Matthew J. DiDomizio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew J. DiDomizio has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Adam Barowy
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
2 shared publications - Gavin P. Horn
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
2 shared publications - Jason Floyd
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
2 shared publications - Jonathan L. Hodges
JENSEN HUGHES
2 shared publications - Nathaniel G. Sauer
UL Research Institutes, Fire Safety Research Institute, 6200 Old Dobbin Lane, Suite 150, Columbia, MD 21045, United States
2 shared publications - Parham Dehghani
UL Research Institutes, Fire Safety Research Institute, 6200 Old Dobbin Lane, Suite 150, Columbia, MD 21045, United States
2 shared publications
Latest Publications
- Open Access
- 2 April 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (3) , 66
Thermal Hazards from Electric Vehicle Fires: Experimental Data and Predictive Model
- 2 April 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (3) , 66
Open AccessThermal Hazards from Electric Vehicle Fires: Experimental Data and Predictive Model
- Open Access
- 11 March 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 162
Probabilistic design fire scenarios for performance-based design involving passenger vehicles
- 11 March 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 162
Open AccessProbabilistic design fire scenarios for performance-based design involving passenger vehicles
- Open Access
- 16 January 2026
- Published by Elsevier in Data in Brief
- Vol. 65, 112471
Measurement data from full-scale fire experiments of battery electric vehicles and internal combustion engine vehicles
- 16 January 2026
- Published by Elsevier in Data in Brief
- Vol. 65, 112471
Open AccessMeasurement data from full-scale fire experiments of battery electric vehicles and internal combustion engine vehicles
- Open Access
- 2 June 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 250
Toward grid-independent modeling of natural convection with fire dynamics simulator
- 2 June 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 250
Open AccessToward grid-independent modeling of natural convection with fire dynamics simulator
- Open Access
- 26 February 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 153
Separation of heat transfer modes in fire: Review and analysis
- 26 February 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 153
Open AccessSeparation of heat transfer modes in fire: Review and analysis
- Open Access
- 8 January 2025
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 2361-2387
Experimental Study of Heat Transfer Through Windows Exposed to a Radiant Panel Heater
Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23 cm by 23 cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10 $$\hbox {kW/m}^{2}$$ , 20 $$\hbox {kW/m}^{2}$$ , 30 $$\hbox {kW/m}^{2}$$ , 40 $$\hbox {kW/m}^{2}$$ , and 50 $$\hbox {kW/m}^{2}$$ . Total heat flux was measured 5.1 cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles.- 8 January 2025
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 2361-2387
Open AccessExperimental Study of Heat Transfer Through Windows Exposed to a Radiant Panel Heater
Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23 cm by 23 cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10 $$\hbox {kW/m}^{2}$$ , 20 $$\hbox {kW/m}^{2}$$ , 30 $$\hbox {kW/m}^{2}$$ , 40 $$\hbox {kW/m}^{2}$$ , and 50 $$\hbox {kW/m}^{2}$$ . Total heat flux was measured 5.1 cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles. - Open Access
- 29 July 2024
- Published by Wiley in Fire and Materials
- Vol. 48 (8) , 796-810
Measurement of thermal conductivity of thermally reactive materials for use in pyrolysis models
Pyrolysis models are used in the fire science field to simulate the thermal decomposition of materials. These models require knowledge of the kinetic and thermodynamic parameters of an assumed reaction mechanism, and the thermophysical properties of the virgin material and product species. Standard test methods exist for measuring the thermal conductivity of nonreactive materials, but to date no suitable method exists that is compatible with contemporary pyrolysis models and is applicable to thermally reactive materials. In the present study, a modified methodology was presented and evaluated to address this need. The methodology involves a preliminary assessment of thermal stability, followed by a series of tests including: thermogravimetric analysis, differential scanning calorimetry, and laser flash analysis. Once a reaction mechanism has been identified, gram‐scale samples of the virgin and stable product species are isolated and independent measurements of thermal conductivity of those species are obtained. The methodology was applied to eucalyptus fiber hardboard, for which a complete set of property data for pyrolysis modeling was obtained. A pyrolysis experiment was then conducted, and that experiment was simulated using a pyrolysis model parameterized with the measured property data. Model predictions of the mass loss rate and temperature rise of a hardboard sample exposed to radiant heat flux of 35 and 60 kW m−2 were found to be a good match to measurements. These results demonstrate the suitability of the property data, the pyrolysis model, and the utility of this approach. This work will serve as a basis for property determination in future pyrolysis studies.
