Li Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Li Peng has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Xudong Zou
Huazhong University of Science and Technology
7 shared publications - Huayu Li
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
4 shared publications - Jun Sun
Naval University of Engineering, Wuhan 430033, China
4 shared publications - Lin Song
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
4 shared publications - Yangwei Zhou
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications Yong Kang
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (12) , 21946-21958
Internal Dynamics Identification and Shaping for Stability Enhancement in Grid-Forming MMCs
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41  (12) , 21946-21958
Internal Dynamics Identification and Shaping for Stability Enhancement in Grid-Forming MMCs
- 20 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP  (21686777) , 1
Quantitative Observability of PMSM Inductance Estimation: A Unified Multiscale Framework
The convergence stability and accuracy of PMSM parameter estimation are fundamentally governed by model observability. While fundamental-frequency approaches are established, the theoretical observability of emerging models relying on high-frequency current derivative information remains largely unexplored. This paper proposes a real-time quantitative framework for evaluating the observability of PMSM parameter-estimation basis models within a unified multiscale perspective. The proposed method introduces a condition-number-based metric derived from the information matrix, enabling real-time assessment of model excitation and conditioning. Most existing parameter estimation methods are summarized into three basis models, the fundamental-frequency time-scale model (FFTM), the switching-time-scale full model (STFM), and the virtual voltage vector model (VVVM). These models are comparatively analyzed within this framework. Analytical results reveal the excitation-dependent conditioning characteristics of each model and identify their weakly observable conditions. An adaptive observer guided by the proposed metric is utilized specifically to demonstrate the effectiveness of the observability assessment. Both numerical and experimental results confirm that the proposed criterion provides a reliable and real-time index for model observability evaluation and parameter-identification stability.
- 20 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP  (21686777) , 1
Quantitative Observability of PMSM Inductance Estimation: A Unified Multiscale Framework
The convergence stability and accuracy of PMSM parameter estimation are fundamentally governed by model observability. While fundamental-frequency approaches are established, the theoretical observability of emerging models relying on high-frequency current derivative information remains largely unexplored. This paper proposes a real-time quantitative framework for evaluating the observability of PMSM parameter-estimation basis models within a unified multiscale perspective. The proposed method introduces a condition-number-based metric derived from the information matrix, enabling real-time assessment of model excitation and conditioning. Most existing parameter estimation methods are summarized into three basis models, the fundamental-frequency time-scale model (FFTM), the switching-time-scale full model (STFM), and the virtual voltage vector model (VVVM). These models are comparatively analyzed within this framework. Analytical results reveal the excitation-dependent conditioning characteristics of each model and identify their weakly observable conditions. An adaptive observer guided by the proposed metric is utilized specifically to demonstrate the effectiveness of the observability assessment. Both numerical and experimental results confirm that the proposed criterion provides a reliable and real-time index for model observability evaluation and parameter-identification stability.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75  (00189456) , 9005013
Offline Measurement of PMSM Incremental Inductance via Geometric Fitting of Current Derivatives
Accurate incremental inductance maps of the d-and q-axes underpin model-based predictive control, sensorless operation, and fault diagnosis of permanent-magnet synchronous motors (PMSMs). This paper presents a non-invasive offline measurement technique that exploits the current-derivative transients naturally generated by inverter switching events. By reformulating the discrete switching model in a virtual-voltage-vector-oriented frame, the inductance measurement task becomes a rotor-angle-independent geometric fitting problem. A robust fitting solver with outlier rejection mitigates nonlinear effects such as sensor drift and noise. The method operates on a standard finite-control-set drive and requires no shaft lock, additional signal injection, or extra sensors, yet yields a full-range inductance map. Experimental results on an interior PMSM demonstrate that the calibrated inductance map is in close agreement with finite-element analysis, conforms to the IEEE Std 1812-2023 offline benchmark, and remains consistent with values obtained from a current-derivative-based online estimator.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75  (00189456) , 9005013
Offline Measurement of PMSM Incremental Inductance via Geometric Fitting of Current Derivatives
Accurate incremental inductance maps of the d-and q-axes underpin model-based predictive control, sensorless operation, and fault diagnosis of permanent-magnet synchronous motors (PMSMs). This paper presents a non-invasive offline measurement technique that exploits the current-derivative transients naturally generated by inverter switching events. By reformulating the discrete switching model in a virtual-voltage-vector-oriented frame, the inductance measurement task becomes a rotor-angle-independent geometric fitting problem. A robust fitting solver with outlier rejection mitigates nonlinear effects such as sensor drift and noise. The method operates on a standard finite-control-set drive and requires no shaft lock, additional signal injection, or extra sensors, yet yields a full-range inductance map. Experimental results on an interior PMSM demonstrate that the calibrated inductance map is in close agreement with finite-element analysis, conforms to the IEEE Std 1812-2023 offline benchmark, and remains consistent with values obtained from a current-derivative-based online estimator.
