermal annealing. Polycrystalline PtSi films synthesized by this method have the favorable properties of superconducting critical temperature of 0.95 K and relatively long zero-temperature Ginzburg-Landau coherence length of 76 nm. We further studied coplanar microbridge devices fabricated by electron beam lithography and chlorine-free reactive ion etching, finding that the temperature-dependent critical current density follows the Ginzburg Landau depairing mechanism.