Julia E. de Lange
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Julia E. de Lange has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cheryl E. Quenneville
School of Biomedical Engineering, McMaster University, Hamilton, Canada
4 shared publications Aryen Shakib
School of Biomedical Engineering, McMaster University, 1280 Main Street , West Hamilton, ON L8S 4L8, Canada
1 shared publicationCarson Brewer
Department of Mechanical Engineering, McMaster University, 1280 Main Street , West Hamilton, ON L8S 4L8, Canada
1 shared publication- Ishan Acharya
Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada
1 shared publication - John T. Van Tuyl
Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada
1 shared publication - Lori L. Burrows
School of Biomedical Engineering, McMaster University , Hamilton, ON L8S 4L8, Canada
1 shared publication
Latest Publications
- 13 May 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-29
Injury Risk Functions for the Midsized Male Wrist and Elbow as a Result of Behind Shield Blunt Trauma
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield deflecting or absorbing a projectile and deforming toward the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user. Two vulnerable locations along the upper extremity were investigated—the wrist and elbow—on eight postmortem human subjects (PMHS) using a pneumatic impacting apparatus for investigating the fracture threshold as a result of behind shield blunt trauma (BSBT). Impacting parameters were established by subjecting an augmented WorldSID anthropomorphic test device (ATD) positioned behind a ballistic shield to ballistic impacts. These data were used to form the impact parameters applied to PMHS, where the wrist most frequently fractured at the distal radius and the elbow most frequently fractured at the radial head. The fracture threshold for the wrist was 5663±1386 N (mean±standard deviation), higher than the elbow at 4765±894 N (though not significantly, p = 0.15). The failure impact velocity for wrist impacts was 17.7±2.1 m/s, while for the elbow, the failure impact velocity was 19.5±0.9 m/s. An approximate 10% risk of fracture threshold was identified on the modified WorldSID ATD (no flesh analogue included) to inform future protective standards.
- 13 May 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-29
Injury Risk Functions for the Midsized Male Wrist and Elbow as a Result of Behind Shield Blunt Trauma
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield deflecting or absorbing a projectile and deforming toward the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user. Two vulnerable locations along the upper extremity were investigated—the wrist and elbow—on eight postmortem human subjects (PMHS) using a pneumatic impacting apparatus for investigating the fracture threshold as a result of behind shield blunt trauma (BSBT). Impacting parameters were established by subjecting an augmented WorldSID anthropomorphic test device (ATD) positioned behind a ballistic shield to ballistic impacts. These data were used to form the impact parameters applied to PMHS, where the wrist most frequently fractured at the distal radius and the elbow most frequently fractured at the radial head. The fracture threshold for the wrist was 5663±1386 N (mean±standard deviation), higher than the elbow at 4765±894 N (though not significantly, p = 0.15). The failure impact velocity for wrist impacts was 17.7±2.1 m/s, while for the elbow, the failure impact velocity was 19.5±0.9 m/s. An approximate 10% risk of fracture threshold was identified on the modified WorldSID ATD (no flesh analogue included) to inform future protective standards.
- 8 April 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (9) , 1-35
Estimation of Injury Limits at Vulnerable Impact Locations Along the Forearm Via THUMS AM50 Finite Element Model at Airbag Loading Rates
Side and frontal airbag deployment represents the main injury mechanism to the upper extremity during automotive collisions. Previous dynamic injury limit research has been limited to testing the forearm at either the assumed most vulnerable location to fracture, the distal 1/3rd, or the midpoint. Studies have varied the surface to which impacts were applied, with no clear consensus on the site of greatest vulnerability. The unpredictability of airbag impact location, especially with altered hand positioning, limits the effectiveness of existing forearm injury limits determined from impacts at only one location. The current study quantified the effect of impacts at alternative locations on injury risk along the forearm using the THUMS FE model. Airbag-level impacts were simulated along the forearm on all four anatomical surfaces. Results showed the distal 1/3rd is not the most vulnerable location (for any side), indicating forearm fracture is not solely driven by area moment of inertia (as previously assumed). The posterior forearm was the weakest, suggesting that current test standards underestimate the fracture risk of the forearm. Linear regression models showed strong correlation between forearm fracture risk and bone geometry (cross-sectional area and area moment of inertia) as well as soft-tissue depth, potentially providing the ability to predict forearm injury tolerances for any location or forearm size. This study demonstrated the forearm's vulnerability to fracture from airbag deployments, indicating the need for safety systems to better address injury mechanisms for the upper limb to effectively protect drivers.
- 8 April 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (9) , 1-35
Estimation of Injury Limits at Vulnerable Impact Locations Along the Forearm Via THUMS AM50 Finite Element Model at Airbag Loading Rates
Side and frontal airbag deployment represents the main injury mechanism to the upper extremity during automotive collisions. Previous dynamic injury limit research has been limited to testing the forearm at either the assumed most vulnerable location to fracture, the distal 1/3rd, or the midpoint. Studies have varied the surface to which impacts were applied, with no clear consensus on the site of greatest vulnerability. The unpredictability of airbag impact location, especially with altered hand positioning, limits the effectiveness of existing forearm injury limits determined from impacts at only one location. The current study quantified the effect of impacts at alternative locations on injury risk along the forearm using the THUMS FE model. Airbag-level impacts were simulated along the forearm on all four anatomical surfaces. Results showed the distal 1/3rd is not the most vulnerable location (for any side), indicating forearm fracture is not solely driven by area moment of inertia (as previously assumed). The posterior forearm was the weakest, suggesting that current test standards underestimate the fracture risk of the forearm. Linear regression models showed strong correlation between forearm fracture risk and bone geometry (cross-sectional area and area moment of inertia) as well as soft-tissue depth, potentially providing the ability to predict forearm injury tolerances for any location or forearm size. This study demonstrated the forearm's vulnerability to fracture from airbag deployments, indicating the need for safety systems to better address injury mechanisms for the upper limb to effectively protect drivers.