- Open Access
Voltage Synchronization and Proportional Current Sharing of Grid-Forming Inverters
Most previously proposed controllers are analyzed in the small-signal/quasi-steady regime rather than large-signal or transient stability for grid-forming inverters (GFMI). Additionally, methods that presume system-wide data--global measurements and complete grid-model knowledge--are challenging to realize in practice and unsuitable for large-scale operation. Moreover, proportional current sharing is rarely embedded into them. The whole system is a high-order, nonlinear differential system, making analysis intractable without principled simplifications. Hence, contraction stability analysis in GFMI is proposed to guarantee the large-signal stability. Furthermore, a contraction-based controller is proposed to synchronize GFMI. Additionally, this paper proposes integrating an auxiliary virtual-impedance layer into the contraction-based controller to achieve proportional current sharing, while the GFMI retains global stability and voltage synchronization. A dispatchable virtual oscillator control (dVOC), also known as the Andronov--Hopf oscillator (AHO) is used to validate the proposed contraction stability analysis and contraction-based controller with virtual-impedance. It is proved that the complex multi-converter system can achieve output-feedback contraction under large-signal operation. Therefore, without requiring system-wide data, the proposed method offers voltage synchronization, decentralized stability conditions for the transient stability of AHO and proportional current sharing, beyond prior small-signal, quasi-steady analysis.
Open AccessVoltage Synchronization and Proportional Current Sharing of Grid-Forming Inverters
Most previously proposed controllers are analyzed in the small-signal/quasi-steady regime rather than large-signal or transient stability for grid-forming inverters (GFMI). Additionally, methods that presume system-wide data--global measurements and complete grid-model knowledge--are challenging to realize in practice and unsuitable for large-scale operation. Moreover, proportional current sharing is rarely embedded into them. The whole system is a high-order, nonlinear differential system, making analysis intractable without principled simplifications. Hence, contraction stability analysis in GFMI is proposed to guarantee the large-signal stability. Furthermore, a contraction-based controller is proposed to synchronize GFMI. Additionally, this paper proposes integrating an auxiliary virtual-impedance layer into the contraction-based controller to achieve proportional current sharing, while the GFMI retains global stability and voltage synchronization. A dispatchable virtual oscillator control (dVOC), also known as the Andronov--Hopf oscillator (AHO) is used to validate the proposed contraction stability analysis and contraction-based controller with virtual-impedance. It is proved that the complex multi-converter system can achieve output-feedback contraction under large-signal operation. Therefore, without requiring system-wide data, the proposed method offers voltage synchronization, decentralized stability conditions for the transient stability of AHO and proportional current sharing, beyond prior small-signal, quasi-steady analysis.
- 28 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14  (1) , 700-712
A Position-Feedback-Free and Inverter-Nonlinearity-Immune Inductance Estimation Method for PMSM Drives Without Signal Injection
Accurate online maps of the incremental inductances Ld, Lq are critical to model-based drives, sensorless observers, and real-time fault diagnosis. Existing techniques either rely on slow, equipment-intensive offline tests or inject auxiliary signals that disturb the drive, depend on precise rotor position, and are difficult to calibrate against inverter nonlinearities. This paper sidesteps those limitations by recasting the fundamental voltage vector sequence as a differential virtual-voltage-vector that inherently rejects dead-time distortion and device voltage drops. A piece-wise multisample linear regression—applied only to the quasi-linear segment of each current trace—then yields a dead-time-immune, noise-resilient estimate of current slopes. The proposed approach introduces three mutually reinforcing advances: (i) a virtual-voltage-vector-oriented framework that inherently accounts for inverter non-linearities; (ii) a multi-sampling-based current-slope estimation strategy that is immune to dead-time effects and suppresses noise; and (iii) a signal-injection-free, rotor-position-independent inductance observer that is explicitly built on the first two advances, harnessing their accurate voltage modeling and derivative measurements. The proposed estimator is evaluated against the standard AC-standstill test and a current-slope online method, the mean error remains below 5% in every case. Validation spans the full operating range, including extreme load and speed transients.
