Cheryl E. Quenneville
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheryl E. Quenneville has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Fatemeh Jazinizadeh
Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada
5 shared publications- Julia E. de Lange
School of Biomedical Engineering, McMaster University , Hamilton, ON L8S 4L8, Canada
4 shared publications - Alberto A. Martinez
Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada
2 shared publications Ali Ammar
School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
2 shared publicationsAryen Shakib
School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
2 shared publicationsAvery B. Chakravarty
Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada
2 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 10 (8)
Development of an Automated Landmarking Tool for the Femur in DXA Scans Using Contour-Based Image Analysis
Osteoporosis is a skeletal disease that significantly increases fracture risk and imposes a growing public health and economic burden. Notably, hip fractures are associated with high mortality, long-term disability, and loss of independence. When evaluating osteoporosis and estimating fracture risk, dual-energy X-ray absorptiometry (DXA) is commonly used to determine the bone mineral density. To capture geometrical morphology from these DXA scans as factors in fracture risk prediction, landmarking around the femur is conducted manually around the region of interest. However, this process is labor-intensive and prone to variability. This study presents the development of a fully automated femoral landmarking tool that integrates a U-Net convolutional neural network for femur contour segmentation with a geometric algorithm for consistent landmark placement. A heterogeneous dataset of 555 DXA scans was used to train and evaluate the U-Net model, achieving a pixel-wise accuracy of 97.55%, an Intersection over Union (IoU) of 91.55%, and a Dice coefficient of 95.56% on the test set. When incorporated into a Statistical Shape and Appearance Modeling (SSAM) framework for fracture risk prediction, predictions using the automatically generated landmarks achieved a test AUC of 0.831 (95% CI: 0.698–0.965), compared with 0.780 (95% CI: 0.635–0.925) for manual landmarks; a paired DeLong test showed no significant difference (p = 0.53), indicating a comparable performance. The proposed pipeline produces anatomically relevant, reproducible landmarks and supports fracture prediction performance similar to manual methods. It presents a scalable and objective solution for morphometric analysis in DXA imaging.
- 19 June 2026
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 10 (8)
Open AccessDevelopment of an Automated Landmarking Tool for the Femur in DXA Scans Using Contour-Based Image Analysis
Osteoporosis is a skeletal disease that significantly increases fracture risk and imposes a growing public health and economic burden. Notably, hip fractures are associated with high mortality, long-term disability, and loss of independence. When evaluating osteoporosis and estimating fracture risk, dual-energy X-ray absorptiometry (DXA) is commonly used to determine the bone mineral density. To capture geometrical morphology from these DXA scans as factors in fracture risk prediction, landmarking around the femur is conducted manually around the region of interest. However, this process is labor-intensive and prone to variability. This study presents the development of a fully automated femoral landmarking tool that integrates a U-Net convolutional neural network for femur contour segmentation with a geometric algorithm for consistent landmark placement. A heterogeneous dataset of 555 DXA scans was used to train and evaluate the U-Net model, achieving a pixel-wise accuracy of 97.55%, an Intersection over Union (IoU) of 91.55%, and a Dice coefficient of 95.56% on the test set. When incorporated into a Statistical Shape and Appearance Modeling (SSAM) framework for fracture risk prediction, predictions using the automatically generated landmarks achieved a test AUC of 0.831 (95% CI: 0.698–0.965), compared with 0.780 (95% CI: 0.635–0.925) for manual landmarks; a paired DeLong test showed no significant difference (p = 0.53), indicating a comparable performance. The proposed pipeline produces anatomically relevant, reproducible landmarks and supports fracture prediction performance similar to manual methods. It presents a scalable and objective solution for morphometric analysis in DXA imaging.
