A Histopathologic Study of Orbital Implant Vascularization
Authors:
- 1 January 2009
- journal article
- research article
- Published by Taylor & Francis in Orbit
- Vol. 28 (1) , 50-57
Abstract
Purpose: To histopathologically assess the extent and pattern of vascularization of explanted porous polyethylene (PP) and hyrdoxyapatite (HA) orbital implants. To compare the vascularization in PP implants harvested after enucleation versus after evisceration. Methods: This is a comparative case series of six orbital implants explanted between 11 months and 5 years and 4 months post implantation. The implants were subjected to histopathological examination with various stains, after complete decalcification. Results: There were 2 post evisceration, 3 post enucleation and 1 secondary implant. The size of the implants varied from 18 to 23 mm diameter. The reason for explantation was exposure in all the 6 cases with additional infection in 2 cases. Histopathology revealed complete vascularization up to the core of the implant in all the cases. There was evidence of chronic inflammation within all the explanted specimens. Acute inflammation was present at the site of exposure in four of the implants. Three of these implants had additional evidence of necrosis. Two cases with clinically evident infection had Gram positive cocci within the implant. Foreign-body type giant-cells, melanophages and haemosiderin laden macrophages were also observed. Eviscerated specimens showed scleral remodelling and thickening. Conclusion: All the implants were vascularized up to the core. There was histologic evidence of chronic inflammation in all the explanted implants possibly indicating the foreign nature of the implant material. The sclera did not impede vascularization of the implants in eviscerated specimens. We found no difference in the degree of vascularization of the implant in enucleated versus eviscerated implants.Keywords
This publication has 30 references indexed in Scilit:
- Porous Polyethylene (Medpor) Orbital Implants with Primary Acellular Dermis Patch GraftsOrbit, 2008
- Magnetic resonance imaging assessment of fibrovascular ingrowth into porous polyethylene orbital implantsClinical & Experimental Ophthalmology, 2006
- Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposureBritish Journal of Ophthalmology, 2004
- Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (medpor)11The authors have no proprietary interest in any of the materials used in this study.Ophthalmology, 2000
- The Safety and Applications of Acellular Human Dermal Allograft in Ophthalmic Plastic and Reconstructive SurgeryOphthalmic Plastic & Reconstructive Surgery, 2000
- Hydroxyapatite orbital implant: A light- and electron-microscopic and immunohistochemical studyOphthalmology, 1998
- Quantitative Measurement of Vascularization and Vascular Ingrowth Rate of Coralline Hydroxyapatite Ocular Implant by Tc-99m MDP Bone ImagingClinical Nuclear Medicine, 1995
- Hydroxyapatite Orbital Implant AbscessOphthalmic Plastic & Reconstructive Surgery, 1994
- Comparison of Fibrovascular Ingrowth into Hydroxyapatite and Porous Polyethylene Orbital ImplantsOphthalmic Plastic & Reconstructive Surgery, 1994
- Exposure Rate of Hydroxyapatite Spheres in the Anophthalmic SocketOphthalmic Plastic & Reconstructive Surgery, 1993