Evaluation of histamine‐provoked changes in airflow using electrical impedance tomography in horses
- 2 December 2019
- journal article
- research article
- Published by Wiley in Equine Veterinary Journal
- Vol. 52 (4) , 556-563
Abstract
Background: Electrical impedance tomography (EIT) generates thoracic impedance images of the lungs and has been used to assess ventilation in horses. This technique may have application in the detection of changes in airflow associated with equine asthma. Objectives: The objective was to determine if histamine‐induced airflow changes observed with flowmetric plethysmography (Δflow) could also be explained using global and regional respiratory gas flow signals calculated from EIT signals. Study design: Experimental in vivo study. Methods: Six horses, sedated using detomidine were fitted with a thoracic EIT belt and flowmetric plethysmography hardware. Saline (baseline = BL) and increasing concentrations of histamine (C1‐4) were nebulised into the face mask until a change in breathing pattern was clinically confirmed and Δflow increased greater or equal to 50%. After nebulisation Δflow and EIT images were recorded over 3 minutes and peak global inspiratory (InF global ) and expiratory (ExF global ) flow as well as peak regional expiratory and inspiratory flow for the dorsal and the ventral area of the right and left lungs were evaluated. Delta flow, InF global and ExF global at subsequent concentrations were indexed to baseline (y i = C i /BL−1). Indexed and nonindexed variables were evaluated for a difference from baseline at sequential histamine doses (time). Multiple linear regression assessment of variance in delta flow was also investigated. Results: Consistent with histamine‐provoked increases in Δflow, the global flow indices increased significantly. A significant increase in regional inspiratory flow was seen in the right and left ventral lung and dorsal right lung. Multiple regression revealed that the variance in ExF global , and right and left ventral expiratory flow best explained the variance in Δflow ( r 2 = .82). Main limitations: Low number of horses and horses were healthy. Conclusions: Standardised changes in airflow during histamine challenge could be detected using EIT gas flow variables.Keywords
This publication has 26 references indexed in Scilit:
- Monitoring of tidal ventilation by electrical impedance tomography in anaesthetised horsesEquine Veterinary Journal, 2018
- Flow‐volume loops measured with electrical impedance tomography in pediatric patients with asthmaPediatric Pulmonology, 2018
- Regional ventilation distribution and dead space in anaesthetized horses treated with and without continuous positive airway pressure: novel insights by electrical impedance tomography and volumetric capnographyVeterinary Anaesthesia and Analgesia, 2018
- Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General AnaesthesiaPLOS ONE, 2016
- Inflammatory Airway Disease of Horses—Revised Consensus StatementJournal of Veterinary Internal Medicine, 2016
- Assessment of distribution of ventilation by electrical impedance tomography in standing horsesPhysiological Measurement, 2015
- Determination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilationBMC Pulmonary Medicine, 2014
- Real-time detection of pneumothorax using electrical impedance tomography*Critical Care Medicine, 2008
- Flowmetric comparison of respiratory inductance plethysmography and pneumotachography in horses.Journal of Applied Physiology, 2001
- Relationship between condition score, physical measurements and body fat percentage in maresEquine Veterinary Journal, 1983