- 2 May 2026
- Published by Springer Nature in Current Osteoporosis Reports
- Vol. 24 (1) , 18
The Use of Statistical Shape and Appearance Modelling for Predicting Osteoporotic Fracture Risk
Purpose of Review Osteoporotic fractures remain a major cause of morbidity and mortality worldwide. Current clinical assessment metrics (e.g., bone mineral density) are limited in their ability to identify fracture risk and bone strength. Statistical Shape and Appearance Modelling (SSAM) offers a method to quantify anatomical geometry and density patterns. This review examines advancements in SSAM for osteoporosis research. Recent Findings Recent literature demonstrates that SSAM can capture detailed bone geometry and internal density distribution. Increasingly, these models are combined with computational analytics, including finite element analysis and machine learning, to assess the mechanical and structural behavior of bone. Summary SSAM provides a robust quantitative framework for bone research. Notably, SSAM is used to reconstruct 3D subjects from clinical 2D images for biomechanical evaluation. Although clinical adoption remains limited by generalizability, the advancement of deep learning and complex SSAM pipelines supports its potential for osteoporosis screening and fracture risk prediction.
- 2 May 2026
- Published by Springer Nature in Current Osteoporosis Reports
- Vol. 24 (1) , 18
The Use of Statistical Shape and Appearance Modelling for Predicting Osteoporotic Fracture Risk
Purpose of Review Osteoporotic fractures remain a major cause of morbidity and mortality worldwide. Current clinical assessment metrics (e.g., bone mineral density) are limited in their ability to identify fracture risk and bone strength. Statistical Shape and Appearance Modelling (SSAM) offers a method to quantify anatomical geometry and density patterns. This review examines advancements in SSAM for osteoporosis research. Recent Findings Recent literature demonstrates that SSAM can capture detailed bone geometry and internal density distribution. Increasingly, these models are combined with computational analytics, including finite element analysis and machine learning, to assess the mechanical and structural behavior of bone. Summary SSAM provides a robust quantitative framework for bone research. Notably, SSAM is used to reconstruct 3D subjects from clinical 2D images for biomechanical evaluation. Although clinical adoption remains limited by generalizability, the advancement of deep learning and complex SSAM pipelines supports its potential for osteoporosis screening and fracture risk prediction.
- Open Access
- 31 October 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Development of a novel test surrogate for evaluating material protection against hockey puck impacts to the neck and clavicle
During ice hockey, pucks travel at high speeds and have the potential to cause substantial injury. The neck and torso are vulnerable locations where protective materials could mitigate impacts and reduce injury. Currently, neck guards are tested solely for cut protection, while no known standards exist for chest protection. To assess products and materials, a novel test surrogate was required with realistic body geometry (for product mounting) and stiffness (reflecting body compliance). The neck and clavicle were instrumented, and hockey puck impacts were applied to each in an unpadded condition, as well as with eight foams and three commercial neck guards in place. Protection of each material was quantified as the reduction in force relative to the unpadded condition. The greatest force reduction with a foam was 42%–46% (neck-clavicle), supporting its potential use in equipment. Only one of the commercial neck guards provided impact resistance (39% force reduction, vs 4%–6% in the others). Without injury tolerance data for the neck, it is unknown if the materials would have prevented injury; none reduced load below the reported fracture tolerance of the clavicle. This test surrogate and investigation may inform the future development of standards for improved hockey equipment design and evaluation.
- 31 October 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Open AccessDevelopment of a novel test surrogate for evaluating material protection against hockey puck impacts to the neck and clavicle
During ice hockey, pucks travel at high speeds and have the potential to cause substantial injury. The neck and torso are vulnerable locations where protective materials could mitigate impacts and reduce injury. Currently, neck guards are tested solely for cut protection, while no known standards exist for chest protection. To assess products and materials, a novel test surrogate was required with realistic body geometry (for product mounting) and stiffness (reflecting body compliance). The neck and clavicle were instrumented, and hockey puck impacts were applied to each in an unpadded condition, as well as with eight foams and three commercial neck guards in place. Protection of each material was quantified as the reduction in force relative to the unpadded condition. The greatest force reduction with a foam was 42%–46% (neck-clavicle), supporting its potential use in equipment. Only one of the commercial neck guards provided impact resistance (39% force reduction, vs 4%–6% in the others). Without injury tolerance data for the neck, it is unknown if the materials would have prevented injury; none reduced load below the reported fracture tolerance of the clavicle. This test surrogate and investigation may inform the future development of standards for improved hockey equipment design and evaluation.