- 28 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14  (1) , 700-712
A Position-Feedback-Free and Inverter-Nonlinearity-Immune Inductance Estimation Method for PMSM Drives Without Signal Injection
Accurate online maps of the incremental inductances Ld, Lq are critical to model-based drives, sensorless observers, and real-time fault diagnosis. Existing techniques either rely on slow, equipment-intensive offline tests or inject auxiliary signals that disturb the drive, depend on precise rotor position, and are difficult to calibrate against inverter nonlinearities. This paper sidesteps those limitations by recasting the fundamental voltage vector sequence as a differential virtual-voltage-vector that inherently rejects dead-time distortion and device voltage drops. A piece-wise multisample linear regression—applied only to the quasi-linear segment of each current trace—then yields a dead-time-immune, noise-resilient estimate of current slopes. The proposed approach introduces three mutually reinforcing advances: (i) a virtual-voltage-vector-oriented framework that inherently accounts for inverter non-linearities; (ii) a multi-sampling-based current-slope estimation strategy that is immune to dead-time effects and suppresses noise; and (iii) a signal-injection-free, rotor-position-independent inductance observer that is explicitly built on the first two advances, harnessing their accurate voltage modeling and derivative measurements. The proposed estimator is evaluated against the standard AC-standstill test and a current-slope online method, the mean error remains below 5% in every case. Validation spans the full operating range, including extreme load and speed transients.
- 3 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (10) , 14626-14637
Online Estimation of Direct- and Quadrature-Axis Inductances Without Rotational Transformation for Finite Control Set PMSM Drives
Model-based finite control set (FCS) strategies require accurate inductance parameters but encounter challenges in updating these parameters online. To address this issue, a switching time-scale online inductance estimation method is proposed. This method leverages current derivatives and eliminates the need for fundamental inverter voltage, additional signal injection, or rotor position information, making it well-suited for FCS strategies. One key element of the proposed method is the introduction of position scalars, which contain both dc and second-harmonic inductance components. A generalized position scalars (GPSs) calculation method has been developed to ensure compatibility with arbitrary voltage vector sequences. The use of GPSs allows for the separation of the amplitude and phase of the second-harmonic inductance. Building on this separation, the $d$-axis and $q$-axis inductances can be estimated without requiring rotor angle information and rotational transformations. An efficient GPSs table lookup process is designed, reducing the computational burden and facilitating online implementation. Moreover, the proposed method can operate with a zero $d$-axis current and under nonsteady-state conditions without causing rank deficiency issues. Experimental results validate the accuracy and efficacy of the method across the entire operating range.
- 3 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (10) , 14626-14637
Online Estimation of Direct- and Quadrature-Axis Inductances Without Rotational Transformation for Finite Control Set PMSM Drives
Model-based finite control set (FCS) strategies require accurate inductance parameters but encounter challenges in updating these parameters online. To address this issue, a switching time-scale online inductance estimation method is proposed. This method leverages current derivatives and eliminates the need for fundamental inverter voltage, additional signal injection, or rotor position information, making it well-suited for FCS strategies. One key element of the proposed method is the introduction of position scalars, which contain both dc and second-harmonic inductance components. A generalized position scalars (GPSs) calculation method has been developed to ensure compatibility with arbitrary voltage vector sequences. The use of GPSs allows for the separation of the amplitude and phase of the second-harmonic inductance. Building on this separation, the $d$-axis and $q$-axis inductances can be estimated without requiring rotor angle information and rotational transformations. An efficient GPSs table lookup process is designed, reducing the computational burden and facilitating online implementation. Moreover, the proposed method can operate with a zero $d$-axis current and under nonsteady-state conditions without causing rank deficiency issues. Experimental results validate the accuracy and efficacy of the method across the entire operating range.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 12863-12872
Inherent Switching Reallocated CPS-PWM With Improved Voltage Balancing for MMC
