CSCristy Secombe

Cristy Secombe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cristy Secombe has a total of 79 co-authors. Here are the top co-authors by number of shared publications:

  • David Byrne

    School of Veterinary Medicine Murdoch University Perth Western Australia Australia

    7 shared publications
  • Andy Adler

    Department of Systems and Computer Engineering Carleton University Ottawa Ontario Canada

    3 shared publications
  • Giselle Hosgood

    Department of Small Animal Surgery, College of Veterinary Medicine, School of Veterinary and Life sciences, Murdoch University Veterinary Hospital, Murdoch, Australia

    3 shared publications
  • Martina Mosing

    Anaesthesiology and Intensive Care, Clinical Centre of Small Animal Health and Research Clinical Department for Small Animals and Horses, University of Veterinary Medicine Vienna Austria

    3 shared publications
  • Martina Mosing

    Anaesthesiology and Intensive Care, Clinical Centre for Small Animal Health and Research, Clinical Department for Small Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Austria

    3 shared publications
  • Andy Adler

    Carleton University

    2 shared publications

Latest Publications

  • Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses

    by Nicole Studer, David Byrne, Anthea Raisis, Andy Adler, Jesslyn Cheong, Cristy Secombe, Johannes Peter Schramel, Martina Mosing

    Background: Traditional one‐plane (oneP) electrical impedance tomography (EIT) electrode configurations limit evaluation to a convex lens‐shaped lung slice, prone to overrepresentation of central areas. Two‐plane (twoP) EIT is expected to refine this technique and result in more representative lung imaging. Objectives: To compare ventilation distribution using single slice reconstructions, obtained with twoP or oneP. Study Design: Computational modelling and in vivo exploratory randomised experimental trial. Methods: A finite element simulation model of oneP and twoP was calculated to estimate captured lung fields. Thereafter, twoP and oneP EIT data were collected in 20 standing horses at baseline, during stance variations and rebreathing. A visual functional region of interest representing the lung field was defined and EIT data reconstructed. Centres of ventilation (CoV), regional ventilation (∆Z, expressed as L or R for left or right lung, and D, CD, CV, or V for dorsal, central dorsal, central ventral or ventral regions) and tidal impedance variation (TIV) were compared between configurations at baseline and between baseline and challenge measurements using Wilcoxon matched pairs signed rank test and a mixed effect model. Proportional changes were compared using a paired t ‐test. Results: The simulation revealed a more evenly distributed vertical sensitivity with twoP compared to oneP. In vivo data were analysed to determine which EIT regional parameters increased (twoP vs. oneP). At baseline, ∆ZL D , ∆ZR D and CoV VD , were higher when using twoP (7.1 (5.9–8.0) vs. 2.2 (0.9–3.5): p < 0.001; 6.4 (5.6–7.5) vs. 1.5 (0.5–2.79): p < 0.001; 47.7 (46.8–49.29) vs. 43.3 (42.2–45.8): p < 0.001). With rebreathing, an increase in TIV and CoV VD was seen with both belt configurations (oneP: 25.13 (±1.967) vs. 49.39 (±11.27): p < 0.001 and 44.3 (±2.300) vs. 45.64 (±2.243): p = 0.002; twoP: 20.21 (±7.398) vs. 49.6 (±13.09): p < 0.001 and 48.79 (±2.126) vs. 50.38 (±1.783): p = 0.005). Conclusions: TwoP EIT reconstructions resulted in a more vertically uniform representation of ventilation in simulation and in vivo. This likely results in an enhanced representation of peripheral lung fields.

  • Open Access

    Generation of equine‐specific local antibiograms: reproductive tract of mares and fillies in Western Australia