- Open Access
- 1 March 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 239 (3) , 308-320
The effect of file type and DXA protocol on an image processing fracture risk prediction tool
Osteoporosis, a common bone disease in older adults, is associated with low bone mineral density (BMD) and an increased risk of fractures. While fracture risk is often assessed using T-scores derived from dual-energy X-ray absorptiometry (DXA) scans, these measures are not fully effective in identifying individuals at greatest risk. To address this, a Statistical Shape and Appearance Modeling (SSAM) tool was previously developed to analyze femur shape and BMD distribution and demonstrated superior fracture risk prediction compared to T-scores using hip DXA scans exported in JPG format. The present study aimed to evaluate whether changes in DXA-imaging protocol (hip protocol vs. High-Definition Instant Vertebral Assessment (IVA-HD)) may influence the image and the SSAM tool’s fracture risk predictions. The effect of image file type (JPG vs. PNG) was also explored, as native formats such as Digital Imaging and Communications in Medicine (DICOM) cannot be readily exported or saved in large databases. DXA scans from 36 subjects and seven cadaveric femurs were analyzed across four imaging conditions (file types and imaging protocols). Structural Similarity Index Measures (SSIM) quantified image differences, and Bland-Altman plots assessed agreement in fracture risk predictions. Minimal differences were found in SSAM tool outputs across protocols and file types. Higher-resolution scans (IVA-HD) and lossless file types (PNG) did not improve the accuracy of risk predictions compared to the standard hip protocol in JPG format. These findings suggest that the SSAM tool is robust to variations in imaging conditions, supporting its use with standard DXA imaging protocols and file formats.
- 1 March 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 239 (3) , 308-320
Open AccessThe effect of file type and DXA protocol on an image processing fracture risk prediction tool
Osteoporosis, a common bone disease in older adults, is associated with low bone mineral density (BMD) and an increased risk of fractures. While fracture risk is often assessed using T-scores derived from dual-energy X-ray absorptiometry (DXA) scans, these measures are not fully effective in identifying individuals at greatest risk. To address this, a Statistical Shape and Appearance Modeling (SSAM) tool was previously developed to analyze femur shape and BMD distribution and demonstrated superior fracture risk prediction compared to T-scores using hip DXA scans exported in JPG format. The present study aimed to evaluate whether changes in DXA-imaging protocol (hip protocol vs. High-Definition Instant Vertebral Assessment (IVA-HD)) may influence the image and the SSAM tool’s fracture risk predictions. The effect of image file type (JPG vs. PNG) was also explored, as native formats such as Digital Imaging and Communications in Medicine (DICOM) cannot be readily exported or saved in large databases. DXA scans from 36 subjects and seven cadaveric femurs were analyzed across four imaging conditions (file types and imaging protocols). Structural Similarity Index Measures (SSIM) quantified image differences, and Bland-Altman plots assessed agreement in fracture risk predictions. Minimal differences were found in SSAM tool outputs across protocols and file types. Higher-resolution scans (IVA-HD) and lossless file types (PNG) did not improve the accuracy of risk predictions compared to the standard hip protocol in JPG format. These findings suggest that the SSAM tool is robust to variations in imaging conditions, supporting its use with standard DXA imaging protocols and file formats.
- Open Access
- 7 January 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
- Vol. 240 (3) , 693-702
Investigation of tibia and fibula fracture risk during football impacts using finite element human body models
Injuries in football are prevalent, and while shin guards reduce these, current test standards are primarily intended to evaluate contusion risk rather than more serious outcomes such as fractures. In this study, a finite element human body model was used to assess fracture risk in the lower leg subjected to conditions representative of football impacts. Various impactor shapes, impact locations and orientations were explored to identify conditions where fractures may be more likely to occur (based on element strain) and the associated force and bending moment. The lower leg was most susceptible to fractures at the 35% tibial height. Fractures occurred most frequently from the anterolateral direction, resulting in fibula injuries. In terms of geometry, the stud impactors were the most effective at inducing fractures and fracture was highly sensitive to bone alignment. Force to fracture ranged from 1595 to 2612 N. Susceptibility to fractures was influenced by the cross-sectional area of the bone, as well as the soft tissue thickness, with increased force attenuation associated with greater tissue thicknesses. This study showed various parameters affect the fracture tolerance of the lower leg, and identified the impact energies required to induce fractures, to better inform test standards for protective equipment.
