D. Peter Siddons
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
D. Peter Siddons has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Abdul K. Rumaiz
NSLS-II, Brookhaven National Laboratory, Upton, NY
9 shared publications - Francesca Capocasa
Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA
6 shared publications - Anthony J. Kuczewski
NSLS II, Brookhaven National Laboratory, Upton, NY 11973, USA
3 shared publications - Giovanni Pinaroli
Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973, USA
3 shared publications - Grzegorz Deptuch
Brookhaven National Laboratory
3 shared publications - Piotr Maj
Instrumentation Department, Brookhaven National Laboratory, Upton, NY 11973-5000, U.S.A.
3 shared publications
Latest Publications
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06029
Design and characterization of LGADs for photon science
Recent developments in X-ray technology have highlighted a significant gap between the advancements in X-ray facility capabilities and the corresponding limitations in detector/sensor technologies, especially in the soft X-ray energy range (i.e. 200 eV to 2 keV). While hybrid pixel detectors are the standard and well mature for higher-energy X-ray applications (i.e. 2–20 keV), their usage in the soft X-ray regime remains underexplored. The advancement of silicon Low Gain Avalanche Diodes (LGADs), characterized by moderate internal gains in the range of 3–10, have emerged as a promising solution for addressing the signal-to-noise ratio limitations inherent in the soft X-ray regime. However, several challenges remain in optimizing and characterize LGAD technology for this lower energy range. At Brookhaven National Laboratory, we are developing and optimizing a variant of LGAD silicon sensor for hybrid detectors targeting soft X-rays. This work will introduce the challenges and progress of our Detector for Imaging and Noise Attenuation (DIANA). We will discuss optimization strategies and present results from recently developed sensors. Furthermore, we will report on the currently achievable performance and outline future improvements.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06029
Design and characterization of LGADs for photon science
Recent developments in X-ray technology have highlighted a significant gap between the advancements in X-ray facility capabilities and the corresponding limitations in detector/sensor technologies, especially in the soft X-ray energy range (i.e. 200 eV to 2 keV). While hybrid pixel detectors are the standard and well mature for higher-energy X-ray applications (i.e. 2–20 keV), their usage in the soft X-ray regime remains underexplored. The advancement of silicon Low Gain Avalanche Diodes (LGADs), characterized by moderate internal gains in the range of 3–10, have emerged as a promising solution for addressing the signal-to-noise ratio limitations inherent in the soft X-ray regime. However, several challenges remain in optimizing and characterize LGAD technology for this lower energy range. At Brookhaven National Laboratory, we are developing and optimizing a variant of LGAD silicon sensor for hybrid detectors targeting soft X-rays. This work will introduce the challenges and progress of our Detector for Imaging and Noise Attenuation (DIANA). We will discuss optimization strategies and present results from recently developed sensors. Furthermore, we will report on the currently achievable performance and outline future improvements.
- Open Access
- 21 May 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1016-1021
Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure
Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high- Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.
- 21 May 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1016-1021
Open AccessGepta-EX: a multi-channel germanium detector for X-ray absorption fine structure
Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high- Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.
- Open Access
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03014
Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications
High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03014
Open AccessCharacterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications
High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.
- Open Access
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 154-161
Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation
The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu K α), and 138 eV FWHM at 3.69 keV (Ca K α). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 154-161
Open AccessEvaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation
The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu K α), and 138 eV FWHM at 3.69 keV (Ca K α). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.
- Open Access
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 91-97
Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging
We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.
- 1 January 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 91-97
Open AccessGaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging
We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.