- 1 September 2021
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 144 (1)
The Axial Impact Response and Plantar Load Distribution of the Hybrid III and Military Lower Extremity Under Altered Ankle Postures
Foot injuries as a result of automotive collisions are frequent and impactful. Anthropomorphic test devices (ATDs), used to assess injury risk during impact scenarios such as motor vehicle collisions, typically assess risk of foot/ankle injuries by analyzing data in tibia load cells. The peak axial force and the tibia index are metrics commonly used to evaluate risk of injury to the lower extremity but do not directly account for injury risk to the foot, or the risk of injury associated with out-of-position loading. Two ATDs, the Hybrid III lower leg and the Military Lower Extremity, were exposed to axial impacts at seven different ankle postures. An array of piezoresistive sensors located on the insole of a boot was employed during these tests to assess the load distribution variations among postures and between ATD models on the plantar surface of the foot. Both posture and ATD model affected the load distribution on the foot, highlighting the need for regional injury risk assessments in this vulnerable anatomical region. The increase in forefoot loading during plantarflexion was not reflected in the standard industry metrics of peak axial force or tibia index, suggesting that increased fracture risk to the forefoot would not be detected. The variations in load distribution between the models could also alter injury risk assessment in frontal collisions based on differences in attenuation. These data could be used for regional foot injury assessment and to inform the design of an improved ATD foot.
- 1 September 2021
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 144 (1)
The Axial Impact Response and Plantar Load Distribution of the Hybrid III and Military Lower Extremity Under Altered Ankle Postures
Foot injuries as a result of automotive collisions are frequent and impactful. Anthropomorphic test devices (ATDs), used to assess injury risk during impact scenarios such as motor vehicle collisions, typically assess risk of foot/ankle injuries by analyzing data in tibia load cells. The peak axial force and the tibia index are metrics commonly used to evaluate risk of injury to the lower extremity but do not directly account for injury risk to the foot, or the risk of injury associated with out-of-position loading. Two ATDs, the Hybrid III lower leg and the Military Lower Extremity, were exposed to axial impacts at seven different ankle postures. An array of piezoresistive sensors located on the insole of a boot was employed during these tests to assess the load distribution variations among postures and between ATD models on the plantar surface of the foot. Both posture and ATD model affected the load distribution on the foot, highlighting the need for regional injury risk assessments in this vulnerable anatomical region. The increase in forefoot loading during plantarflexion was not reflected in the standard industry metrics of peak axial force or tibia index, suggesting that increased fracture risk to the forefoot would not be detected. The variations in load distribution between the models could also alter injury risk assessment in frontal collisions based on differences in attenuation. These data could be used for regional foot injury assessment and to inform the design of an improved ATD foot.
- 29 November 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 141 (2)
A Force-Sensing Insole to Quantify Impact Loading to the Foot
Lower leg injuries commonly occur in frontal automobile collisions, and are associated with high disability rates. Accurate methods to predict these injuries must be developed to facilitate the testing and improvement of vehicle safety systems. Anthropomorphic test devices (ATDs) are often used to assess injury risk by mimicking the behavior of the human body in a crash while recording data from sensors at discrete locations, which are then compared to established safety limits developed by cadaveric testing. Due to the difference in compliance of cadaveric and ATD legs, the force dissipating characteristics of footwear, and the lack of direct measurement of injury risk to the foot and ankle, a novel instrumented insole was developed that could be applied equally to all specimens both during injury limit generation and during safety evaluation tests. An array of piezoresistive sensors were calibrated over a range of speeds using a pneumatic impacting apparatus, and then applied to the insole of a boot. The boot was subsequently tested and compared to loads measured using ankle and toe load cells in an ATD, and found to have an average error of 10%. The sensors also provided useful information regarding the force distribution across the sole of the foot during an impact, which may be used to develop regional injury criteria. This work has furthered the understanding of lower leg injury prediction and developed a tool that may be useful in developing accurate injury criteria in the future for the foot and lower leg.
- 29 November 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 141 (2)
A Force-Sensing Insole to Quantify Impact Loading to the Foot
Lower leg injuries commonly occur in frontal automobile collisions, and are associated with high disability rates. Accurate methods to predict these injuries must be developed to facilitate the testing and improvement of vehicle safety systems. Anthropomorphic test devices (ATDs) are often used to assess injury risk by mimicking the behavior of the human body in a crash while recording data from sensors at discrete locations, which are then compared to established safety limits developed by cadaveric testing. Due to the difference in compliance of cadaveric and ATD legs, the force dissipating characteristics of footwear, and the lack of direct measurement of injury risk to the foot and ankle, a novel instrumented insole was developed that could be applied equally to all specimens both during injury limit generation and during safety evaluation tests. An array of piezoresistive sensors were calibrated over a range of speeds using a pneumatic impacting apparatus, and then applied to the insole of a boot. The boot was subsequently tested and compared to loads measured using ankle and toe load cells in an ATD, and found to have an average error of 10%. The sensors also provided useful information regarding the force distribution across the sole of the foot during an impact, which may be used to develop regional injury criteria. This work has furthered the understanding of lower leg injury prediction and developed a tool that may be useful in developing accurate injury criteria in the future for the foot and lower leg.