- 29 July 2024
- Published by Wiley in Fire and Materials
- Vol. 48 (8) , 796-810
Open AccessMeasurement of thermal conductivity of thermally reactive materials for use in pyrolysis models
Pyrolysis models are used in the fire science field to simulate the thermal decomposition of materials. These models require knowledge of the kinetic and thermodynamic parameters of an assumed reaction mechanism, and the thermophysical properties of the virgin material and product species. Standard test methods exist for measuring the thermal conductivity of nonreactive materials, but to date no suitable method exists that is compatible with contemporary pyrolysis models and is applicable to thermally reactive materials. In the present study, a modified methodology was presented and evaluated to address this need. The methodology involves a preliminary assessment of thermal stability, followed by a series of tests including: thermogravimetric analysis, differential scanning calorimetry, and laser flash analysis. Once a reaction mechanism has been identified, gram‐scale samples of the virgin and stable product species are isolated and independent measurements of thermal conductivity of those species are obtained. The methodology was applied to eucalyptus fiber hardboard, for which a complete set of property data for pyrolysis modeling was obtained. A pyrolysis experiment was then conducted, and that experiment was simulated using a pyrolysis model parameterized with the measured property data. Model predictions of the mass loss rate and temperature rise of a hardboard sample exposed to radiant heat flux of 35 and 60 kW m−2 were found to be a good match to measurements. These results demonstrate the suitability of the property data, the pyrolysis model, and the utility of this approach. This work will serve as a basis for property determination in future pyrolysis studies.
- 9 July 2024
- Published by Underwriters Laboratories Inc.
Measurement of Heat Transfer and Fire Damage Patterns on Walls for Fire Model Validation
Fire models are presently employed by fire investigators to make predictions of fire dynamics within structures. Predictions include the evolution of gas temperatures and velocities, smoke movement, fire growth and spread, and thermal exposures to surrounding objects, such as walls. Heat flux varies spatially over exposed walls based on the complex thermal interactions within the fire environment, and is the driving factor for thermally induced fire damage. A fire model predicts the temperature and heat transfer through walls based on field predictions, such as radiative and convective heat flux, and is also subject to the boundary condition represen- tation, which is at the discretion of model practitioners. At the time of writing, Fire Dynamics Simulator can represent in-depth heat transfer through walls, and transverse heat transfer is in a preliminary development stage. Critically, limited suitable data exists for validation of heat trans- fer through walls exposed to fires. Mass loss and discoloration fire effects are directly related to the heat transfer and thermal decomposition of walls, therefore it is crucial that the representation of transverse heat transfer in walls in fire models be validated to ensure that fire investigators can produce accurate simulations and reconstructions with these tools. The purpose of this study was to conduct a series of experiments to obtain data that addresses three validation spaces: 1) thermal exposure to walls from fires; 2) heat transfer within walls exposed to fires; and 3) fire damage patterns arising on walls exposed to fires. Fire Safety Research Institute, part of UL Research Institutes, in collaboration with the Bureau of Alcohol, Tobacco, Firearms and Explosives Fire Research Laboratory, led this novel research endeavor. Experiments were performed on three types of walls to address the needs in this validation space: 1. Steel sheet (304 stainless steel, 0.793 mm thick, coated in high-emissivity high-temperature paint on both sides). This wall type was used to support the heat flux validation objective. By combining measurements of gas temperatures near the wall with surface temperatures obtained using infrared thermography, estimates of the incident heat flux to the wall were produced. 2. Calcium silicate board (BNZ Marinite I, 12.7 mm thick). This wall type was used to support the heat transfer validation objective. Since calcium silicate board is a noncombustible material with well-characterized thermophysical properties at elevated temperatures, measurements of surface temperature may be used to validate transverse heat transfer in a fire model without the need to account for a decomposition mechanism. 3. Gypsumwallboard(USGSheetrockUltralight,12.7mmthick,coatedinwhitelatexpaintonthe exposed side). This wall type was used to support the fire damage patterns validation objective. Two types of fire effects were considered: 1) discoloration and charring of the painted paper facing of the gypsum wallboard; and 2) mass loss of the gypsum wallboard (which is related to the calcination of the core material). In addition to temperature and heat flux measurements, high resolution photographs of fire patterns were recorded, and mass loss over the entirety of the wall was measured by cutting the wall into smaller samples and measuring the mass of each individual sample.