- 7 January 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
- Vol. 240 (3) , 693-702
Open AccessInvestigation of tibia and fibula fracture risk during football impacts using finite element human body models
Injuries in football are prevalent, and while shin guards reduce these, current test standards are primarily intended to evaluate contusion risk rather than more serious outcomes such as fractures. In this study, a finite element human body model was used to assess fracture risk in the lower leg subjected to conditions representative of football impacts. Various impactor shapes, impact locations and orientations were explored to identify conditions where fractures may be more likely to occur (based on element strain) and the associated force and bending moment. The lower leg was most susceptible to fractures at the 35% tibial height. Fractures occurred most frequently from the anterolateral direction, resulting in fibula injuries. In terms of geometry, the stud impactors were the most effective at inducing fractures and fracture was highly sensitive to bone alignment. Force to fracture ranged from 1595 to 2612 N. Susceptibility to fractures was influenced by the cross-sectional area of the bone, as well as the soft tissue thickness, with increased force attenuation associated with greater tissue thicknesses. This study showed various parameters affect the fracture tolerance of the lower leg, and identified the impact energies required to induce fractures, to better inform test standards for protective equipment.
- 13 May 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-29
Injury Risk Functions for the Midsized Male Wrist and Elbow as a Result of Behind Shield Blunt Trauma
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield deflecting or absorbing a projectile and deforming toward the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user. Two vulnerable locations along the upper extremity were investigated—the wrist and elbow—on eight postmortem human subjects (PMHS) using a pneumatic impacting apparatus for investigating the fracture threshold as a result of behind shield blunt trauma (BSBT). Impacting parameters were established by subjecting an augmented WorldSID anthropomorphic test device (ATD) positioned behind a ballistic shield to ballistic impacts. These data were used to form the impact parameters applied to PMHS, where the wrist most frequently fractured at the distal radius and the elbow most frequently fractured at the radial head. The fracture threshold for the wrist was 5663±1386 N (mean±standard deviation), higher than the elbow at 4765±894 N (though not significantly, p = 0.15). The failure impact velocity for wrist impacts was 17.7±2.1 m/s, while for the elbow, the failure impact velocity was 19.5±0.9 m/s. An approximate 10% risk of fracture threshold was identified on the modified WorldSID ATD (no flesh analogue included) to inform future protective standards.
- 13 May 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-29
Injury Risk Functions for the Midsized Male Wrist and Elbow as a Result of Behind Shield Blunt Trauma
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield deflecting or absorbing a projectile and deforming toward the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user. Two vulnerable locations along the upper extremity were investigated—the wrist and elbow—on eight postmortem human subjects (PMHS) using a pneumatic impacting apparatus for investigating the fracture threshold as a result of behind shield blunt trauma (BSBT). Impacting parameters were established by subjecting an augmented WorldSID anthropomorphic test device (ATD) positioned behind a ballistic shield to ballistic impacts. These data were used to form the impact parameters applied to PMHS, where the wrist most frequently fractured at the distal radius and the elbow most frequently fractured at the radial head. The fracture threshold for the wrist was 5663±1386 N (mean±standard deviation), higher than the elbow at 4765±894 N (though not significantly, p = 0.15). The failure impact velocity for wrist impacts was 17.7±2.1 m/s, while for the elbow, the failure impact velocity was 19.5±0.9 m/s. An approximate 10% risk of fracture threshold was identified on the modified WorldSID ATD (no flesh analogue included) to inform future protective standards.
- 8 April 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (9) , 1-35
Estimation of Injury Limits at Vulnerable Impact Locations Along the Forearm Via THUMS AM50 Finite Element Model at Airbag Loading Rates
Side and frontal airbag deployment represents the main injury mechanism to the upper extremity during automotive collisions. Previous dynamic injury limit research has been limited to testing the forearm at either the assumed most vulnerable location to fracture, the distal 1/3rd, or the midpoint. Studies have varied the surface to which impacts were applied, with no clear consensus on the site of greatest vulnerability. The unpredictability of airbag impact location, especially with altered hand positioning, limits the effectiveness of existing forearm injury limits determined from impacts at only one location. The current study quantified the effect of impacts at alternative locations on injury risk along the forearm using the THUMS FE model. Airbag-level impacts were simulated along the forearm on all four anatomical surfaces. Results showed the distal 1/3rd is not the most vulnerable location (for any side), indicating forearm fracture is not solely driven by area moment of inertia (as previously assumed). The posterior forearm was the weakest, suggesting that current test standards underestimate the fracture risk of the forearm. Linear regression models showed strong correlation between forearm fracture risk and bone geometry (cross-sectional area and area moment of inertia) as well as soft-tissue depth, potentially providing the ability to predict forearm injury tolerances for any location or forearm size. This study demonstrated the forearm's vulnerability to fracture from airbag deployments, indicating the need for safety systems to better address injury mechanisms for the upper limb to effectively protect drivers.