Modular multilevel converter is an attractive solution in medium or high voltage applications, and voltage balancing is one of the most significant technical problems especially for CPS-PWM based MMCs. To solve this problem, in this article, an inherent switching reallocated CPS-PWM is proposed for MMC. Based on arm current directions, switching states of submodules (SMs), voltage sorting and carrier sorting results, proposed method divides SMs and carriers into inserting and bypassing groups for each, enabling switching reallocation within these four cooptimized groups to inherently balance capacitor voltages. This effectively prevents additional switchings. Besides, most computations of the proposed CPS-PWM are logical operations implemented in FPGA, so proposed method can achieve reallocation frequency equal to sampling frequency. Unlike other CPS-PWM based methods for voltage balancing, the inherent switching reallocated CPS-PWM not only has superior converge speed in dynamic processes which accommodate a wide power range, but also has excellent balancing accuracy especially considering capacitance differences. Owing to appropriate reallocation principles, the proposed CPS-PWM has lower switching loss compared to existing carrier reallocation methods. Finally, the feasibility and superiority of the proposed method are validated by simulation and experiment results.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 12863-12872
Inherent Switching Reallocated CPS-PWM With Improved Voltage Balancing for MMC
Modular multilevel converter is an attractive solution in medium or high voltage applications, and voltage balancing is one of the most significant technical problems especially for CPS-PWM based MMCs. To solve this problem, in this article, an inherent switching reallocated CPS-PWM is proposed for MMC. Based on arm current directions, switching states of submodules (SMs), voltage sorting and carrier sorting results, proposed method divides SMs and carriers into inserting and bypassing groups for each, enabling switching reallocation within these four cooptimized groups to inherently balance capacitor voltages. This effectively prevents additional switchings. Besides, most computations of the proposed CPS-PWM are logical operations implemented in FPGA, so proposed method can achieve reallocation frequency equal to sampling frequency. Unlike other CPS-PWM based methods for voltage balancing, the inherent switching reallocated CPS-PWM not only has superior converge speed in dynamic processes which accommodate a wide power range, but also has excellent balancing accuracy especially considering capacitance differences. Owing to appropriate reallocation principles, the proposed CPS-PWM has lower switching loss compared to existing carrier reallocation methods. Finally, the feasibility and superiority of the proposed method are validated by simulation and experiment results.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12  (5) , 4691-4702
A Digital FIR-Type Generic Multicell Network Control for LCL-Filtered Grid- Connected Inverters
Active damping is an effective method to suppress the LCL -filter resonance for grid-connected inverters. Generally, the decoupling is employed to achieve the independent regulation of active and reactive power in synchronous dq frame. However, the interactions of active damping and decoupling are commonly neglected when designing current controllers. Besides, for large-power low-switching-frequency applications, the active damping and decoupling performance may be degraded significantly by the digital-control delays and controller discretization. Moreover, the decoupling-damping interaction in digitally-controlled inverters become more complicated than that in analog-controlled ones, which will even trigger instability if the LCL -filter resonance frequency approaches the critical frequency. By analyzing complex-coefficient transfer functions, the influence of these issues on the stability and control performance of grid-connected inverters is revealed in this paper. Further, a finite-impulse-response-type generic multi-cell network control (FIR-GMNC) is proposed based on a precise discrete-domain complex-vector grid-connected inverter model.With the proposed FIR-GMNC, proper control parameters can be quickly and conveniently obtained without iteration in order to optimize the performance of digitally controlled inverters. Finally, a 15-kVA prototype is tested to verify the theoretical analysis and the proposed control.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12  (5) , 4691-4702
A Digital FIR-Type Generic Multicell Network Control for LCL-Filtered Grid- Connected Inverters
Active damping is an effective method to suppress the LCL -filter resonance for grid-connected inverters. Generally, the decoupling is employed to achieve the independent regulation of active and reactive power in synchronous dq frame. However, the interactions of active damping and decoupling are commonly neglected when designing current controllers. Besides, for large-power low-switching-frequency applications, the active damping and decoupling performance may be degraded significantly by the digital-control delays and controller discretization. Moreover, the decoupling-damping interaction in digitally-controlled inverters become more complicated than that in analog-controlled ones, which will even trigger instability if the LCL -filter resonance frequency approaches the critical frequency. By analyzing complex-coefficient transfer functions, the influence of these issues on the stability and control performance of grid-connected inverters is revealed in this paper. Further, a finite-impulse-response-type generic multi-cell network control (FIR-GMNC) is proposed based on a precise discrete-domain complex-vector grid-connected inverter model.With the proposed FIR-GMNC, proper control parameters can be quickly and conveniently obtained without iteration in order to optimize the performance of digitally controlled inverters. Finally, a 15-kVA prototype is tested to verify the theoretical analysis and the proposed control.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39  (5) , 6191-6203
Self-Decoupled Dual Sequence Current Control of D-STATCOM Under Unbalanced Grid Voltage