- Open Access
- 2 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Tracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy
Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed \(\textrm{Al}_2\) \(\textrm{O}_3\) and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine \(\textrm{Al}_2\) \(\textrm{O}_3\) layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of \(\textrm{Al}_2\) \(\textrm{O}_3\)/MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure \(\textrm{Al}_2\) \(\textrm{O}_3\) layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top \(\textrm{Al}_2\) \(\textrm{O}_3\) layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies.- 2 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessTracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy
Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed \(\textrm{Al}_2\) \(\textrm{O}_3\) and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine \(\textrm{Al}_2\) \(\textrm{O}_3\) layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of \(\textrm{Al}_2\) \(\textrm{O}_3\)/MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure \(\textrm{Al}_2\) \(\textrm{O}_3\) layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top \(\textrm{Al}_2\) \(\textrm{O}_3\) layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies. - Open Access
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10025
High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector
Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10025
Open AccessHigh-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector
Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , C04035
Integration of EDWARD readout architecture in full-field fluorescence imaging detector
Data bandwidth, timing resolution and resource utilization in readouts of radiation detectors are a constant challenge. Event driven solutions are pushing against well-trenched framed solutions. The idea for an asynchronous readout architecture called EDWARD (Event-Driven With Access and Reset Decoder) was presented at the TWEPP 2021 conference. Here we show the progress of our work which resulted in two chip prototypes. The first one, named 3FI65P1, is a full device with the analog pixel circuitry suited for full-field fluorescence imaging. It is already manufactured, and preliminary results are presented. The second chip, named EDWARD65P1, contains digital pulse generators with Poisson-exponential distribution in each pixel for extraction of the performance matrix of the EDWARD architecture alone.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , C04035
Integration of EDWARD readout architecture in full-field fluorescence imaging detector
Data bandwidth, timing resolution and resource utilization in readouts of radiation detectors are a constant challenge. Event driven solutions are pushing against well-trenched framed solutions. The idea for an asynchronous readout architecture called EDWARD (Event-Driven With Access and Reset Decoder) was presented at the TWEPP 2021 conference. Here we show the progress of our work which resulted in two chip prototypes. The first one, named 3FI65P1, is a full device with the analog pixel circuitry suited for full-field fluorescence imaging. It is already manufactured, and preliminary results are presented. The second chip, named EDWARD65P1, contains digital pulse generators with Poisson-exponential distribution in each pixel for extraction of the performance matrix of the EDWARD architecture alone.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (1) , 015305
Interface formation and Schottky barrier height for Y, Nb, Au, and Pt on Ge as determined by hard x-ray photoelectron spectroscopy
Development of a robust, thin, hole-blocking (n+) contact on high purity germanium (HPGe) has been the main challenge in the development of Ge-based radiation sensors. Yttrium has been reported to be a viable hole-blocking contact on HPGe, and detectors with low leakage have been fabricated. Niobium has also been considered as a potential hole-blocking contact due to its low work function. Here, we investigate interface chemistry and the Schottky barrier height of Y and Nb, as well as electron-blocking contacts Au and Pt, on Ge(100) surfaces using hard x-ray photoelectron spectroscopy. We find a barrier height of 1.05 ± 0.10 eV for Y/HPGe, confirming the formation of a hole-blocking barrier. For Nb/HPGe, the barrier height of 0.13 ± 0.10 eV demonstrates that the interface is not hole-blocking. The Schottky barrier of Au and Pt was found to be 0.45 ± 0.10 and 0.51 ± 0.10 eV, respectively.
- 1 January 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (1) , 015305
Open AccessInterface formation and Schottky barrier height for Y, Nb, Au, and Pt on Ge as determined by hard x-ray photoelectron spectroscopy
Development of a robust, thin, hole-blocking (n+) contact on high purity germanium (HPGe) has been the main challenge in the development of Ge-based radiation sensors. Yttrium has been reported to be a viable hole-blocking contact on HPGe, and detectors with low leakage have been fabricated. Niobium has also been considered as a potential hole-blocking contact due to its low work function. Here, we investigate interface chemistry and the Schottky barrier height of Y and Nb, as well as electron-blocking contacts Au and Pt, on Ge(100) surfaces using hard x-ray photoelectron spectroscopy. We find a barrier height of 1.05 ± 0.10 eV for Y/HPGe, confirming the formation of a hole-blocking barrier. For Nb/HPGe, the barrier height of 0.13 ± 0.10 eV demonstrates that the interface is not hole-blocking. The Schottky barrier of Au and Pt was found to be 0.45 ± 0.10 and 0.51 ± 0.10 eV, respectively.
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-11
An on-chip charge cluster reconstruction technique in the miniVIPIC pixel readout chip for X-ray counting and timing
An on-chip algorithm for the allocation of a hit to a single pixel in the presence of charge sharing in a highly segmented pixel detector is presented. It has been developed to advance pixel detector technology for experiments with X-ray beams at a synchrotron facility. Its key elements are: activation of groups of pixels (neighborhood_active), comparisons of peak amplitudes within the active neighborhood, virtual pixels that recover composite signals, ability to create event driven strobes to control comparisons of fractional signals between neighboring pixels and finally latching of the results of these comparisons. The miniVIPIC prototype was designed in a 130 nm process, as a proof of feasibility. The chip contains an array of 32×32 100×100 μm 2 pixels. Analog and digital signals are exchanged between pixels, forming an extensive inter-pixel connection grid, whose routing to minimize parasistics, represented the major challenge. The design details of the chip are provided.
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-11
An on-chip charge cluster reconstruction technique in the miniVIPIC pixel readout chip for X-ray counting and timing
An on-chip algorithm for the allocation of a hit to a single pixel in the presence of charge sharing in a highly segmented pixel detector is presented. It has been developed to advance pixel detector technology for experiments with X-ray beams at a synchrotron facility. Its key elements are: activation of groups of pixels (neighborhood_active), comparisons of peak amplitudes within the active neighborhood, virtual pixels that recover composite signals, ability to create event driven strobes to control comparisons of fractional signals between neighboring pixels and finally latching of the results of these comparisons. The miniVIPIC prototype was designed in a 130 nm process, as a proof of feasibility. The chip contains an array of 32×32 100×100 μm 2 pixels. Analog and digital signals are exchanged between pixels, forming an extensive inter-pixel connection grid, whose routing to minimize parasistics, represented the major challenge. The design details of the chip are provided.