- 8 April 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (9) , 1-35
Estimation of Injury Limits at Vulnerable Impact Locations Along the Forearm Via THUMS AM50 Finite Element Model at Airbag Loading Rates
Side and frontal airbag deployment represents the main injury mechanism to the upper extremity during automotive collisions. Previous dynamic injury limit research has been limited to testing the forearm at either the assumed most vulnerable location to fracture, the distal 1/3rd, or the midpoint. Studies have varied the surface to which impacts were applied, with no clear consensus on the site of greatest vulnerability. The unpredictability of airbag impact location, especially with altered hand positioning, limits the effectiveness of existing forearm injury limits determined from impacts at only one location. The current study quantified the effect of impacts at alternative locations on injury risk along the forearm using the THUMS FE model. Airbag-level impacts were simulated along the forearm on all four anatomical surfaces. Results showed the distal 1/3rd is not the most vulnerable location (for any side), indicating forearm fracture is not solely driven by area moment of inertia (as previously assumed). The posterior forearm was the weakest, suggesting that current test standards underestimate the fracture risk of the forearm. Linear regression models showed strong correlation between forearm fracture risk and bone geometry (cross-sectional area and area moment of inertia) as well as soft-tissue depth, potentially providing the ability to predict forearm injury tolerances for any location or forearm size. This study demonstrated the forearm's vulnerability to fracture from airbag deployments, indicating the need for safety systems to better address injury mechanisms for the upper limb to effectively protect drivers.
- Open Access
- 31 March 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 154, 106534
Region partitioning of articular cartilage with streaming-potential-based parameters and indentation maps
- 31 March 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 154, 106534
Open AccessRegion partitioning of articular cartilage with streaming-potential-based parameters and indentation maps
- 7 February 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (3) , 1-31
Evaluation of an Elastomeric Honeycomb Bicycle Helmet Design to Mitigate Head Kinematics in Oblique Impacts
Head impacts in bicycle accidents are typically oblique to the impact surface and transmit both normal and tangential forces to the head, causing linear and rotational head kinematics, respectively. Traditional expanded polystyrene (EPS) foam bicycle helmets are effective at preventing many head injuries, especially skull fractures and severe traumatic brain injuries (TBIs) (primarily from normal contact forces). However, the incidence of concussion from collisions (primarily from rotational head motion) remains high, indicating need for enhanced protection. An elastomeric honeycomb helmet design is proposed herein as an alternative to EPS foam to improve TBI protection and be potentially reusable for multiple impacts, and tested using a twin-wire drop tower. Small-scale normal and oblique impact tests showed honeycomb had lower oblique strength than EPS foam, beneficial for diffuse TBI protection by permitting greater shear deformation and had the potential to be reusable. Honeycomb helmets were developed based on the geometry of an existing EPS foam helmet, prototypes were three-dimensional-printed with thermoplastic polyurethane and full-scale flat and oblique drop tests were performed. In flat impacts, honeycomb helmets resulted in a 34% higher peak linear acceleration and 7% lower head injury criteria (HIC15) than EPS foam helmets. In oblique tests, honeycomb helmets resulted in a 30% lower HIC15 and 40% lower peak rotational acceleration compared to EPS foam helmets. This new helmet design has the potential to reduce the risk of TBI in a bicycle accident, and as such, reduce its social and economic burden. Also, the honeycomb design showed potential to be effective for repetitive impact events without the need for replacement, offering benefits to consumers.