    by Jkh Hoong, C Boyd, C Secombe, D Byrne

    Introduction: Antimicrobial resistance (AMR) may lead to increasing inefficacy and treatment failure of bacterial infections in the future. Antimicrobial stewardship (AMS) programmes are critical to ensuring the continued efficacy of available antimicrobials. There is a lack of published evidence‐based data on the susceptibility of isolates from common reproductive infections encountered in mares. This study aims to provide equine veterinarians in Western Australia (WA) with the most appropriate first‐line empirical antimicrobials for infections of the mare reproductive tract. Materials and methods: A retrospective study was conducted on reproductive tract swab/fluid culture and sensitivity results of mares and fillies in WA from July 2015 to June 2020. An algorithm was generated using R to create an antibiogram for the mare reproductive system. Results: The antibiogram included 767 reproductive tract isolates. Escherichia coli ( E. coli ) (277 of 767; 36%) was the most commonly isolated, followed by Streptococcus (240 of 767; 31%). Gram‐negative isolates were most susceptible to enrofloxacin (84%), followed by ceftiofur (75%), gentamicin (72%) and tetracycline (65%). Gram‐positive isolates were most susceptible to ampicillin (86%), followed by penicillin (83%), ceftiofur (83%) and trimethoprim‐sulfonamide (TMS, 76%). The overall susceptibility of ceftiofur decreased across both Gram‐negative and Gram‐positive isolates during the time periods 2015–2017 and 2018–2020 from 79% to 69% and 91% to 75%, respectively. Discussion: Gram‐negative isolates were most susceptible to the high importance antimicrobials ceftiofur and enrofloxacin. However, these antimicrobials should be used judiciously only after culture and sensitivity testing have been performed, in accordance with the Australian Veterinary Prescribing Guidelines, as part of AMS. This study found that Gram‐negative organisms are most susceptible to first‐line empirical treatment with tetracycline if E. coli is suspected, or gentamicin when in doubt. Gram‐positive isolates were most susceptible to first‐line empirical treatment with ampicillin, penicillin or TMS. Regular updates to the antibiogram are required to provide contemporary empirical guidance for the use of antimicrobials.

  • Open Access

    Validation of three-dimensional thoracic electrical impedance tomography of horses during normal and increased tidal volumes

    by David P Byrne, Nicole Studer, Cristy Secombe, Alexander Cieslewicz, Giselle Hosgood, Anthea Raisis, Andy Adler, Martina Mosing

    Objective . Data from two-plane electrical impedance tomography (EIT) can be reconstructed into various slices of functional lung images, allowing for more complete visualisation and assessment of lung physiology in health and disease. The aim of this study was to confirm the ability of 3D EIT to visualise normal lung anatomy and physiology at rest and during increased ventilation (represented by rebreathing). Approach . Two-plane EIT data, using two electrode planes 20 cm apart, were collected in 20 standing sedate horses at baseline (resting) conditions, and during rebreathing. EIT data were reconstructed into 3D EIT whereby tidal impedance variation (TIV), ventilated area, and right-left and ventral-dorsal centres of ventilation (CoV RL and CoV VD , respectively) were calculated in cranial, middle and caudal slices of lung, from data collected using the two planes of electrodes. Main results . There was a significant interaction of time and slice for TIV ( p < 0.0001) with TIV increasing during rebreathing in both caudal and middle slices. The ratio of right to left ventilated area was higher in the cranial slice, in comparison to the caudal slice ( p = 0.0002). There were significant effects of time and slice on CoV VD whereby the cranial slice was more ventrally distributed than the caudal slice ( p < 0.0009 for the interaction). Significance . The distribution of ventilation in the three slices corresponds with topographical anatomy of the equine lung. This study confirms that 3D EIT can accurately represent lung anatomy and changes in ventilation distribution during rebreathing in standing sedate horses.


  • Open Access

    Declining engagement of veterinary services in Australian animal production systems: why has this occurred and what are the risks?

    by Cj Secombe

    The provision of veterinary services is essential to deliver animal health and welfare outcomes, but over the last several decades demand for veterinary services in animal production systems has broadly declined in Australia. Reduced demand is closely related to a decline in the size of the production animal veterinary workforce, and there is evidence that the percentage of veterinarians participating in the delivery of veterinary services to animal production systems has lessened. Reduced demand for veterinary services in the production animal sector is likely to be attributed to several factors, including challenges around widespread adoption of preventive veterinary services, improved self-efficacy of producers through advancement of knowledge, and potential concern by producers over the role of veterinarians in production animal systems. Declining veterinary engagement results in increased risk at both the individual farm level (diminished expertise to deliver reactive and proactive veterinary services) and at a population level (increased biosecurity risk and risk to social licence to operate). The current environment and the community trust in the profession should be seen as an opportunity to develop and implement a strategy to halt and reverse the decline in demand for production animal veterinary services. Such a strategy will require significant and sustained collaboration between the veterinary profession, Industry and government.


