Hong Ze Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hong Ze Xu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bowei Lin
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Kai Yu
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Li Peng
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication Meng Nan Zhang
Beijing Jiaotong University
1 shared publication- Peng Zhou
University of South Australia
1 shared publication
Latest Publications
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6963-6975
Harmonic Disturbance Suppression Based on Precise Shaping of Output Impedance at Selected Frequencies for Standalone Voltage Source Inverter
The output impedance of the voltage source inverter (VSI) would degrade the performance of the VSI when the load is connected. A load current feedforward control is usually used to act as a virtual impedance to reduce the output impedance of the VSI and achieve disturbance suppression. However, due to the variation of the frequency characteristics between the implemented feedforward controller and the theoretical feedforward controller, the output impedance of the VSI cannot be reduced to a lower level, especially the output impedance at harmonic frequencies. In this paper, to improve the performance of harmonic disturbance suppression, the method of precise shaping of output impedance at selected frequencies is proposed for the VSI. By introducing multiple resonant controllers into the load current feedforward control with the consideration of the interaction among the resonant controllers, the variation of the frequency characteristics mentioned above can be compensated accurately at selected frequencies. Then the output impedance of the VSI is further reduced at selected frequencies (including harmonic frequencies), and the performance of the VSI under nonlinear load condition is further improved.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6963-6975
Harmonic Disturbance Suppression Based on Precise Shaping of Output Impedance at Selected Frequencies for Standalone Voltage Source Inverter
The output impedance of the voltage source inverter (VSI) would degrade the performance of the VSI when the load is connected. A load current feedforward control is usually used to act as a virtual impedance to reduce the output impedance of the VSI and achieve disturbance suppression. However, due to the variation of the frequency characteristics between the implemented feedforward controller and the theoretical feedforward controller, the output impedance of the VSI cannot be reduced to a lower level, especially the output impedance at harmonic frequencies. In this paper, to improve the performance of harmonic disturbance suppression, the method of precise shaping of output impedance at selected frequencies is proposed for the VSI. By introducing multiple resonant controllers into the load current feedforward control with the consideration of the interaction among the resonant controllers, the variation of the frequency characteristics mentioned above can be compensated accurately at selected frequencies. Then the output impedance of the VSI is further reduced at selected frequencies (including harmonic frequencies), and the performance of the VSI under nonlinear load condition is further improved.
- 1 June 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 267, 211-216
Train Optimal Control Strategy on Continuous Change Gradient Steep Downgrades
Reducing the traction energy consumption plays an important role in railway energy saving. Viewed from the present research situation--the models were all based on the train without energy-feedback, moreover the line condition is the fixed steep down or steep up grades, the train group energy control strategy on continuous change gradient steep downgrades with the energy-feedback is proposed. The advantage for energy-saving of the strategy is proved through the traction calculation in theory. On that basis the optimization method is applied to get the optimal strategy balancing the operation time and energy consumption. By comparing the traditional control strategy with the optimal control strategy, the experiments show that the optimal overall target index of the operation time and energy consumption is much better.
- 1 June 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 267, 211-216
Train Optimal Control Strategy on Continuous Change Gradient Steep Downgrades
Reducing the traction energy consumption plays an important role in railway energy saving. Viewed from the present research situation--the models were all based on the train without energy-feedback, moreover the line condition is the fixed steep down or steep up grades, the train group energy control strategy on continuous change gradient steep downgrades with the energy-feedback is proposed. The advantage for energy-saving of the strategy is proved through the traction calculation in theory. On that basis the optimization method is applied to get the optimal strategy balancing the operation time and energy consumption. By comparing the traditional control strategy with the optimal control strategy, the experiments show that the optimal overall target index of the operation time and energy consumption is much better.