For the distributed static synchronous compensator (D-STATCOM), the sequence extraction is generally necessary in dual sequence current controls based on double synchronous reference frame (SRF), when the D-STATCOM suffers from unbalanced grid voltage. However, the sequence extraction will narrow down the control bandwidth and increase the control complexity. In this article, the influences of not using sequence extraction on the dual sequence current control are analyzed. On this basis, a self-decoupled dual sequence current control (SDDSCC) is proposed. Accordingly, a novel control parameter design method of SDDSCC is also proposed. The SDDSCC can achieve two types of decoupling. One is the positive and negative sequence current decoupling in double SRF without sequence extraction. The other is the dq current decoupling without specialized dq decoupling method. Due to not using sequence extraction and specialized dq decoupling method, the control bandwidth of the proposed SDDSCC is larger, and the current dynamic response is faster, and the control structure and implementation are simpler. Besides, the control parameter is easily determined by the novel control parameter design method, without multiple iterations of design. Experimental results verify the proposed scheme.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39  (5) , 6191-6203
Self-Decoupled Dual Sequence Current Control of D-STATCOM Under Unbalanced Grid Voltage
For the distributed static synchronous compensator (D-STATCOM), the sequence extraction is generally necessary in dual sequence current controls based on double synchronous reference frame (SRF), when the D-STATCOM suffers from unbalanced grid voltage. However, the sequence extraction will narrow down the control bandwidth and increase the control complexity. In this article, the influences of not using sequence extraction on the dual sequence current control are analyzed. On this basis, a self-decoupled dual sequence current control (SDDSCC) is proposed. Accordingly, a novel control parameter design method of SDDSCC is also proposed. The SDDSCC can achieve two types of decoupling. One is the positive and negative sequence current decoupling in double SRF without sequence extraction. The other is the dq current decoupling without specialized dq decoupling method. Due to not using sequence extraction and specialized dq decoupling method, the control bandwidth of the proposed SDDSCC is larger, and the current dynamic response is faster, and the control structure and implementation are simpler. Besides, the control parameter is easily determined by the novel control parameter design method, without multiple iterations of design. Experimental results verify the proposed scheme.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59  (6) , 6963-6975
Harmonic Disturbance Suppression Based on Precise Shaping of Output Impedance at Selected Frequencies for Standalone Voltage Source Inverter
The output impedance of the voltage source inverter (VSI) would degrade the performance of the VSI when the load is connected. A load current feedforward control is usually used to act as a virtual impedance to reduce the output impedance of the VSI and achieve disturbance suppression. However, due to the variation of the frequency characteristics between the implemented feedforward controller and the theoretical feedforward controller, the output impedance of the VSI cannot be reduced to a lower level, especially the output impedance at harmonic frequencies. In this paper, to improve the performance of harmonic disturbance suppression, the method of precise shaping of output impedance at selected frequencies is proposed for the VSI. By introducing multiple resonant controllers into the load current feedforward control with the consideration of the interaction among the resonant controllers, the variation of the frequency characteristics mentioned above can be compensated accurately at selected frequencies. Then the output impedance of the VSI is further reduced at selected frequencies (including harmonic frequencies), and the performance of the VSI under nonlinear load condition is further improved.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59  (6) , 6963-6975
Harmonic Disturbance Suppression Based on Precise Shaping of Output Impedance at Selected Frequencies for Standalone Voltage Source Inverter
The output impedance of the voltage source inverter (VSI) would degrade the performance of the VSI when the load is connected. A load current feedforward control is usually used to act as a virtual impedance to reduce the output impedance of the VSI and achieve disturbance suppression. However, due to the variation of the frequency characteristics between the implemented feedforward controller and the theoretical feedforward controller, the output impedance of the VSI cannot be reduced to a lower level, especially the output impedance at harmonic frequencies. In this paper, to improve the performance of harmonic disturbance suppression, the method of precise shaping of output impedance at selected frequencies is proposed for the VSI. By introducing multiple resonant controllers into the load current feedforward control with the consideration of the interaction among the resonant controllers, the variation of the frequency characteristics mentioned above can be compensated accurately at selected frequencies. Then the output impedance of the VSI is further reduced at selected frequencies (including harmonic frequencies), and the performance of the VSI under nonlinear load condition is further improved.