- 7 February 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (3) , 1-31
Evaluation of an Elastomeric Honeycomb Bicycle Helmet Design to Mitigate Head Kinematics in Oblique Impacts
Head impacts in bicycle accidents are typically oblique to the impact surface and transmit both normal and tangential forces to the head, causing linear and rotational head kinematics, respectively. Traditional expanded polystyrene (EPS) foam bicycle helmets are effective at preventing many head injuries, especially skull fractures and severe traumatic brain injuries (TBIs) (primarily from normal contact forces). However, the incidence of concussion from collisions (primarily from rotational head motion) remains high, indicating need for enhanced protection. An elastomeric honeycomb helmet design is proposed herein as an alternative to EPS foam to improve TBI protection and be potentially reusable for multiple impacts, and tested using a twin-wire drop tower. Small-scale normal and oblique impact tests showed honeycomb had lower oblique strength than EPS foam, beneficial for diffuse TBI protection by permitting greater shear deformation and had the potential to be reusable. Honeycomb helmets were developed based on the geometry of an existing EPS foam helmet, prototypes were three-dimensional-printed with thermoplastic polyurethane and full-scale flat and oblique drop tests were performed. In flat impacts, honeycomb helmets resulted in a 34% higher peak linear acceleration and 7% lower head injury criteria (HIC15) than EPS foam helmets. In oblique tests, honeycomb helmets resulted in a 30% lower HIC15 and 40% lower peak rotational acceleration compared to EPS foam helmets. This new helmet design has the potential to reduce the risk of TBI in a bicycle accident, and as such, reduce its social and economic burden. Also, the honeycomb design showed potential to be effective for repetitive impact events without the need for replacement, offering benefits to consumers.
- 21 December 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (3) , 707-718
Injury Risk for the Hand and Forearm Under Loading Representative of Behind Shield Blunt Trauma
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield absorbing energy from a projectile and deforming towards the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user and may cause injury through behind armour blunt trauma (BABT) mechanisms. Post-mortem human subject (PMHS) responses are critical to identify the injury risk in these high-rate scenarios and are used to quantify the injury tolerance. Two vulnerable locations along the upper extremity were investigated—the hand and forearm—using eight PMHS to identify the fracture threshold resulting from shield BABT loading conditions. Impacts delivered to the hand at 16.4 ± 0.8 m/s resulted in failure loads of 3818 ± 897 N, whilst the forearm impacts delivered at a similar velocity of 16.9 ± 1.9 m/s had lower failure loads at 3011 ± 656 N. The corresponding 10% risk of hand and forearm fractures (as measured on a modified WorldSID Anthropomorphic Test Device) were identified as 11.0 kN and 8.1 kN, respectively, which should be used when evaluating future designs of composite ballistic shields. This study is the first known investigation of the upper extremity to this high loading rate scenario and provides the foundation for future biomechanical research in the area of behind shield blunt trauma.
- 21 December 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (3) , 707-718
Injury Risk for the Hand and Forearm Under Loading Representative of Behind Shield Blunt Trauma
Ballistic shields protect users from a variety of threats, including projectiles. Shield back-face deformation (BFD) is the result of the shield absorbing energy from a projectile and deforming towards the user. Back-face deformation can result in localized blunt loading to the upper extremity, where the shield is supported by the user and may cause injury through behind armour blunt trauma (BABT) mechanisms. Post-mortem human subject (PMHS) responses are critical to identify the injury risk in these high-rate scenarios and are used to quantify the injury tolerance. Two vulnerable locations along the upper extremity were investigated—the hand and forearm—using eight PMHS to identify the fracture threshold resulting from shield BABT loading conditions. Impacts delivered to the hand at 16.4 ± 0.8 m/s resulted in failure loads of 3818 ± 897 N, whilst the forearm impacts delivered at a similar velocity of 16.9 ± 1.9 m/s had lower failure loads at 3011 ± 656 N. The corresponding 10% risk of hand and forearm fractures (as measured on a modified WorldSID Anthropomorphic Test Device) were identified as 11.0 kN and 8.1 kN, respectively, which should be used when evaluating future designs of composite ballistic shields. This study is the first known investigation of the upper extremity to this high loading rate scenario and provides the foundation for future biomechanical research in the area of behind shield blunt trauma.