Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties
Open Access
- 23 January 2019
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (2) , 172-178
Abstract
Background and purpose — Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods — Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs). Results — 1-year maximum total point motion was lower for the cemented tibial components compared with the uncemented components (median = 0.31 mm [0.03–2.98] versus 0.63 mm [0.11–5.19] respectively, p < 0.001, mixed model). The change in migration from 1 to 2 years, however, was equivalent for cemented and uncemented components (mean [SD] 0.06 mm [0.19] and 0.07 mm [0.27] mm respectively, p = 0.6, mixed model). Interpretation — These findings suggest that current thresholds of acceptable migration at 1 year may be better optimized by considering cemented and uncemented tibial components separately as higher early migration of uncemented components was not associated with decreased stability from 1 to 2 years.Keywords
This publication has 37 references indexed in Scilit:
- Early migration of tibial components is associated with late revisionActa Orthopaedica, 2012
- The beneficial effect of hydroxyapatite lastsActa Orthopaedica, 2012
- Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years—measured with radiostereometric analysisActa Orthopaedica, 2011
- Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber meshActa Orthopaedica, 2011
- Preoperative gait patterns and BMI are associated with tibial component migrationActa Orthopaedica, 2010
- Uncemented HA-coated Implant is the Optimum Fixation for TKA in the Young PatientClinical Orthopaedics and Related Research, 2006
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- Editorial Comments: Introducing New Technology: A Stepwise AlgorithmSpine, 2000
- The stability of three different cementless tibial components: A randomized radiostereometric study in 45 knee arthroplasty patientsActa Orthopaedica, 1995
- Roentgen stereophotogrammetryActa Orthopaedica, 1989