Elise K. Laende
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elise K. Laende has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
C Glen Richardson
Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
2 shared publicationsMichael J Dunbar
Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
2 shared publicationsAllan W. Hennigar
1 shared publicationC. G. Richardson
Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
1 shared publicationEdward R Valstar
E Department of Orthopedics , Leiden University Medical Center , Leiden , The Netherlands
1 shared publication- Janie L. Astephen Wilson
School of Biomedical Engineering, Dalhousie University, Halifax, NS, Canada
1 shared publication
Latest Publications
- 15 October 2019
- Published by SAGE Publications in HIP International
- Vol. 31 (2) , 191-195
Prospective clinical study using radiostereometric analysis (RSA) to evaluate fixation of a modular cemented polished femoral stem
Background: The long-term clinical success of cemented polished tapered femoral components has been demonstrated in prospective as well as registry studies. This stem design type has also been well studied with radiostereometric analysis (RSA) and provides a standard to evaluate alternative designs of polished tapered cemented femoral components. This prospective study evaluates the subsidence of a polished cemented stem with a modular neck design utilising RSA. Methods: 26 patients were prospectively enrolled in the study and 23 were available for RSA analysis at 2 years. Results: The average subsidence of the femoral implant was 1.1 mm (SD 0.4 mm) at 2 years post operation. There were no revisions in this group, specifically no failures of the modular stem-neck design as has been seen with other implants. Conclusions: The RSA subsidence pattern at 2 years of this cemented femoral stem is similar to other successful designs with long-term follow-up. The implications over time of stem neck modularity for cemented polished tapered femoral components requires further evaluation.
- 15 October 2019
- Published by SAGE Publications in HIP International
- Vol. 31 (2) , 191-195
Prospective clinical study using radiostereometric analysis (RSA) to evaluate fixation of a modular cemented polished femoral stem
Background: The long-term clinical success of cemented polished tapered femoral components has been demonstrated in prospective as well as registry studies. This stem design type has also been well studied with radiostereometric analysis (RSA) and provides a standard to evaluate alternative designs of polished tapered cemented femoral components. This prospective study evaluates the subsidence of a polished cemented stem with a modular neck design utilising RSA. Methods: 26 patients were prospectively enrolled in the study and 23 were available for RSA analysis at 2 years. Results: The average subsidence of the femoral implant was 1.1 mm (SD 0.4 mm) at 2 years post operation. There were no revisions in this group, specifically no failures of the modular stem-neck design as has been seen with other implants. Conclusions: The RSA subsidence pattern at 2 years of this cemented femoral stem is similar to other successful designs with long-term follow-up. The implications over time of stem neck modularity for cemented polished tapered femoral components requires further evaluation.
- 1 July 2019
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 101-B (7_Supple_C) , 55-60
Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties
Aims: Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. Patients and Methods: Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components. Results: Migration at one year and two years was significantly correlated with long-term migration (p < 0.001). Median migration at the long-term follow-up was 0.6 mm (maximum total point motion; interquartile range (IQR) 0.4 to 0.9) for the cemented group and 0.6 mm (IQR 0.3 to 1.1) for the cementless group with no difference between groups (p = 0.99). Inducible displacement was significantly lower for the cementless components (p < 0.001). Conclusion: Long-term migration was strongly correlated with two-year migration. Although long-term migration was not different for cemented or cementless tibial components, inducible displacement at the long-term visit was significantly lower for these cementless components, suggesting superior fixation. These findings support the predictive value of short-term migration in determining long-term fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):55–60
- 1 July 2019
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 101-B (7_Supple_C) , 55-60
Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties
Aims: Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. Patients and Methods: Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components. Results: Migration at one year and two years was significantly correlated with long-term migration (p < 0.001). Median migration at the long-term follow-up was 0.6 mm (maximum total point motion; interquartile range (IQR) 0.4 to 0.9) for the cemented group and 0.6 mm (IQR 0.3 to 1.1) for the cementless group with no difference between groups (p = 0.99). Inducible displacement was significantly lower for the cementless components (p < 0.001). Conclusion: Long-term migration was strongly correlated with two-year migration. Although long-term migration was not different for cemented or cementless tibial components, inducible displacement at the long-term visit was significantly lower for these cementless components, suggesting superior fixation. These findings support the predictive value of short-term migration in determining long-term fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):55–60
- Open Access
- 23 January 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (2) , 172-178
Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties
Background and purpose — Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods — Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs). Results — 1-year maximum total point motion was lower for the cemented tibial components compared with the uncemented components (median = 0.31 mm [0.03–2.98] versus 0.63 mm [0.11–5.19] respectively, p < 0.001, mixed model). The change in migration from 1 to 2 years, however, was equivalent for cemented and uncemented components (mean [SD] 0.06 mm [0.19] and 0.07 mm [0.27] mm respectively, p = 0.6, mixed model). Interpretation — These findings suggest that current thresholds of acceptable migration at 1 year may be better optimized by considering cemented and uncemented tibial components separately as higher early migration of uncemented components was not associated with decreased stability from 1 to 2 years.
- 23 January 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (2) , 172-178
Open AccessEquivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties
Background and purpose — Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods — Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs). Results — 1-year maximum total point motion was lower for the cemented tibial components compared with the uncemented components (median = 0.31 mm [0.03–2.98] versus 0.63 mm [0.11–5.19] respectively, p < 0.001, mixed model). The change in migration from 1 to 2 years, however, was equivalent for cemented and uncemented components (mean [SD] 0.06 mm [0.19] and 0.07 mm [0.27] mm respectively, p = 0.6, mixed model). Interpretation — These findings suggest that current thresholds of acceptable migration at 1 year may be better optimized by considering cemented and uncemented tibial components separately as higher early migration of uncemented components was not associated with decreased stability from 1 to 2 years.
- 21 January 2019
- Published by Morressier GmbH
1737 - Ten Year Migration and Inducible Displacement of Cemented and Uncemented Tibial Components in Total Knee Arthroplasty
INTRODUCTION: Studies of implant migration measured with radiostereometric analysis (RSA) have typically focused on early migration in the first |
- 21 January 2019
- Published by Morressier GmbH
1737 - Ten Year Migration and Inducible Displacement of Cemented and Uncemented Tibial Components in Total Knee Arthroplasty
INTRODUCTION: Studies of implant migration measured with radiostereometric analysis (RSA) have typically focused on early migration in the first |
- 1 October 2009
- Published by Elsevier in Journal of Biomechanics
- Vol. 42 (14) , 2387-2393
Implementation and validation of an implant-based coordinate system for RSA migration calculation
- 1 October 2009
- Published by Elsevier in Journal of Biomechanics
- Vol. 42 (14) , 2387-2393
Implementation and validation of an implant-based coordinate system for RSA migration calculation