  • Open Access

    The prevalence and changes over time of equine glandular gastric disease in a teaching herd population

    by Kirsten P. Sharbine, Emma J. McConnell, Cristy Secombe, David Byrne

    Summary: Background: The natural progression of equine glandular gastric disease (EGGD) in the absence of treatment has not yet been described in the literature, nor has the prevalence in a teaching herd population been reported. Objectives: The aims of this study were to determine the prevalence of disease in a teaching population over the study period (2019–2021) and to observe the changes over time in disease severity of naturally occurring diseases (not experimentally induced) without medical intervention. Methods: Twenty‐one horses underwent an initial gastroscopy and a repeat gastroscopy between 14 and 731 days later. Gastroscopy data were graded quantitatively and described qualitatively. Prevalence and 95% confidence intervals (CI) were calculated. The changes over time were determined by comparing initial and repeat gastroscopies. Results: The prevalence from initial, repeat and total number of gastroscopies was 62% (95% CI: 40.8–79.3), 71% (95% CI: 50.0–86.2) and 67% (95% CI: 51.6–79), respectively. The changes over time included worsening of disease in 29% of horses (95% CI: 13.8–50.0), improvement of disease to a lower grade in 24% (95% CI: 10.6–45.1), no change in grade in 38% (95% CI: 20.8–59.1), and complete resolution of disease to grade 0 in 10% (95% CI: 2.7–28.9). Main limitations: Limitations included a maximum of two gastroscopies per horse given COVID‐19 restrictions on data collection, and highly varied interval times between initial and repeat gastroscopies. Conclusion: In conclusion, there is a high prevalence of disease in this teaching herd. The changes over time in naturally occurring diseases without medical intervention might include worsening, improvement, no change or resolution of disease.


  • Open Access

    Electrical impedance tomography to measure lung ventilation distribution in healthy horses and horses with left-sided cardiac volume overload

    by Muriel Sacks, David P. Byrne, Nicolas Herteman, Cristy Secombe, Andy Adler, Giselle Hosgood, Anthea L. Raisis, Martina Mosing

    Background Left-sided cardiac volume overload (LCVO) can cause fluid accumulation in lung tissue changing the distribution of ventilation, which can be evaluated by electrical impedance tomography (EIT). Objectives To describe and compare EIT variables in horses with naturally occurring compensated and decompensated LCVO and compare them to a healthy cohort. Animals Fourteen adult horses, including university teaching horses and clinical cases (healthy: 8; LCVO: 4 compensated, 2 decompensated). Methods In this prospective cohort study, EIT was used in standing, unsedated horses and analyzed for conventional variables, ventilated right (VAR) and left (VAL) lung area, linear-plane distribution variables (avg-max VΔZLine, VΔZLine), global peak flows, inhomogeneity factor, and estimated tidal volume. Horses with decompensated LCVO were assessed before and after administration of furosemide. Variables for healthy and LCVO-affected horses were compared using a Mann-Whitney test or unpaired t-test and observations from compensated and decompensated horses are reported. Results Compared to the healthy horses, the LCVO cohort had significantly less VAL (mean difference 3.02; 95% confidence interval .77-5.2; P = .02), more VAR (−1.13; −2.18 to −.08; P = .04), smaller avg-max VΔZLLine (2.54; 1.07-4.00; P = .003) and VΔZLLine (median difference 5.40; 1.71-9.09; P = .01). Observation of EIT alterations were reflected by clinical signs in horses with decompensated LCVO and after administration of furosemide. Conclusions and Clinical Importance EIT measurements of ventilation distribution showed less ventilation in the left lung of horses with LCVO and might be useful as an objective assessment of the ventilation effects of cardiogenic pulmonary disease in horses.


  • Open Access

    Novel Hendra virus variant detected by sentinel surveillance of Australian horses

    by Edward J. Annand, Bethany A. Horsburgh, Kai Xu, Peter A. Reid, Ben Poole, Maximillian C. de Kantzow, Nicole Brown, Alison Tweedie, Michelle Michie, John D. Grewar, et al.

    A novel Hendra virus (HeV) variant, not detected by routine testing, was identified and isolated from a Queensland horse that suffered acute, fatal disease consistent with HeV infection. Whole genome sequencing and phylogenetic analysis demonstrated the variant to have ~83% nucleotide identity to the prototype HeV strain. An updated RT-qPCR assay was designed for routine HeV surveillance. In silico and in vitro comparison of the receptor-binding protein with prototypic HeV showed that the human monoclonal antibody m102.4 used for post-exposure prophylaxis, as well as the current equine vaccine, should be effective against this variant. Genetic similarity of this virus to sequences detected from grey-headed flying-foxes suggests the variant circulates at-least in this species. Studies determining infection kinetics, pathogenicity, reservoir-species associations, viral–host co-evolution and spillover dynamics for this virus are urgently needed. Surveillance and biosecurity practices should be updated to appreciate HeV spillover risk across all regions frequented by flying foxes.


