Injury Risk Functions for the Midsized Male Wrist and Elbow as a Result of Behind Shield Blunt Trauma
- 13 May 2024
- journal article
- research article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-29
Abstract
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield deflecting or absorbing a projectile and deforming toward the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user. Two vulnerable locations along the upper extremity were investigated—the wrist and elbow—on eight postmortem human subjects (PMHS) using a pneumatic impacting apparatus for investigating the fracture threshold as a result of behind shield blunt trauma (BSBT). Impacting parameters were established by subjecting an augmented WorldSID anthropomorphic test device (ATD) positioned behind a ballistic shield to ballistic impacts. These data were used to form the impact parameters applied to PMHS, where the wrist most frequently fractured at the distal radius and the elbow most frequently fractured at the radial head. The fracture threshold for the wrist was 5663±1386 N (mean±standard deviation), higher than the elbow at 4765±894 N (though not significantly, p = 0.15). The failure impact velocity for wrist impacts was 17.7±2.1 m/s, while for the elbow, the failure impact velocity was 19.5±0.9 m/s. An approximate 10% risk of fracture threshold was identified on the modified WorldSID ATD (no flesh analogue included) to inform future protective standards.Keywords
This publication has 17 references indexed in Scilit:
- Effects of input energy and impactor shape on cranial fracture patternsForensic Science International, 2023
- Behind Shield Blunt Trauma: Characterizing the Back-Face Deformation of Shields with a Focus on Upper Limb LoadingAnnals of Biomedical Engineering, 2023
- Injury risk of interphalangeal and metacarpophalangeal joints under impact loadingJournal of the Mechanical Behavior of Biomedical Materials, 2019
- The effect of impact duration on the axial fracture tolerance of the isolated tibia during automotive and military impactsJournal of the Mechanical Behavior of Biomedical Materials, 2018
- The effect of static muscle forces on the fracture strength of the intact distal radius in vitro in response to simulated forward fall impactsJournal of Biomechanics, 2014
- Human surrogates for injury biomechanics researchClinical Anatomy, 2011
- Adequacy of laboratory simulation of in-line skater fallsThe Journal of Hand Surgery, 2005
- Injury risk function for the small female wrist in axial loadingAccident Analysis & Prevention, 2003
- The mechanisms of elbow fractures: an investigation using impact tests in vitroInjury, 1995
- Cortical and trabecular bone contribute strength to the osteopenic distal radiusJournal of Orthopaedic Research, 1994