A Prospective, Multicentre Case-Control Trial Examining Factors That Explain Variable Clinical Performance in Post Lingual Adult CI Recipients
Open Access
- 27 June 2025
- journal article
- research article
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Abstract
This study investigated which of a range of factors could explain performance in two distinct groups of experienced, adult cochlear implant recipients differentiated by performance on words in quiet: 72 with poorer word scores versus 77 with better word scores. Tests measured the potential contribution of sound processor mapping, electrode placement, neural health, impedance, cognitive, and patient-related factors in predicting performance. A systematically measured sound processor MAP was compared to the subject's walk-in MAP. Electrode placement included modiolar distance, basal and apical insertion angle, and presence of scalar translocation. Neural health measurements included bipolar thresholds, polarity effect using asymmetrical pulses, and evoked compound action potential (ECAP) measures such as the interphase gap (IPG) effect, total refractory time, and panoramic ECAP. Impedance measurements included trans impedance matrix and four-point impedance. Cognitive tests comprised vocabulary ability, the Stroop test, and the Symbol Digits Modality Test. Performance was measured with words in quiet and sentence in noise tests and basic auditory sensitivity measures including phoneme discrimination in noise and quiet, amplitude modulation detection thresholds and quick spectral modulation detection. A range of predictor variables accounted for between 33% and 60% of the variability in performance outcomes. Multivariable regression analyses showed four key factors that were consistently predictive of poorer performance across several outcomes: substantially underfitted sound processor MAP thresholds, higher average bipolar thresholds, greater total refractory time, and greater IPG offset. Scalar translocation, cognitive variables, and other patient related factors were also significant predictors across more than one performance outcome.Keywords
This publication has 64 references indexed in Scilit:
- Electrode array design determines scalar position, dislocation rate and angle and postoperative speech perceptionEuropean Archives of Oto-Rhino-Laryngology, 2021
- Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2020
- A Site-Selection Strategy Based on Polarity Sensitivity for Cochlear Implants: Effects on Spectro-Temporal Resolution and Speech PerceptionJournal of the Association for Research in Otolaryngology, 2019
- Effect of Stimulus Polarity on Detection Thresholds in Cochlear Implant Users: Relationships with Average Threshold, Gap Detection, and Rate DiscriminationJournal of the Association for Research in Otolaryngology, 2018
- Verbal working memory and inhibition‐concentration in adults with cochlear implantsLaryngoscope Investigative Otolaryngology, 2017
- Effect of Pulse Polarity on Thresholds and on Non-monotonic Loudness Growth in Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2017
- Systematic review of compound action potentials as predictors for cochlear implant performanceThe Laryngoscope, 2016
- Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral ThresholdsJournal of the Association for Research in Otolaryngology, 2016
- Examining the Electro-Neural Interface of Cochlear Implant Users Using Psychophysics, CT Scans, and Speech UnderstandingJournal of the Association for Research in Otolaryngology, 2014
- Auditory-Nerve Responses to Varied Inter-Phase Gap and Phase Duration of the Electric Pulse Stimulus as Predictors for Neuronal DegenerationJournal of the Association for Research in Otolaryngology, 2014