- 9 July 2024
- Published by Underwriters Laboratories Inc.
Measurement of Heat Transfer and Fire Damage Patterns on Walls for Fire Model Validation
Fire models are presently employed by fire investigators to make predictions of fire dynamics within structures. Predictions include the evolution of gas temperatures and velocities, smoke movement, fire growth and spread, and thermal exposures to surrounding objects, such as walls. Heat flux varies spatially over exposed walls based on the complex thermal interactions within the fire environment, and is the driving factor for thermally induced fire damage. A fire model predicts the temperature and heat transfer through walls based on field predictions, such as radiative and convective heat flux, and is also subject to the boundary condition represen- tation, which is at the discretion of model practitioners. At the time of writing, Fire Dynamics Simulator can represent in-depth heat transfer through walls, and transverse heat transfer is in a preliminary development stage. Critically, limited suitable data exists for validation of heat trans- fer through walls exposed to fires. Mass loss and discoloration fire effects are directly related to the heat transfer and thermal decomposition of walls, therefore it is crucial that the representation of transverse heat transfer in walls in fire models be validated to ensure that fire investigators can produce accurate simulations and reconstructions with these tools. The purpose of this study was to conduct a series of experiments to obtain data that addresses three validation spaces: 1) thermal exposure to walls from fires; 2) heat transfer within walls exposed to fires; and 3) fire damage patterns arising on walls exposed to fires. Fire Safety Research Institute, part of UL Research Institutes, in collaboration with the Bureau of Alcohol, Tobacco, Firearms and Explosives Fire Research Laboratory, led this novel research endeavor. Experiments were performed on three types of walls to address the needs in this validation space: 1. Steel sheet (304 stainless steel, 0.793 mm thick, coated in high-emissivity high-temperature paint on both sides). This wall type was used to support the heat flux validation objective. By combining measurements of gas temperatures near the wall with surface temperatures obtained using infrared thermography, estimates of the incident heat flux to the wall were produced. 2. Calcium silicate board (BNZ Marinite I, 12.7 mm thick). This wall type was used to support the heat transfer validation objective. Since calcium silicate board is a noncombustible material with well-characterized thermophysical properties at elevated temperatures, measurements of surface temperature may be used to validate transverse heat transfer in a fire model without the need to account for a decomposition mechanism. 3. Gypsumwallboard(USGSheetrockUltralight,12.7mmthick,coatedinwhitelatexpaintonthe exposed side). This wall type was used to support the fire damage patterns validation objective. Two types of fire effects were considered: 1) discoloration and charring of the painted paper facing of the gypsum wallboard; and 2) mass loss of the gypsum wallboard (which is related to the calcination of the core material). In addition to temperature and heat flux measurements, high resolution photographs of fire patterns were recorded, and mass loss over the entirety of the wall was measured by cutting the wall into smaller samples and measuring the mass of each individual sample.
- Open Access
- 2 March 2023
- Published by Elsevier in Fire Safety Journal
- Vol. 137
Characterization of high-temperature paints for infrared thermography in fire research
- 2 March 2023
- Published by Elsevier in Fire Safety Journal
- Vol. 137
Open AccessCharacterization of high-temperature paints for infrared thermography in fire research