Validation of three-dimensional thoracic electrical impedance tomography of horses during normal and increased tidal volumes
Open Access
- 1 March 2024
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (3) , 035010
Abstract
Objective . Data from two-plane electrical impedance tomography (EIT) can be reconstructed into various slices of functional lung images, allowing for more complete visualisation and assessment of lung physiology in health and disease. The aim of this study was to confirm the ability of 3D EIT to visualise normal lung anatomy and physiology at rest and during increased ventilation (represented by rebreathing). Approach . Two-plane EIT data, using two electrode planes 20 cm apart, were collected in 20 standing sedate horses at baseline (resting) conditions, and during rebreathing. EIT data were reconstructed into 3D EIT whereby tidal impedance variation (TIV), ventilated area, and right-left and ventral-dorsal centres of ventilation (CoV RL and CoV VD , respectively) were calculated in cranial, middle and caudal slices of lung, from data collected using the two planes of electrodes. Main results . There was a significant interaction of time and slice for TIV ( p < 0.0001) with TIV increasing during rebreathing in both caudal and middle slices. The ratio of right to left ventilated area was higher in the cranial slice, in comparison to the caudal slice ( p = 0.0002). There were significant effects of time and slice on CoV VD whereby the cranial slice was more ventrally distributed than the caudal slice ( p < 0.0009 for the interaction). Significance . The distribution of ventilation in the three slices corresponds with topographical anatomy of the equine lung. This study confirms that 3D EIT can accurately represent lung anatomy and changes in ventilation distribution during rebreathing in standing sedate horses.Keywords
This publication has 30 references indexed in Scilit:
- Evaluation of histamine‐provoked changes in airflow using electrical impedance tomography in horsesEquine Veterinary Journal, 2019
- Thoracic EIT in 3D: experiences and recommendationsPhysiological Measurement, 2019
- Monitoring of tidal ventilation by electrical impedance tomography in anaesthetised horsesEquine Veterinary Journal, 2018
- Regional ventilation distribution and dead space in anaesthetized horses treated with and without continuous positive airway pressure: novel insights by electrical impedance tomography and volumetric capnographyVeterinary Anaesthesia and Analgesia, 2018
- Assessment of distribution of ventilation and regional lung compliance by electrical impedance tomography in anaesthetized horses undergoing alveolar recruitment manoeuvresVeterinary Anaesthesia and Analgesia, 2017
- Assessment of distribution of ventilation by electrical impedance tomography in standing horsesPhysiological Measurement, 2015
- Distribution of ventilation in pregnant Shetland ponies measured by Electrical Impedance TomographyRespiratory Physiology & Neurobiology, 2012
- Characterization of normal tidal breathing flow-volume loops for Thoroughbred horsesVeterinary Research Communications, 1995
- Studies on the effect of the third dimension on a two-dimensional electrical impedance tomography systemClinical Physics and Physiological Measurement, 1991
- Relationship between condition score, physical measurements and body fat percentage in maresEquine Veterinary Journal, 1983