Artifact‐reduced two‐dimensional cine steady state free precession for myocardial blood‐ oxygen‐level‐dependent imaging
Open Access
- 29 March 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (4) , 863-871
Abstract
Purpose: To minimize image artifacts in long TR cardiac phase‐resolved steady state free precession (SSFP) based blood‐oxygen‐level‐dependent (BOLD) imaging. Materials and Methods: Nine healthy dogs (four male, five female, 20–25 kg) were studied in a clinical 1.5 Tesla MRI scanner to investigate the effect of temporal resolution, readout bandwidth, and motion compensation on long repetition time (TR) SSFP images. Breath‐held 2D SSFP cine sequences with various temporal resolutions (10–204 ms), bandwidths (239–930 Hz/pixel), with and without first‐order motion compensation were prescribed in the basal, mid‐ventricular, and apical along the short axis. Preliminary myocardial BOLD studies in dogs with controllable coronary stenosis were performed to assess the benefits of artifact‐reduction strategies. Results: Shortening the readout time by means of increasing readout bandwidth had no observable reduction in image artifacts. However, increasing the temporal resolution in the presence of first‐order motion compensation led to significant reduction in image artifacts. Preliminary studies demonstrated that BOLD signal changes can be reliably detected throughout the cardiac cycle. Conclusion: Artifact‐reduction methods used in this study provide significant improvement in image quality compared with conventional long TR SSFP BOLD MRI. It is envisioned that the methods proposed here may enable reliable detection of myocardial oxygenation changes throughout the cardiac cycle with long TR SSFP‐based myocardial BOLD MRI. J. Magn. Reson. Imaging 2010;31:863–871. ©2010 Wiley‐Liss, Inc.Keywords
This publication has 17 references indexed in Scilit:
- Parametric dependence of myocardial blood oxygen level dependent, balanced steady‐state free‐precession imaging at 1.5 T: Theory and experimentsMagnetic Resonance in Medicine, 2010
- Modeling SSFP functional MRI contrast in the brainMagnetic Resonance in Medicine, 2008
- Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0T: Theory and experimental evaluation in caninesJournal of Magnetic Resonance Imaging, 2008
- Cardiac Phase-Resolved Blood Oxygen-Sensitive Steady-State Free Precession MRI for Evaluating the Functional Significance of Coronary Artery StenosisInvestigative Radiology, 2007
- Detecting microcirculatory changes in blood oxygen state with steady‐state free precession imagingMagnetic Resonance in Medicine, 2006
- Oxygen‐sensitive contrast in blood for steady‐state free precession imagingMagnetic Resonance in Medicine, 2005
- Dark Flow Artifacts with Steady-State Free Precession Cine MR Technique: Causes and Implications for Cardiac MR ImagingRadiology, 2004
- Flow artifacts in steady‐state free precession cine imagingMagnetic Resonance in Medicine, 2003
- Flow effects in balanced steady state free precession imagingMagnetic Resonance in Medicine, 2003
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001