  • The use of electrical impedance tomography (EIT) to evaluate pulse rate in anaesthetised horses

    by A.L. Raisis, M. Mosing, G.L. Hosgood, C.J. Secombe, A. Adler, A.D. Waldmann


  • Open Access

    Can bronchoconstriction and bronchodilatation in horses be detected using electrical impedance tomography?

    by Cristy Secombe, Andy Adler, Giselle Hosgood, Anthea Raisis, Martina Mosing

    Background Electrical impedance tomography (EIT) generates images of the lungs based on impedance change and was able to detect changes in airflow after histamine challenge in horses. Objectives To confirm that EIT can detect histamine‐provoked changes in airflow and subsequent drug‐induced bronchodilatation. Novel EIT flow variables were developed and examined for changes in airflow. Methods Bronchoconstriction was induced using stepwise histamine bronchoprovocation in 17 healthy sedated horses. The EIT variables were recorded at baseline, after saline nebulization (control), at the histamine concentration causing bronchoconstriction (Cmax) and 2 and 10 minutes after albuterol (salbutamol) administration. Peak global inspiratory (PIFEIT) and peak expiratory EIT (PEFEIT) flow, slope of the global expiratory flow‐volume curve (FVslope), steepest FVslope over all pixels in the lung field, total impedance change (surrogate for tidal volume; VTEIT) and intercept on the expiratory FV curve normalized to VTEIT (FVintercept/VTEIT) were indexed to baseline and analyzed for a difference from the control, at Cmax, 2 and 10 minutes after albuterol. Multiple linear regression explored the explanation of the variance of Δflow, a validated variable to evaluate bronchoconstriction using all EIT variables. Results At Cmax, PIFEIT, PEFEIT, and FVslope significantly increased whereas FVintercept/VT decreased. All variables returned to baseline 10 minutes after albuterol. The VTEIT did not change. Multivariable investigation suggested 51% of Δflow variance was explained by a combination of PIFEIT and PEFEIT. Conclusions and Clinical Importance Changes in airflow during histamine challenge and subsequent albuterol administration could be detected by various EIT flow volume variables.


  • Evaluation of histamine‐provoked changes in airflow using electrical impedance tomography in horses

    by Cristy Secombe, Andreas D. Waldmann, Giselle Hosgood, Martina Mosing

    Background: Electrical impedance tomography (EIT) generates thoracic impedance images of the lungs and has been used to assess ventilation in horses. This technique may have application in the detection of changes in airflow associated with equine asthma. Objectives: The objective was to determine if histamine‐induced airflow changes observed with flowmetric plethysmography (Δflow) could also be explained using global and regional respiratory gas flow signals calculated from EIT signals. Study design: Experimental in vivo study. Methods: Six horses, sedated using detomidine were fitted with a thoracic EIT belt and flowmetric plethysmography hardware. Saline (baseline = BL) and increasing concentrations of histamine (C1‐4) were nebulised into the face mask until a change in breathing pattern was clinically confirmed and Δflow increased greater or equal to 50%. After nebulisation Δflow and EIT images were recorded over 3 minutes and peak global inspiratory (InF global ) and expiratory (ExF global ) flow as well as peak regional expiratory and inspiratory flow for the dorsal and the ventral area of the right and left lungs were evaluated. Delta flow, InF global and ExF global at subsequent concentrations were indexed to baseline (y i = C i /BL−1). Indexed and nonindexed variables were evaluated for a difference from baseline at sequential histamine doses (time). Multiple linear regression assessment of variance in delta flow was also investigated. Results: Consistent with histamine‐provoked increases in Δflow, the global flow indices increased significantly. A significant increase in regional inspiratory flow was seen in the right and left ventral lung and dorsal right lung. Multiple regression revealed that the variance in ExF global , and right and left ventral expiratory flow best explained the variance in Δflow ( r 2 = .82). Main limitations: Low number of horses and horses were healthy. Conclusions: Standardised changes in airflow during histamine challenge could be detected using EIT gas flow variables.