Harmonic Disturbance Suppression Based on Precise Shaping of Output Impedance at Selected Frequencies for Standalone Voltage Source Inverter
- 1 August 2023
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6963-6975
Abstract
The output impedance of the voltage source inverter (VSI) would degrade the performance of the VSI when the load is connected. A load current feedforward control is usually used to act as a virtual impedance to reduce the output impedance of the VSI and achieve disturbance suppression. However, due to the variation of the frequency characteristics between the implemented feedforward controller and the theoretical feedforward controller, the output impedance of the VSI cannot be reduced to a lower level, especially the output impedance at harmonic frequencies. In this paper, to improve the performance of harmonic disturbance suppression, the method of precise shaping of output impedance at selected frequencies is proposed for the VSI. By introducing multiple resonant controllers into the load current feedforward control with the consideration of the interaction among the resonant controllers, the variation of the frequency characteristics mentioned above can be compensated accurately at selected frequencies. Then the output impedance of the VSI is further reduced at selected frequencies (including harmonic frequencies), and the performance of the VSI under nonlinear load condition is further improved.Keywords
This publication has 28 references indexed in Scilit:
- New Perspectives on Droop Control in AC MicrogridIEEE Transactions on Industrial Electronics, 2017
- An Enhanced Power Sharing Scheme for Voltage Unbalance and Harmonics Compensation in an Islanded AC MicrogridIEEE Transactions on Energy Conversion, 2016
- Mitigation of Harmonics in Grid-Connected and Islanded Microgrids Via Virtual Admittances and ImpedancesIEEE Transactions on Smart Grid, 2015
- Grid Harmonics Suppression Scheme for LCL-Type Grid-Connected Inverters Based on Output Admittance RevisionIEEE Transactions on Sustainable Energy, 2015
- Load disturbance suppression for voltage‐controlled three‐phase voltage source inverter with transformerIET Power Electronics, 2014
- Voltage unbalance and harmonics compensation for islanded microgrid invertersIET Power Electronics, 2014
- Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled Single Phase Islanded MicrogridsIEEE Transactions on Smart Grid, 2014
- Full-Feedforward Schemes of Grid Voltages for a Three-Phase $LCL$-Type Grid-Connected InverterIEEE Transactions on Industrial Electronics, 2012
- Performance Analysis and Improvement of Digital Controlled Inverter2006
- Control topology options for single-phase UPS invertersIEEE Transactions on Industry Applications, 1997